ETIC IPL-C User Manual

Cellular router firewall
Hide thumbs Also See for IPL-C:

Advertisement

Quick Links

IPL-C
Cellular Router Firewall
_________________
USER GUIDE
Cellular Router Firewall
DOC_DEV_IPL-C_User guide_A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IPL-C and is the answer not in the manual?

Questions and answers

Summary of Contents for ETIC IPL-C

  • Page 1 IPL-C Cellular Router Firewall _________________ USER GUIDE Cellular Router Firewall DOC_DEV_IPL-C_User guide_A...
  • Page 3 The IPL-C cellular router is designed and manufactured by ETIC TELECOM 13 Chemin du vieux chêne 38240 MEYLAN FRANCE TEL : + (33) (0)4-76-04-20-05 FAX : + (33) (0)4-76-04-20-01 E-mail : hotline@etictelecom.com web : www.etictelecom.com...
  • Page 5: Table Of Contents

    Push-buttons .................... 15 Connectors ....................16 IPL-C-400 or IPL-CW-400 router (WiFi option)........... 19 IPL-C-220 ou IPL-CW-220 router (WiFi option) ........... 20 IPL-C-230 or IPL-CW-230 router (WiFi option) ........... 21 IPL-C-260 ou IPL-CW-260 router (WiFi option) .......... 22 IPL-C-261 or IPL-CW-261 router (WiFi option) ........... 23 DIN rail mounting ....................
  • Page 6 CONTENT … INSTALLATION Connecting the router to the cellular network ............29 10.1 Controls before installing the router ............29 10.2 Cellular antenna ..................29 10.3 Coaxial cable ..................... 29 10.4 Cellular service subscription ..............30 10.5 Installing the SIM card ................30 10.6 Controlling the conformance of the connection ..........
  • Page 7: Overview

    OVERVIEW 1 Certificate of conformity The manufacturer, ETIC Telecom – 13 chemin du vieux chêne – 38240 Meylan – France, Hereby declares that the listed product Type of device : Cellular router IPL-C conforms to the Council Directive 1999/5/EC related to radio and telecommunication terminal equipments.
  • Page 8: Products Identification

    OVERVIEW 2 Products identification Cellular router without WiFi interface 261-XY 400-XY 220-XY 230-XY 260-XY IPL-C- Cellular router 4G-3G-GPRS-EDGE • • • • • 3G, GPRS-EDGE : XY = HG 4G, 3G, GPRS-EDGE : XY =LE • • • • •...
  • Page 9 OVERVIEW Cellular router with WiFi interface 261-XY IPL-C- 400-XY 220-XY 230-XY 260-XY Cellular router 4G-3G-GPRS-EDGE • • • • • 3G, GPRS-EDGE : XY = HG 4G, 3G, GPRS-EDGE : XY =LE • • • • • WiFi client or access point 2.4 or 5 GHz •...
  • Page 10: Data-Sheet

    RF field : EN61000-4-3 : 10V/m < 2 GHz Fast transient : EN61000-4-4 Surge voltage : EN61000-4-5 : 4KV line / earth RoHS 2002/95/CE (RoHS) IPL-C-400, IPL-CW-400 10 to 60 VDC IPL-C-230, IPL-CW-230 10 to 60 VDC IPL-C-260, IPL-CW-260 10 to 60 VDC...
  • Page 11 OVERVIEW Client or server IPSEC or OpenVPN Encryption AES256 3DES Certificate X509 or preshared key 16 VPNs maximum of the same type (OpenVPN or IPSec) Stateful packet inspection (50 rules) Deny of service filter Firewall Source & destination IP address & port number filter Remote users filter Logs Date and time stamped logs...
  • Page 12: Product Overview

    WiFi ( client or access point) and a serial gateway  4.1 Applications That features in the same product make the IPL-C a top level solution for remote SCADA systems and remote maintenance through the Internet. Page 12 Cellular Router Firewall...
  • Page 13: Product Functionnalities

    Raw TCP client or server Raw UDP Telnet Modbus master or slave Unitelway Emails – SMS The IPL-C is able to send an email or a SMS when the digital input turns ON or OFF Page 13 Cellular Router Firewall DOC_DEV_IPL-C_User guide_A...
  • Page 14: Router Organisation

    OVERVIEW 4.3 Router organisation The IPL-C router provides two IP interfaces : The ADSL interface (WAN interface) to reach the Internet or a private service and the LAN interface to connect the machine. WAN interface : The IPL-C router provides three WAN interfaces : the ADSL interface is the main WAN interface;...
  • Page 15: Installation

