  • Page 1 取扱説明書 Instruction Manual 使用说明书 취급설명서 CL-SML008...
  • Page 2 Thank you for choosing this product ● Please read this instruction manual beforehand in order to use it properly. Then use the device safely. ● Please keep this instruction manual with great care. ● When receiving the warranty card from the dealer, please ensure and confirm details such as “Date of Purchase, Shop Name”...
  • Page 3: Table Of Contents

    Table of Contents Features of this product 2 Operating procedures Attention for the usage Safety Measures (Please comply) Full set of product content and name of each part How to charge How to use Description of the recommended care Treatment modes Recommended treatment program Treatment 18...
  • Page 4: Features Of This Product

    Features of this product ® ZōGANKIN Treatment Care Radio frequency (1MHz)+High frequency EMS (30kHz) ZōGANKIN is original beauty-treatment technology of giving stimulation- with warming it. It harmonize two different technology, One is high frequen- cy thermal beauty method by RF(radio frequency) that repeat cycle 1 million per second, The other is exercise method to stimulate muscle by EMS frequency that repeat cycle thirty thousand per second.
  • Page 5: Operating Procedures

    Operating procedures Charge the device Cleansing of face(body) Apply the sonic aqua gel on area to be treated Power on the device Select treatment mode Select power level Place the device on area to be treated , then slowly slide the device ( refer to P 18-21 “Treatment”...
  • Page 6: Attention For The Usage

    Precautions while using Please read following instruction before use it. For“ZōGANKIN Treatment Care” and “Thermal treatmentcare” each part is treated once a day, not exceeding 3 minutes. ※Please avoid using if you don’ t feel well ※It may cause low temperature burn on your skin  if the device is left stationary on a particular point.   ...
  • Page 7: Safety Measures (Please Comply)

    Safety Measures (Please comply) To avoid personal injury and damage of properties, please be sure to comply with the following instructions ■ The following classifications explain the dangers or damages from improper use means if there is error in operation, Danger Danger mishandling is likely to result death.
  • Page 8 Warning ●Disconnect the adaptor when you clean the device. There is a risk of electric shock if it is not disconnected. ●Must plug in AC socket. There is a risk of electric shock and ignition. if you do not follow.  Obligated ●Please clean the device regularly to avoid dust on the plug and adaptor.
  • Page 9 Warning ●Do not use the following occurs or on the following parts Do not feel well Eye lids and around eyes Muscles experience extreme fatigue Ear and around ear When feeling extremely tired Nose and nasal bone under taking medicine or soft plaster Mouth and lip Scalp and forehead skins with scratch, diseases,...
  • Page 10 Warning ●Do not make alteration. Never try to disassemble or   fix the product by yourself. There is a risk of fire, electric shock and injury. Should Do not maintenance be required (such as battery replacement), disassemble please consult the dealer where this product was first purchased. ●Never use for purposes other than cosmetic purposes.
  • Page 11: Full Set Of Product Content And Name Of Each Part

    Unit components and the name of each parts Treatment head Protective cover EMS・EX output head×2 output head×4 Main device Neck cover Temperature sensor (Thermostat) Display UP button Power level DOWN button Treatment mode selector Power button Power on/off (long-press) Pause/Resume (short-press) Battery plug connection port Sonic aqua gel Battery plug...
  • Page 12 Instruction of the display Operation display Treatment mode Power level Timer Battery display Output Treatment mode The following icons show the Modes are switched eveytime treatment heads are under operation. you press the button. Power level Numbers are switched eveytime you press the button.
  • Page 13: How To Charge

    How to charge Please fully charge the devie when use it for the first time. (until charge indicator turns off) Plug the charger adaptor plug Plug connection into the plug connection. ① Charge plug Plug the charger adaptor ② into home AC socket. Home AC socket (100V-240V) Charging completes in 4 hours...
  • Page 14 Note ●Recommended charge temperature is 15 to 35 degree. If the ambient temperature is out of this range, it may take longer to complete charging or may not charge. ●Especially it may shorten the life of battery in low temperature, so that please follow the recommended temperature.
  • Page 15: How To Use

    How to use Prepare ① Take off metals like accessories and contact lenses (earrings, pierces, rings, bracelets, necklaces, and watches.) ② Wash your face. If you use it for body treatment, wipe your body. ③ On parts to be treated, thickly apply about 5g (about the size of an almond) of sonic aqua gel.
  • Page 16 Please select level 1 for the first time users and with sensitive skins and adjust the power level according to the state of the skin. Adjust EMS level 1 to 5 by pressing . As pressing from status, it shows and starts radio frequency treatment.
  • Page 17: Description Of The Recommended Care

    Recommended care Start treatment with your favorite care after preparation. RF+high frquency(90kHz) ■Thermal Treatment Care Warm up with radio frequency (1MHz) and thermal treatment with 90kHz high frequency. Slect power level   and start treatment ※Each part can be treated once per day, not exceeding 3 minutes. RF+high frquency EMS The thermal treatment care with 1MH and EMS mucsule exercise with 30kHz...
  • Page 18: Treatment Modes

