Summary of Contents for Gorenje Aqua ECOLOGIC
Page 1
__________ PELET STOVE FOR CENTRAL HEATING Aqua ECOLOGIC Instructions for use, maintenance and installation September 2015...
Page 2
In doing so, always specify the number of the chapter where there is some ambiguity. Printing, translation and reproduction, even in part, of this manual is subject to licensing by Gorenje, d.d., which means that Gorenje d.d. must approve these actions. Technical information, figures, and specifications in this manual must not be given to a third party.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 of gases that are not completely burned. This significantly increases the thermal efficiency and reduces harmful emissions of carbon monoxide (CO), because the incomplete combustion is minimized. TABLE OF CONTENTS 1.
Page 4
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 14. PRACTICAL INSTRUCTIONS AND TIPS FOR THE USE OF THE HEATING SYSTEM ....28 15. FILLING WITH WOODEN GRANULES ....................28 16. DESCRIPTION AND MODE OF OPERATION OF THE CONTROL SYSTEM ........29 16.1.
This manual reflects a work of art at the moment when the stove was placed on the market. Therefore, GORENJE does not take into account the stoves that are already on the market with the appropriate technical documentation and considers them as defective or inadequate after any kind of modification, adaptation or application of new technologies to newly produced machines.
If you have lost your manual, the manufacturer can provide you with a new one. 3. RESPONSIBILITIES OF THE MANUFACTURER In issuing these instructions, GORENJE accepts no civil or legal liability, direct or indirect, due to: Accidents caused by not respecting the standards and specifications given in this manual, ...
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 the type of stove to be connected, whether the room corresponds to the stove where the stove will be installed, which is expressed as the minimum size required for installation, set forth by the manufacturer of the stove, ...
Page 8
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 The stove is on the plastic pins that have M10 bolts (4 items), that are threaded into the stove base. At the screws there are M10mm threaded nuts to the plastic parts. The legs are wound up all the way to the base of the stove.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 DANGER ! It is forbidden to install shut-off valves for the flow (draft) of air (flap valves that can prevent airflow or disable drafts). ATTENTION If the ejection path of smoke creates such a bad draft, of a bad flow of air (many curves, improper completion of the ejection of smoke, constriction, etc.) discharge of smoke can be bad, or in a situation like this smoke...
Page 10
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 B) Maximum cross section is 15 x 15 cm or a 15-cm diameter, with the maximum height of 4-5 m. C) Gasket D) Inspection hole - for control Flue pipes that are in poor shape, or are made out of inappropriate materials (asbestos cement, galvanized sheet, etc.
Page 11
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 Figure 1 Figure 2 When using the connecting pipe between the stove and the flue drain pin, be sure to use a "T" connector (as shown in Figures 5 and 6), with the clean-out cover (cap) next to the stove. Applying the "T" connector must enable the collection of ash, which is produced inside the tube, and the smoke drain pipe must occasionally be cleaned without having to remove the tube.
Page 12
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 Figure 2a: Cleaning elements Ideal vacuum primarily depends on the absence of barriers such as narrowing and/or corner connectors. It is recommended that the knees are 30°, 45 °, and 90 °. Knee at 90 ° shall be three-fold (Figure 2b).
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 4.3 INSULATION AND THE DIAMETER OF THE OPENING (HOLE) ON THE ROOF (OR IN THE WALL) Once you determine the position of the stove, it is necessary to make a hole through which a smoke pipe must pass.
