Download Print this page

Technical Specifications - FastIron 400 Manual

Enterprise layer 2 / 3 switches

Advertisement

Technical Specifications

IEEE Compliance
- 802.3,10BaseT
- 802.3u 100BaseTX,100BaseFX
- 802.3z 1000BaseSX
- 802.3z 1000BaseLX
- 802.3ab 1000BaseT
- 802.3ae 10 Gigabit Ethernet
- 802.3x Flow Control
- 802.3ad Link Aggregation
- 802.3af Power over Ethernet
- 802.1d Bridging
- 802.1p/q VLAN Tagging
- 802.1w Rapid STP
- 802.1x user authentication
- 802.3 Ethernet Like MIB
- Repeater MIB
- Ethernet Interface MIB
- SNMP V1,V2c and V3
- SNMP MIB II
RFC Compliance
BGPv4
- RFC 1269,1657 BGP3 and BGP4 MIBs
- RFC 1745 OSPF interactions
- RFC 1771 BGPv4
- RFC 1965 BGP4 confederations
- RFC 1997 Communities & Attributes
- RFC 2385 MD5 Authentication of BGP Session
- RFC 2439 route flap dampening
- RFC 2796 route reflection
- RFC 2842 BGP4 capabilities
OSPF
- RFC 1583 and 2328 OSPF v2
- RFC 1587 OSPF NSSA
- RFC 1745 OSPF Interactions
- RFC 1765 OSPF Database Overflow
- RFC 1850 OSPF Traps
- RFC 1850 OSPF v2 MIB
- RFC 1997 Communities Attributes
- RFC 2154 OSPF w/Digital Signatures
(Password,MD-5)
- RFC 2178 OSPF
- RFC 2328 OSPF v2
- RFC 2370 OSPF Opaque LSA Option
- RFC 2385 TCP MD5
- RFC 2439 Route Flap Damping
- RFC 2842 Capabilities Advertisement
- RFC 2918 Route Refresh Capability
IS-IS
- RFC 1195 Routing in TCP/IP and
Dual Environments
- RFC 1377 PPP
- RFC 2763 Dynamic Host Name Exchange
- RFC 2966 Domain-wide Prefix Distribution
RIP
- RFC 1058 RIP v1
- RFC 1723 RIP v2
- RFC 1812 RIP Requirements
IP Multicast
- DVMRP v3-07
- PIM-DM v1
- RFC 1112 IGMP
- RFC 1122 DVMRP Host Requirements
- RFC 1122 Host Extensions
- RFC 1256 ICMP Router Discovery Protocol
- RFC 2236 IGMP v2
- RFC 2283 MBGP
- RFC 2362 PIM-SM
- RFC 3618 MSDP
General Routing Protocols
- RFC 768 UDP
- RFC 783 TFTP
- RFC 791 IP
- RFC 792 ICMP
- RFC 793 TCP
- RFC 826 ARP
- RFC 854 TELNET
- RFC 894 IP over Ethernet
- RFC 903 RARP
- RFC 906 TFTP Bootstrap
- RFC 951 BootP
- RFC 1027 Proxy ARP
- RFC 1122 Host Requirements
- RFC 1256 IRDP
- RFC 1519 CIDR
- RFC 1541,1542 & 2131 BootP/DHCP Helper
- RFC 1542 BootP Extensions
- RFC 1591 DNS (client)
- RFC 1812 General Routing
- RFC 2338 VRRP
Others
- RFC 1157 SNMPv1
- RFC 1191 Path MTU discovery
- RFC 1215 SNMP generic traps
- RFC 1354 IP Forwarding MIB
- RFC 1573 SNMP MIB II
- RFC 1757 RMON Groups 1,2,3,9
- RFC 1905,1906 SNMPv2c
- RFC 2030 SNTP
- RFC 2068 HTTP
- RFC 2138 RADIUS
- RFC 3176 sFlow
- RFC 3411 SNMPv3 framework
- RFC 3412 SNMPv3 processing
- RFC 3414 SNMPv3 USM
- RFC 3415 SNMPv3 VACM
- TACACS+ v1.78
Network Management
- IronView Network Manager (INM) Web based graphical
user interface
- Integrated Standard based Command Line Interface (CLI)
- sFlow (RFC 3176)
- Telnet and SSHv1
- SNMP
- HTTP and HTTPS
- RMON HP OpenView for Sun Solaris,HP-UX,IBM's
AIX,and Windows NT
Element Security Options
- AAA
- RADIUS
- Secure Shell (SSH v2.0)
- Secure Copy (SCP)
- TACACS/TACACS+
- Username/Password (Challenge and Response)
- FI-level Access Mode (Standard and EXEC Level)
- Protection for Denial of Service attacks,such as TCP SYN
or Smurf Attacks
Environmental
- Operating Temperature:0 °C to 40 °C (32 °F to 104 °F)
- Relative Humidity:5 to 90%,@ 40 °C (104 °F),
non-condensing
- Operating Altitude:10,000 ft (3,000 m) maximum
- Storage Temperature:-25 ºC to 70 ºC (-9 ºF to 158 °F)
- Storage Altitude:15,000 ft (4,500 m) maximum
- Storage Humidity:95% maximum relative humidity,
non-condensing
Safety Agency Approvals
- CAN/CSA C22.2 No.60950-1-03/UL60950-1
First Edition,Safety of Information Technology Equipment
- EN 60825-1 Safety of Laser Products—Part 1:
Equipment of Classification,Requirments and User's Guide
- EN 60825-2 Safety of Laser Products—Part 2:
Safety of Optical Fibre Communication Systems
- EN 60950-1/IEC 60950-1
Safety of InformationTechnology Equipment
Emissions
- Canada Interference Causing Equipment Regulations
- FCC Class A
- EN 55022/CISPR-22 Class A/VCCI Class A
Immunity
- EN 61000-3-2 Power Line Harmonics
- EN 61000-4-2 ESD
- EN 61000-4-3 Radiated Immunity
- EN 61000-4-4 EFT
- EN 61000-4-5 Surge
- EN 61000-4-6 Low Frequency Common Immunity
- EN 61000-4-11 Voltage Dips and Sags
- Generic:EN 50082-1
- ESD:IEC 61000-4-2;4 kV CD,8 kV AD
- Radiated:IEC61000-4-3;3 V/m
- EFT/Burst:IEC 61000-4-4;1.0 kV (power line),
0.5 kV (signal Line)
- Conducted:IEC 61000-4-6;3 V
Warranty
- 1-year hardware
- 90-day software
Mounting Options
- 19" Universal EIA (Telco) Rack or Tabletop
6

Advertisement

loading

This manual is also suitable for:

8001500