MC Piece Counting Scale – User Manual Contents 1. Precautions………………………………………………………………………3 2. Installation……………………………………………………………………….. 4 3. Name and functions……………………………………………………………. 6 Key board………………………………………………………………………... 6 Display…………………………………………………………………………… 8 4. Operation………………………………………………………………………... 9 Power ON/OFF ……………………………………………………………….9 Zero………………………………………………………………………………. 9 Tare………………………………………………………………………………. 9 5. Parts Counting . ………………………………………………………………..10 Setting unit weight………………………………………………………………10 Entering a known unit weight…………………………………………………..10...
MC Piece Counting Scale – User Manual 1. Precautions Read this manual before operating or servicing this equipment. Follow these instructions carefully. Disconnect this equipment from the power source before cleaning of performing maintenance. Keep the manual for your future reference.
MC Piece Counting Scale – User Manual 2. Installation Unpacking Carefully take the balance out of its package, make it sure it’s not damaged and all accessories are included. Accessories, 1. Balance 2. Adaptor 3. Stainless steel pan 4. Product manual Keep the packaging material for your future use.
Page 7
MC Piece Counting Scale – User Manual Turn on the power switch. On / Off switch is locating below the right side of the scale. Press switch forward to turn on the scale. If you want to turn off, press backward the switch.
MC Piece Counting Scale – User Manual 3. NAMES AND FUNCTIONS Overall View Key Board - 6 -...
Page 9
MC Piece Counting Scale – User Manual Keys Press this key to Enter individual unit weights and the present tare Clear incorrect entries and error conditions Returns the display to zero. Enter the clear tare weights, Storing the current weight as tare value.
MC Piece Counting Scale – User Manual Display Overlay : Battery indicator. When it’s illuminated, battery should be recharge. BATT : Net weight indicator. When the scale has been tared and the display is in NET mode Stable : Stable indicator. When it’s illuminated, the scale is stable. Zero : Zero indicator.
MC Piece Counting Scale – User Manual 4. OPERATION Initial Start-Up Warm-up time of 15 minutes stabilizes the measured values after switching on. 1. Power ON/OFF Power switch is located below the right side of the scale. Switch on the scale by pressing on/off.
MC Piece Counting Scale – User Manual 5. PARTS COUNTING 1. Setting Unit Weight For this function you need to know the average weight of objects to count. This value can be obtained by weighing a known number of pieces so that the balance calculation, the average unit weight or manually entered through the keyword.
MC Piece Counting Scale – User Manual 5. Setting High / Low limits. Pressing Pst the user can select count or weigh and set limits. For example: Press Pst will display "Hi Cnt" pass counting by weighing Press Tare “Hi cnt” “1.999”...
MC Piece Counting Scale – User Manual 6. PARAMETER PARAMETER BLOCK STEP DESCRIPTION DEFAULT FI CAL Calibration F2 dI Set Division d 3000 F3 Cnt A/D Count F4 AU Auto Accumulation AU oFF F5 AZn Auto Zero Range F6 Pin...
Page 15
MC Piece Counting Scale – User Manual SETTING PARAMETERS Switch on the scale. Press during that start up time. Display will show „Pin‟ briefly if PIN is activated. Press the PIN number to get into the parameter menu. The default PIN number is “0000”.
Page 16
MC Piece Counting Scale – User Manual 2. Normal Calibration (Recommended) Enter the parameter menu using by password. (Default password “0000”) When the parameter menu show F1 CAL Set Weight FI CAL UnLoad Load W/t Remove W/t Pass F2 SET DIVISION...
Page 17
MC Piece Counting Scale – User Manual F4 AU ACCUMULATION Set the Accumulation Accumulate Manually F4 AU AU oFF Automatic Accumulation AU on P ASk Manually send data to RS 232 P Cont Press to select. F5 AZn AUTO ZERO RANGE Set the Auto Zero Range.
Page 18
MC Piece Counting Scale – User Manual F6 Pin PASSWORD Set the new password (pin number). F6 Pin Pin 1 Enter the new four digit pin number ---- Pin 2 Press Re-enter the new four digit pin number Press F7 SPd SENSING SPEED...
Page 19
MC Piece Counting Scale – User Manual F8 oFF AUTO POWER Set the Automatic power off F8 oFF No Off oF 0 When display is stable and not in use, Auto off within three minutes oF 3 Auto off within five minutes...
Page 20
MC Piece Counting Scale – User Manual F10 bEP B E E P Set the beep sound When the value is in the limit F10 bEP When the value is lower than the low limit When the value is in the...
MC Piece Counting Scale – User Manual 7. RS232 PROTOCOL The MC Series of scales can be ordered with an option RS-232 output. Specifications: RS-232 output of weighing data ASCII code 4800 Baud 8 data bits No Parity Connector: 9 pin socket...
Page 23
The 6. package shows the accumulated values in the memory and the loaded scale The 7. package shows the accumulated values in the memory and the empty scale. Now the software sends the command MC to clear the memory. The 8. package shows the empty scale with a clear memory.
MC Piece Counting Scale – User Manual 8. ERROR CODES Error Message Description Solution ----- Maximum load exceeded Unload or reduce weight Incorrect date Enter the date by using format Err 1 “yy;mm:dd” Err 2 Incorrect time Enter the time by using format “hh:mm:ss”...
Page 26
MC Piece Counting Scale – User Manual 9. DRAWING - 22 -...
MC Piece Counting Scale – User Manual PARTS LIST Parts Name Material Spec 230mmX300mm 230mmX300mm Battery Cover Rear Overlay Name Plate Battery Lead Acid 6V/4AH Foam Load cell upper bracket Aluminum Load Cell Hexagon Screw 20Mn M4x16 Load cell lower bracket...
MC Piece Counting Scale – User Manual Load cell specifications Model No NA22 C2X1 Rated Capacity 6~40 (kg) 6~50 (kg) Rated Out put 2.0mV/V± 0.2 mV/V 2.0 mV/V± 0.2 mV/V Excitation 15 VDC 20 VDC Voltage IP Level IP65 IP64...
Need help?
Do you have a question about the MC and is the answer not in the manual?
Questions and answers