READ AND SAVE THESE INSTRUCTIONS SAFETY PRECAUTIONS WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: • Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. •...
Page 3
1- The dust. 2- Humidity. 3- Chemical poluants and odors. The Epurair system has been specifically made to eliminate these poluants. • The humidity is evacuated by the exit on the outside of the unit. • The chemical poluants and odors are eliminated by the...
Epurair VRC-95 - Owner’s manual PAGE 4 OPERATION The Epurair has been designed for continuous 24 hours a day ventilation. Your system fas been installed with a remote humidistat control. This should be set in the green zone between 35 % and 45 % at all times.
Page 5
ON position for a few hours. ANNUAL MAINTENANCE KIT The kit for your annual VRC-95 contains everything you need to maintain your equipment for one year. To order the kit annually, contact your installer or contact our customer service at 1 800-205-1108 to know the supplier nearest you.
A very humid house may need more ventilation, so you can adjust the unit by turning the buttons outside the VRC-95 as follow. Blue Top button controls ventilation mode Used when you need to close machine completerly.
Page 7
Epurair VRC-95 - Owner’s manual PAGE 7 The bottom blue button controls fresh air quantity 1 2 3 4 5 The installator has programmed the unit according to your house needs. The numbers 1, 2, 3, 4, 5, represent the number of rooms in your house.
For your convenience, an annual HRV filter kit (EPURAIR ANCKITVRC) contains everything you need. Your Epurair is equipped with 2 filters to protect the heat recovery core and eliminates odors. It is recommended to replace tese filters every 6 months and to keep your heat recovery core clean.
Page 9
Epurair VRC-95 - Owner’s manual PAGE 9 CLEANING THE HEAT RECOVERY CORE After removing the carbon and particle filters, slice out the heat recovery core. It may be difficult to slide out the heat recovery core, hold tight and pull.
Page 10
Epurair VRC-95 - Owner’s manual PAGE 10 IMPORTANT Your HRV is equipped with a drain line conection to remove condensation from the heat recovery core. It is important to verify this drain once a year to insure that it is not obstructed in any manner if the drain line is blocked, an overflow in the drain pan will occur.
PAGE 11 SMOKE ALARM (Option) Your Epurair HRV can be equipped with an optional smoke detector. The smoke detector should be installed at the highest point in your house. If the smoke detector comes on, the Epurair system should automatically shut off so that no fresh air comes in to increase fire or smoke and therefore giving you more time to evacuate.
(15, 30, 45 minutes) LIMITED GUARANTEE The motor inside the Epurair unit is guaranteed to the original purchaser for a duration of FIVE (5) years from the date of purchase. The HEPA filter is guaranteed for TWO (2) years and all other components with the exception of the filters that are guaranteed for ONE (1) year.
Need help?
Do you have a question about the VRC-95 and is the answer not in the manual?
Questions and answers