Now start...
WARNING
Excessive Weight Hazard
Use two or more people to move and
install range.
Failure to do so can result in back or
other injury.
1.
Remove shipping materials, tape
and protective film from range. Keep
cardboard bottom and shipping base
under range. Remove oven racks and
parts package from inside oven.
2.
Take four cardboard corners from the
carton. Stack one cardboard corner on
top of another. Repeat with other two
corners. Place them lengthwise on the
floor behind the range — to support the
range when it is laid on its back.
3.
Firmly grasp the range and gently
lay it on its back on the cardboard
corners.
4.
Pull cardboard shipping base
firmly to remove.
5.
Use an adjustable wrench to
loosen the leveling legs four complete
turns.
6.
Place
cardboard or
hardboard in front
of range. Stand range back up onto
cardboard or hardboard.
WARNING
Tip Over Hazard
A child or adult can tip the range and
be killed.
Connect anti-tip bracket to rear
range foot.
Reconnect the anti-tip bracket, if the
range is moved.
Failure to follow these instructions can
result in death or serious burns to
children and adults.
Contact a qualified floor covering installer
for the best procedure for drilling
mounting holes through your type floor
covering.
7.
Use the anti-tip
bracket template to
install the anti-tip
bracket.
Anti-tip bracket must be
anchored securely to
the sub-floor.
Depending on
the thickness of
your flooring,
longer screws
may be
necessary to anchor
the bracket to the sub-floor.
Longer screws are available from your
local hardware store.
Check that range is on cardboard
shipping base to protect floor covering.

Electrical connection

8.
Remove the terminal block cover
located on the back of range.
terminal
block cover
9.
Depending on your electrical
supply, make the four-wire or three-wire
connection to the range following the
"Power supply cord method" or "Direct
wire method" instructions for copper
wire or aluminum wire depending on the
connection needed.
knockout
opening for
40 amp
power
supply cord
knockout
opening
for power
supply
cable