  • Page 1 ComfortDry CD55 & CD90 READ AND SAVE THESE INSTRUCTIONS Whole-House Central Dehumidifiers T R I O N | w w w . t r i o n i a q . c o m ®...
  • Page 2: Table Of Contents

    I n s t a l l a t i o n , O p e r a t i o n , a n d M a i n t e n a n c e M a n u a l READ AND SAVE THESE INSTRUCTIONS TABLE OF CONTENTS Introduction ............................
  • Page 3: Introduction

    • Installation/operation manual If any items are not found, please contact TRION The benefits of a properly humidified environment Customer Service at 800-884-0002. are many. They include personal comfort as well as the preservation of furniture, draperies, carpets,...
  • Page 4: Specifications

    O p era t i n g M o d e s/ C o nf i g u r a t i o n s There whole-house dehumidification configurations that can be addressed with the CD55 The ComfortDry CD55 and CD90 support whole- and CD90. In the first of these configurations (see house dehumidification standalone...
  • Page 5: Unit Location

    I n s t a l l a t i o n , O p e r a t i o n , & M a i n t e n a n c e M a n u a l crawlspaces, or perhaps in a closet with ducting to 4.
  • Page 6 ACCA manual “D” of ASHRAE’s Fundamentals of Air System Design. For supply side air ducting (output from the dehumidifier), both the ComfortDry CD55 and CD90 Figure 3. Drain Tube Drawing have 6” round ducts.
  • Page 7 I n s t a l l a t i o n , O p e r a t i o n , & M a i n t e n a n c e M a n u a l on all dehumidifier duct connections to reduce Return Ducting for Whole-House Separate Room noise and vibration transmitted to rigid ductwork...
  • Page 8: Wiring

    I n s t a l l a t i o n , O p e r a t i o n , a n d M a i n t e n a n c e M a n u a l Terminals A3 and A4 need to be powered to switch W i ri n g the dehumidifier on, typically connecting A4 to the...
  • Page 9: Unit Controls

    Whole-House Mode and you want to turn the main power off, then switch the dehumidifier into Unit/ TRION dehumidifiers are equipped with the basic Standalone Mode that re-arms the OFF switch (both required interconnection as illustrated in Figure mode indicator lamps off).
  • Page 10: Configuration & Operation

    I n s t a l l a t i o n , O p e r a t i o n , a n d M a i n t e n a n c e M a n u a l 3.
  • Page 11: Maintenance

    M a i n t e n a n ce by a red Compressor light. Likewise, if powering OFF, there may be a short one minute delay required for the ComfortDry CD55 unit to cycle down and shut off. Cleaning the Machine Body Use a damp cloth to clean exterior of unit.
  • Page 12: Warranty

    Product by an original customer purchasing from a Cleaning the Filter (See Figure 9) TRION or an authorized TRION reseller; and the 1. Unplug the unit. Product’s condenser, evaporator, and compressor 2.
  • Page 13 CUSTOMER TRION such that TRION receives such claim prior CONSENTS TO THE JURISDICTION OF THE to the end of the applicable warranty period. TRION FEDERAL AND STATE COURTS LOCATED shall have no obligation hereunder with respect to THEREIN, SUBMITS TO THE JURISDICTION...
  • Page 14 TRION ® 101 McNeill Rd. | Sanford, NC 27330 P: 800.884.0002 | F: 800.458.2379 | www.trioniaq.com | customerservice@trioniaq.com Form No. 268513-001 Rev. 10/16 © TRION 2016. All Rights Reserved.