Page 14
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 Ø100 Ø80 Figure 6 1. A hose fitting with a T shape - a T connector pipeline 2. Cleaning direction 3. Opening, a window for servicing/inspection 4. Cleaning direction 5.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 The walls are made of wood, or in any case, flammable, or parts that are flammable. Concrete wall or a roof A wall or a brick roof Table 2: Insulation thickness for the part of the system that passes through the wall or roof Above all it is necessary to provide the PERFECT AIRFLOW (draft) in pipes for smoke exhaustion that has to be free, without any obstacles, such as different narrowing or corners.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 The opening of the outer supply of combustion air must not be connected by pipes. If the room has some other devices for heating, the supply of combustion air must ensure the amount of air that is required for proper operation of the device.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 - If the stove is not used for a long time, unplug it or switch to the switch off (0) position. In the event of failure or malfunction, turn off the stove right away or switch to a switch off (0) position and contact an authorized service center.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 - Always use safety equipment and personal protective equipment, - Turn off the power supply before they start working, - Always use the appropriate tools, - Before they begin any work on the stove they need to keep in mind that it should be cold and that the ashes should be cold as well.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 - Only use the fuel that meets the manufacturer's instructions, - Always follow the maintenance plan for the stove, - Clean the stove every day (only when the stove and the ash are cold),...
Page 20
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 - Turn off the stove from the power supply before you start doing anything, - Before you start doing anything make sure the stove and the ash are cool,...
Page 21
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 The ash container should be vacuumed or emptied if it is full. Make sure the stove and the ash are cool. Upper ash container must be cleaned every or every other day, by vacuuming or by simply throwing the ashes away.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 Clean the glass with a soft cloth. Glass is made from pyrocheramics resistant to high temperatures. In case of damage, before re-using the stove, replace the glass. The glass must be replaced only by the authorized persons.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 Places that need to be cleaned at least twice a year. Figure 15: Places that need to be cleaned at least twice a year 7.3. SPECIAL MAINTENANCE Your stove is a heat generator that uses pellets as solid biofuel. This is why you should do special maintenance once a year.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 DANGER ! Do not use the stove to burn waste. 9. THE PELLET QUALITY IS VERY IMPORTANT This stove uses pressed wood (pellet) as fuel. As there are many products like this on the market it is important that you select pellets as fuel that is not dirty.
15. Boiler GORENJE disclaims all liability in case of a material or bodily harm, in the event of failure, poor functioning, if the above recommendations are not followed.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 Figure 16 11. PRESSURE AND RETURN PIPE Outputs of the pressure and return pipes on the boiler are 1'' and you cannot reduce them or taper to the first bifurcation.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 12.1. SAFETY VALVE It is set up under the lid of the stove on the pressure line. Input connection is R1/2". It opens with water pressure of 2.5 bar. You can get to it by removing the right lateral side, when you are looking at the stove.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 13. INSTALLING AND IGNITING Before the combustion starts entire system of central heating should be water-filled, well-vented, and the stove properly connected to the chimney, as discussed in previous counts.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 16. DESCRIPTION AND MODE OF OPERATION OF THE CONTROL SYSTEM 16.1. DESCRIPTION OF THE PUSH BUTTON DISPLAY Display Display Button to adjust - MENU button ON/OFF push button...
Page 30
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 dosing indicator The display when the stove is running in the combustion stage Upper pointer: The upper display alternately shows: BURN, and then P5D5 , with actual current running force, and adjusted running force.
Page 31
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 Push button - Pressing while the stove is running decreases the set power. With the last pressing of the MENU button, this push-button decreases the desired room temperature.
Page 32
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 Figure 12...
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 16.2. WHEN THE BOILER IS ON The display shows the current phase of the mode of operation (for example TestFire, HeatUp, etc.) and alternately on the upper display shows every 5 seconds the set and the actual capacity of the boiler.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 16.4. SETTING UP THE TIME-CONTROLLED PROGRAM Long pressing (until TIMER is shown) on the MENU button opens a menu time-controlled program. Select ON or OFF to include or exclude the time-controlled program. It is necessary to set up the exact time and day of the week (1 is Monday ...
Page 35
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 Figure 14: Showing the navigation through the menu timer...
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 16.5. SIGNS AND MESSAGES ON THE DISPLAY Signs on the pointers The meaning of the message and the status of the stove The stove is idle. 1 2 :5 3 The stove is idle, but the time mode is activated, so that it turns on °...