    INSTALLATION 1 Product description 1.1 Dimensions 1.2 Push-buttons Rear panel push-button Pressing the rear Function panel PB During operation Flashing red The default IP address 192.168.0.128 is selected The current configuration remains active During power-up Flashing red The factory configuration and the default IP address 192.168.0.128 are selected.
  • Page 16: Connectors

    INSTALLATION 1.3 Connectors Supply voltage connector Position Signal Function Power 1 + Supply voltage Power 1 - Digital inputs & outputs Position Signal Function Entrée TOR 0V Entrée TOR+ Dgital output + Digital output - RJ45 Ethernet) Position Name Description Tx + Emission polarity + Tx -...
  • Page 17 INSTALLATION RJ45 RS232 DCE interface Pos. Signal Function RJ45 DTR - 108 Data terminal ready TD - 103 Data Emission RD - 104 Data Reception DSR - 107 Data set ready SG - 102 Ground Inutilisé CTS - 106 Clear to send Request to send RTS - 105 Out = Signal provided by the router.
  • Page 18 INSTALLATION 5 positions RS422 screw block IPL-C-260 IPL-CW-260 Position Signal Function Sortie RS422 transmission polarity + Sortie RS422 transmission polarity - Common voltage Entrée RS422 Reception polarity + RS422 Reception polarity - RS422 DIP switches IPL-C-260 IPL-CW-260 SW 1 SW 2 The two 470 Ohm polarisation R.
  • Page 19: Ipl-C-400 Or Ipl-Cw-400 Router (Wifi Option)

    INSTALLATION 1.4 IPL-C-400 or IPL-CW-400 router (WiFi option) IPL-C-400 IPL-CW-400 LED INDICATORS IPL-C-400-XY & IPL-CW-400-XY Designation Function Operation Green The unit is ready Power-up The SIM card is not present Hardware failure or firmware update process Cellular SIM card not present – cellular interface disabled...
  • Page 20: Ipl-C-220 Ou Ipl-Cw-220 Router (Wifi Option)

    INSTALLATION 1.5 IPL-C-220 ou IPL-CW-220 router (WiFi option) IPL-C-220 IPL-CW-220 LED INDICATORS IPL-C-220-XY & IPL-CW-220-XY Designation Function Operation Green The unit is ready Power-up The SIM card is not present Hardware failure or firmware update process Cellular SIM card not present – cellular interface disabled...
  • Page 21: Ipl-C-230 Or Ipl-Cw-230 Router (Wifi Option)

    INSTALLATION 1.6 IPL-C-230 or IPL-CW-230 router (WiFi option) IPL-C-230 IPL-CW-230 LED INDICATORS IPL-C-230-XY & IPL-CW-230-XY Designation Function Operation Green The unit is ready Power-up The SIM card is not present Hardware failure or firmware update process Cellular SIM card not present – cellular interface disabled...
  • Page 22: Ipl-C-260 Ou Ipl-Cw-260 Router (Wifi Option)

    INSTALLATION 1.7 IPL-C-260 ou IPL-CW-260 router (WiFi option) IPL-C-260 IPL-CW-260 LED INDICATORS IPL-C-260-XY & IPL-CW-260-XY Designation Function Operation Green The unit is ready Power-up The SIM card is not present Hardware failure or firmware update process Cellular SIM card not present – cellular interface disabled...
  • Page 23: Ipl-C-261 Or Ipl-Cw-261 Router (Wifi Option)

    INSTALLATION 1.8 IPL-C-261 or IPL-CW-261 router (WiFi option) IPL-C-261 IPL-CW-261 LED INDICATORS IPL-C-261-XY & IPL-CW-261-XY Designation Function Operation Green The unit is ready Power-up The SIM card is not present Hardware failure or firmware update process Cellular SIM card not present – cellular interface disabled...
  • Page 24: Din Rail Mounting

    INSTALLATION 2 DIN rail mounting Mounting the unit on the 35 mm horizontal DIN rail Removing the unit from the DIN rail 3 Cooling To avoid obstructing the airflow around the unit, the spacing must be at least 25 mm above and below, and 10 mm left and right.
  • Page 25: Supply Voltage

    INSTALLATION 4 Supply voltage IPL-C-400, IPL-CW-400 Minimum input voltage : 10 V DC IPL-C-230, IPL-CW-230 Maximum input voltage : 60 VDC IPL-C-260, IPL-CW-260 IPL-C-261, IPL-CW-261 IPL-C-220, IPL-CW-220 Minimum input voltage : 10 V DC Maximum input voltage : 30 VDC The consumption is lwer than 6 W.
  • Page 26: Rs485 Connection (Ipl-C-220 Or Ipl-Cw-220)

