Readjusting The Knife Cut-Through Position; Non-Repeat Device - Perfecta 76 UC Service Instructions Manual

Table of Contents

Advertisement

Readjusting the
Knife Cut-Through
Position
The cut-through position is de-
scribed under "Adjusting the Cut-
Through Position" in the Operating
Instructions manual.
Machine Size 76/92 (Fig.19)
For a.m. cutting sizes the Knife Cut-
through position is readjusted at the
right hand side of the machine as
following:
Right side:
Remove cap from opening 3.
Loosen screw 5 by two turns.
Insert knife changing tool 1 into
centre of bolt 6.
Anticlockwise turning: Lift knife.
Clockwise turning: Drop knife.
Tighten screw 5. The position
of screw 5 indicates the position
of the knife. Screw up means knife up.
Remove the tool after setting!

Non-Repeat Device

The upper dead centre of the knife
beam is stopped and controlled
by control switches S52 and S54
and is monitored by the safety
processor control system which
immediately stops the knife travel
in case of any irregularities. Refer
to "Setting the Automatic Stop-
ping Device".
In addition, all PERFECTA
guillotines are provided with a
mechanical non-repeat device
(catch/locking pin), a third safety
means for the upper dead center,
which locks the knife beam to the
machine frame.
1/01 E Service Instructions
5
3
6
Fig. 19
If this non-repeat device responds
due to excessive overrun, the
knife beam must be manually
returned to its upper dead centre.
Refer to "Manual Cranking".
In case the overload protection
device responds, refer to "Knife
Drive Assembly Overload Pro-
tection Device".