Page 37
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 The stove is in the process of stopping and cooling. FIRE STOP When even with the minimal force the room temperature reaches a certain COOL ;level, the level the stove goes into the COOL AIR phase and begins to cool down. The...
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 16.7. MENUS If you press and hold the MENU button the menus will show one after the other. To select the menu you need to let go of the button when you see the respective menu. The descriptions of the menus are listed...
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 service 17. SAFETY MEASURES The stove is equipped with the following safety devices: - PRESSURE REGULATOR Checks the pressure in the chimney. It stops the spiral conveyor of the pellets when the drain is clogged or when there is pressure (wind).
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 - ELECTRIC SAFETY The stove is protected from high current disturbances using standard fuses that are located in the main switch on the back side of the stove and on the control panel - the motherboard.
Page 49
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 4. The doors are not closed 5. Change the type of the wooden granules properly or the glass sealing is and pick the type that is approved by the worn out.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 capacity 2. The thermostat for outside air 4. Check the control panel and change if time. always checks the cool air. needed. 3. The probe that checks the temperature is defective.
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015 When the stove is dismantled, this manual and all other documents related to the stove must be destroyed. 20. THE DURATION OF GUARANTEED SERVICE By this we mean the time in which we guarantee service, accessories, and spare parts, starting from the date of purchase of the appliances.
Page 52
AQUA ECOLOGIC | instructions for use, maintenance and installation | September 2015...
Page 53
__________ PELLET BOILER ECOLOGIC 30 Instructions for use, maintenance and installation June 2015...
Page 54
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 We thank you for your purchase of Gorenje pellet boiler. We ask to thoroughly read instructions for use before installing and using your pellet boiler ECOLOGIC 30. Heating appliances (in the following: "pellet boiler"...
Page 55
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 INDEX PURPOSE OF INSTRUCTIONS FOR USE ..............5 1.1. UPDATES ..........................5 RESPONSIBILITY OF MANUFACTURER ..............5 2.1. BASIC PREVENTIVELY REQUIRED STANDARDS ................. 5 2.2. TRANSPORTATION AND HANDLING OF PELLET BOILER ............6 2.3.
Page 56
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 9.4. TIME PROGRAMME SETTING ....................27 9.5. INDICATIONS AND MESSAGES ON DISPLAY ................28 MENU ........................30 ALARM STATUSES ....................32 INFORMATION REGARDING DESTRUCTION AND DISPOSAL OF BOILER ....39 WARRANTY CONDITIONS ..................
Page 57
If the instructions get lost, request for a new copy of instructions from the manufacturer, authorized reseller or repairman. RESPONSIBILITY OF MANUFACTURER In providing these instructions, Gorenje d.d. rejects any civil or penal liability, direct or indirect, due accidents caused by non-compliance with standards and specifications from these instructions;...
Page 58
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 SIST EN ISO 12100-1: 2004 and A1: 2010; SIST EN ISO 12100-2: 2004 and A1: 2010; SIST EN 303-5: 2012; 61000-6-3: 2007; 61000-6-2: 2005; ...
Page 59
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 possibility of outside air intake; possibility of simultaneous use of generator for connection with other equipment. If the results of all above provided checks are positive, installation may proceed. Carefully heed to instructions provided by the manufacturer, as well as safety and fire prevention standards in force.
Page 60
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 Flue pipe EXAMPLE 1 Flue pipe EXAMPLE 2 Flue pipe EXAMPLE 3 Figure 1: Minimum distance of boiler from boiler room walls...
Page 61
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 If the pellet boiler is installed in a boiler room, where there are other devices, which drain air (other boiler, various suction fans etc.), make sure that the volume of air intake is sufficient for safe operation of combustion device.
Page 62
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 Layout and structure of the space, where the flue is installed, needs to be analyzed. If it passes through walls and/or roof, it must be properly installed in accordance with fire prevention safety standards.
Page 63
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 ATTENTION Extraction of smoke gases must be earthed in accordance with regulations in force. (Earthing connection is required by law). Earthing must be independent of combustion unit. Regarding dimensions and material, from which it is made, the flue pipe must conform to standards UNI 9615-9731, UNI 10683 - EN1856-1.