    Treatment modes ZōGANKIN Treatment Care Warming the skin thoroughly Warmup (Soothing) 4 seconds 4 seconds 4 seconds 4 seconds Rearrange the warmed skin with EMS stimulation Smooth (Rearranging) 8 seconds 2 seconds 8 sedconds Contract muscule through firm EMS stimulation Slimming (Firming) 6 seconds...
  • Page 19: Recommended Treatment Program

    Recommended treatment program 1 week Recommended to those who would like to get intensive treatment result for a short time. Intensive program! Day 1-2 Warm up Thermal treatment care: STEP1 whole face 3minutes Warm up your face and smooth Day 3-4 Smoothing ZōGANKIN Treatment Care: STEP2...
  • Page 20: Treatment

    Treatment ●Never aim at centre of the throat, do not use  around the eyes or on eyelids. ●Never aim at the forehead and do not use on the head. ●When in use, avoid tooth fillings and false teeth. ●Never aim at elbows and knees, nor use on joints. Warning ●Limit on use: Once per day for each part  (not exceeding 3 minutes).
  • Page 21 Face Chin 3 minutes Place the device horizontally at the lower center of the chin. With curved motion and in the rhythm of 1, 2 seconds, slide the device from left to right and reverse. Cheek 3 minutes each side Place the device horizontally Place the device vertically to the corner of the lips.
  • Page 22 Body 3 minutes each side Abdomen 1 Slide along from side to rib cage. Abdomen 2 Slide from down in upward along rib cage to hypogastrium. Waist Slide from bottom in upward along the waistline. Hips Slide from down in upwad along the outer thigh at the bottom of the hips.
  • Page 23 3 minutes each side Upper Arm Place the device at the inner or outer upper arm, then slide it from elbow to the armpit. Chest Place the device at the armpit, then slide it toward below the collarbone. Thigh Place the device at the inner or outer thigh, then slide it from down in upward.
  • Page 24: After Treatment

    After treatment When maintenance is required, please ensure the device is power-off. If maintaining with wet-tissues or towels while the device is power-on, there is a risk of shock. ●If there is residual dirt, oil or gel on the thermostat, the thermal sensor will not be able to sense the temperature correctly, giving rise to risks of low temperature burns.
  • Page 25: How To Storage

    How to storage Do not place this product in the following environments. This product is a precision instrument that contains electronic components. Please do not expose this product to the following environments for safekeeping, otherwise it may result in poor operation or malfunction. In direct sunlight Dusty environment High temperature variance HIgh humidity variance In open fire...
  • Page 26: Cause Of Malfunction

    Cause of the troubles ●Do not dry the device with a dryer or fan heater. It may result in the deformation of parts or malfunction. ●Do not wash with water, drop into water, use in the watery areas. It may result in mulfunction. ●Do not place at the high temperature area.
  • Page 27 Product rated specifications and description Device ■Product Name: ZōGANKIN HYPER ■Model Type:CL-SML008 ■Dimensions:W57mm × D32mm × H168mm ■Weight:170g (with internal Li-ion rechargeable battery) ■Material of device: ABS resin, PC (Polycarbonate), Silicon rubber ■Material of treatment heads:Stainless Steel (SUS304) ■Timer:With automatic power-off function after 3 minutes Charger Adaptor ■Power Supply:AC 100-240V, 50/60Hz, 0.2A...
  • Page 28: Troublesshooting

    Troublesshooting If you experience trouble with the device, try the following solutions. Cannot power on Did not charge the device. Charge the device refer to P.11” How to charge” is pressed lightly and Long-press until it sounds “Beep” not properly pressed. and Power on the display.
  • Page 29 Cannot feel RF, will not warm up Pause button being Press to resume. pressed down. The temperature sensor in the center of treatment head senses skin temperature in range of The thermo stat function 40 degrees.Therefore, sudden temperature is working. chage will not happen.
  • Page 30: Q&A

    Q&A Feel muscle fatigue after using Temporary fatigue caused by exercising of muscles. Before the skin and muscle have recovered, please do not use. If the symptoms do not recover, please consult a doctor Thermal treatment care Press from level 0 in the stand-by status, set the level Most effective time of use Recommended is after taking a bath with warmed body.
  • Page 31 Do not use on the following parts Eyelids and around the eye area, ears and around the ears, nose and nasal bone, mouth and lips, scalp and forehead, adam’ s apple, with skin problems, when there are cuts, with sensitive skin,crest, lymphonodus, around heart, joints like a knees and elbows, mucosa.
  • Page 32: Repair

    Repair ●Warranty  The warranty is attached on the end of this manual.  Please make sure that you fill in the information about purchase d shop  and the date of purchase, and keep it  after you read the manual carefully.  The warranty period is 1 year after your purchase.  This warranty covers only the main body, the lithium battery and the charger adaptor, but not the attached gel and the other attachment.
  • Page 33 2. We will charge for repairing cost under these conditions. ① Break or damage because you use it for other purposes except for written purposes in the manual. ② Break or damage because of your unreasonable repairing or remodeling. ③ Break or damage because of storage places, transportation, or falling after your purchase.
  • Page 34 COPY 【ZōGANKIN HYPER Warranty】 This warranty promises free replacement of the device subject to within the specified period of warrenty term written in this manual P30, 31. Please find the intended purpose of personal information filled in by customers COPY in the back side of this manual.