OuTBACK™ 185 (Au) OuTPuT CONNECTIONS
OUTBACK
TM
185 (AU)
7
8
9
10
1. CuRRENT CONTROL DIAL
2. WELD OuTPuT TERMINALS (2)
3. GROuND STuD
4. CIRCuIT BREAKERS (2) - 15 AMP
5. RECEPTACLE - 240 VOLT, 15 AMP (2)
6. HOuRMETER
ELECTRICAL OuTPuT CONNECTIONS
See Figure A.1 for the location of the current control
dial, weld output terminals, ground stud, circuit break-
ers and RCD, 240 volt receptacles.
WELDING CABLE CONNECTIONS
Cable Size and Length
Be sure to use welding cables that are large enough.
The correct size and length becomes especially impor-
tant when you are welding at a distance from the
welder.
Table A.1 lists recommended cable sizes and lengths
for rated current and duty cycle. Length refers to the
distance from the welder to the work and back to the
welder. Cable diameters are increased for long cable
lengths to reduce voltage drops.
6
1
3
2
FIGuRE A.1
7. ENGINE SWITCH
8. HIGH/AuTO IDLE
9. CHOKE
10. RCD and BOOT
RECOMMENDED WELDING CABLE
15-30 m (50-100 ft.)
30-46 m (100-150 ft.)
46-61 m (150-200 ft.)
61-76 m (200-250 ft.)
A-4
4
5
TABLE A.1
SIZE AND LENGTH
TOTAL COMBINED LENGTH OF
ELECTRODE AND WORK CABLES
Cable
Length
0-15 m (0-50 ft.)
INSTALLATION
125 Amps
30% Duty Cycle
16mm
(6 AWG)
2
25mm
(5 AWG)
2
35mm
(3 AWG)
2
35mm
(2 AWG)
2
50mm
(1 AWG)
2