Page 64
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 Connection between pipes must be always made with male fitting turned upwards (figure 4). It is advisable to avoid using horizontal connections of pipes to flue. If this is not possible, the pipes must not be installed in a downwards angle, but at an upwards angle of at least 5 % (figure 5).
Page 65
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 3.4. INLET AIR Air from the environment, required for correct combustion, must be refreshed with new air, through opening in the wall, slot in boiler room doors or grid on the window. This will ensure proper combustion and proper boiler operation.
Page 66
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 Power supply cable must never reach 80 °C above ambient temperature. If you want to connect the boiler directly to electrical network, you must install a bipolar switch with minimum distance of 3 mm between contacts, suitable for required electrical voltage and in accordance with regulations in force.
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 BOILER COMMISSIONING Boiler commissioning can be performed only by a manufacturer authorized technician, otherwise the warranty is void. INSTRUCTIONS FOR SAFETY OF PERSONS, ANIMALS AND PERSONAL PROPERTY We wish to inform the installer on some general guidelines, which must be complied with for correct installation of pellet boiler.
Page 68
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 Always use original spare parts. Do not wait for boiler components to wear out before replacing them. Replacing a worn-out part, before it malfunctions, helps prevent injuries, caused by sudden failure of a component, which can seriously jeopardize persons and/or their property.
Page 69
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 DO NOT use the pellet boiler in case of operation malfunction or other irregularities, abnormal noises and/or suspicious faults and IMMEDIATELY contact authorized service personnel; DO NOT spill water on the boiler, as well as put out fire in the combustion chamber with water;...
Page 70
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 Vacuum ashes from the combustion at least once every ten days or at each used pellet container (only when the boiler is cool) (figure 10). Vacuum and carefully clean the combustion container at least once every ten days or at each used pellet container (only when the boiler is cool) (figure 10).
Page 71
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 If you require any explanation do not hesitate and contact your installer. Because the manufacturer has no control of the installer's work, he cannot guarantee performance of his work and maintenance.
Page 72
ADDITIONAL MAINTENANCE Your pellet boiler is a heat generator which uses pellets. Therefore, it requires a special type of maintenance by authorized personnel of company Gorenje d.d. each year. Regular annual maintenance keeps the combustion device in good condition, ensures greater efficiency, retains warranty and extends life expectancy of the device.
Page 73
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 ATTENTION Do not use fine cut wood to ensure operation and safety of the boiler. ATTENTION Do not use the pellet boiler as an incinerator. PELLET QUALITY IS VERY IMPORTANT The pellet boiler is designed for use with pellets.
Page 74
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 ATTENTION Persons with back injuries and pregnant women should avoid lifting pellet bags. ATTENTION The manufacture shall in no way be held liable for damages arising from the use of poor quality pellets, as well as for poor functioning of the boiler due to poor quality of used pellets.
Page 75
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 DESCRIPTION AND OPERATION OF CONTROL DEVICE DESCRIPTION OF KEYBOARD WITH DISPLAY (plastic keyboard) Upper display Indicator of Indicator of turned operating feeding on timer system screw UP and DOWN + and –...
Page 76
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 Display Function upper display shows boiler status, chosen menu and indicates dosing operation and operation in time programme lower display shows current time, value of settings and parameters and warning names spark plug operation indicator pump operation indicator...
Page 77
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 Button Function ON/OFF button Press and hold to turn the boiler on/off. Short press to return to basic display. Button UP Press during operation to increase set power. When pressing MENU button beforehand, this button increases desired water temperature in the boiler.
Page 78
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 Button – Press during operation to decrease desired water temperature in the boiler for a degree. 9.1. BOILER DURING OPERATION The display shows current operation phase (e.g. TestFire, HeatUp etc.). Upper display shows set and actual boiler power alternately every 5 seconds.