    INSTALLATION 7 RS485 connection (IPL-C-220 or IPL-CW-220) The RS485 serial interface is provided on the front panel 2 positions screw-block. It is not isolated. Long RS485 line or high data rate if the RS485 line is longer than10 meters or if the...
  • Page 27: Rs422 Isolated Interface (Ipl-C-260 Or Ipl-Cw-260)

    INSTALLATION 8 RS422 isolated interface (IPL-C-260 or IPL-CW-260) The RS422 interface is isolated. When two devices or more are connected to the RS422 interface of the IPL router, the IPL router must be the only device to transmit data ont the TX+/TX- line towards all the other devices.
  • Page 28: Rs485 Isolated Interface (Ipl-C-261 Or Ipl-Cw-261)

    INSTALLATION 9 RS485 isolated interface (IPL-C-261 or IPL-CW-261) The RS485 interface is isolated (3 wires : A- / B+ plus the common voltage wire). The polarisation and termination resistors can be selected with DIP switches. The polarisation résistors must be enabled by one device of the bus.
  • Page 29: Installation

    10.3 Coaxial cable If necessary, the antenna can be connected to the IPL-C router through a coaxial cable. The signal attenuation in a usual coaxial cable is 0.2 to 0.4 dB / m diameter , mm), that is to say 2 to 4 dB for a 10 meter long cable.
  • Page 30: Cellular Service Subscription

    INSTALLATION 10.4 Cellular service subscription The router RAS is designed to connect to the LTE-UMTS-GPRS data transmission service like the one used by the tablets. The subscription should also provide the SMS service if SMS alarms are required. A telephone service subscription is not needed. One will take care to subscribe to a service authorizing the right volume of data per month (MB/month) and to check the price of the MB exceeding the limit of the subscription plan, if it exists.
  • Page 31: Controlling The Conformance Of The Connection

    INSTALLATION 10.6 Controlling the conformance of the connection After installing and setting up the router, control the conformance of the connection : Reception level The reception level must be better than -90 dBm (two flashes of the reception level led indicator). See the table below.
  • Page 33: Preparing The Setup

    PREPARING THE SETUP 1 First setup from factory, the IP address of the router is 192.168.0.128. Step 1 : Create or modify the PC IP connection. Assign to the PC an IP @ in accordance with the router RAS IP address. For the first configuration, assign for instance 192.168.0.127 to the PC.
  • Page 34: Https Set-Up Modifications Through The Wan Interface

    PREPARING THE SETUP 3 HTTPS set-up modifications through the WAN interface The administration web server is located at the LAN IP address. Coming from factory, access to the administration web server is not allowed through the WAN interface To use HTTPS instead of HTTP to setup the product or to authorise access to the administration web server through the WAN interface, ...
  • Page 35: Saving Or Restoring A Set Of Parameters

    In a second step, any set stored inside the router and displayed with the Configurations table can be saved as an editable file stored outside the ETIC router. Inversely, a saved file can be loaded to the product Configurations table and then, if necessary, declared as the active set of parameters.
  • Page 36: Configuration Steps

    PREPARING THE SETUP 7 Configuration steps To configure the router, we advise to proceed as follows :  Cellular interface setup  LAN interface setup  VPNs setup  Routing and IP address translation functions setup  Remote users connections, the user list and the access rights setup ...
  • Page 37: Maintenance

    MAINTENANCE 1 Diagnostic 1.1 Logs  Select the Diagnostic > Logs menu Main logs It registers the ADSL connections & disconnections the VPN connections & disconnections theremote users connections & disconnections The router starts OpenVPN & IPSec Logs These logs registers the detail of the VPN connections Advanced logs That logs registers details about the following events : ADSL events...
  • Page 38: Network Status

    MAINTENANCE 1.2 Network status To display the Interfaces status pages ,  Select The Diagnostic > Network status>Interfaces menu. The Interfaces page summarizes the current information of each interface of the router, like for instance : LAN interface : MAC and IP address Ethernet ports status …...
  • Page 39: Serial Gateways Status

    The Wifi scanner displays the main information about each WiFi network : MAC address of the access point, SSID, reception level. Remark : The WiFi interface of the ETIC router needs to be registered as a WiFi client interface. Page 39...
  • Page 40: Firmware Update

    2 Firmware update The firmware update can be carried-out locally or remotely. If the firmware update operation do not succeed, for instance if the connection fails, the ETIC router restarts with the current firmware. Once the firmware update has been carried-out, the ETIC router restores the previous current set of parameters.
  • Page 42 ETIC TELECOM 13 chemin du vieux Chêne 38240 Meylan France contact@etictelecom.com...

Table of Contents