Page 79
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 ATTENTION By pressing and holding MENU button for 2 seconds (release the button when tH20 displays), the display indicates current water temperature in the boiler. By pressing button UP or button DOWN you select display of other temperatures and fan status .
Page 80
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 Figure 12: Diagram of timer settings 9.5. INDICATIONS AND MESSAGES ON DISPLAY Indication on Explanation of message and status of the boiler display The boiler is at a standstill. 1 2 :5 3 The boiler is at a standstill, but the time programme is active and will start °...
Page 81
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 In ignition phase, when the dosing screw filled the firebox, spark plug heats He a t pellets to ignition. After Heat up phase, the boiler ignites pellets. No dosing in this phase. Fu e l IGNI At the end of ignition phase, the boiler shuts off the spark plug and tests, if the...
Page 82
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 No signal of smoke gases sensor. Contact the service centre. AL AR No signal of firebox temperature. Contact the service centre. AL AR No signal of flow sensor or the fans do not operate properly. Contact the service ALAR centre.
Page 83
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 Menu selection View 14. Status of safety pressure control. Yes 1. Water 8. Smoke fan speed means OK, No means temperature in boiler error 2. Ambient 15. Status of digital input 1 (D1): temperature (if the 9.
Page 84
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 ALARM STATUSES unsuccessful ignition Fill the Are there pellets in the container with container? pellets Deactivate protection by pressing button Is STB turned on (protection active)? service person Clean the gasket pot Is the gasket pot celan? 1.
Page 85
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 out of fuel Fill the Are there pellets in the container with container? pellets Deactivate protection by Is STB turned on (protection pressing button active)? service person 1. Check pressure control with artificially created negative pressure Does mechanic pressure 2.
Page 86
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 air flow through burner 1. Check air intake into space 2. Check entry point of air into boiler Clogged air intake? 3. Check dirtiness of burning container and space beneath it service person 1.
Page 87
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 fault of safety pressure control 1. Check air intake into space 2. Check entry point of air into boiler Clogged air intake? 3. Check dirtiness of burning container and space beneath it service person 1.
Page 88
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 safety thermostat is clogged 1. Cool the boiler and press button STB again 2. If the error remains, check set boiler temperature 3. Check heat take-off from boiler Is boiler temperature above 95 degrees? 1.
Page 89
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 electronics does not detect smoke gases sensor service person Replace sensor Is the sensor connected? Connect sensor to correct position of electronics electronics does not detect firebox temperature sensor service person Replace sensor Is the sensor connected?
Page 90
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 electronics does not detect boiler water sensor Replace sensor Is the sensor connected? Connect sensor to correct position of electronics electronics does not detect return water sensor service person Replace sensor Is the sensor connected? Connect sensor to correct position of electronics...
Use only original spare parts. WARRANTY TIME CONDITIONS: Warranty for all Gorenje products is valid for 24 months from the date of first start-up, given that a regular maintenance inspection is performed no later than 24 months from the date of start-up.
Page 92
If it is damaged, immediately inform the salesman, and record the damage on admission document or supply order; If the start-up was performed by a company without appropriate authorization for Gorenje products; If the product has been tampered with or repaired by an unauthorized person;...
Page 93
As representative/salesman is considered any natural person or legal entity authorized for sales of products to end users of this warranty. NOTE: Gorenje d.d. shall not be held liable for any damage and consequences, even if these are a consequence of replacement of malfunctioning part of the boiler.
Page 94
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 TECHNICAL CHARACTERISTICS OF MODEL ECOLOGIC 30 Minimal Nominal Thermal power 8,65 kW 30,80 kW Efficiency 91,92 % 91,94 % Pellet consumption per hour 1,92 kg/h 6,82 kg/h Burning time with 1 filling of container (approx.) 93,8 h 26,4 h...
Page 95
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 Voltage 220 V Current at maximum electrical consumption during boiler operation 1,80 A frequency 50 Hz Maximum consumption of power during boiler operation 78,5 W Minimum consumption of power during boiler operation Maximum consumption of power during boiler ignition 328,5 W Safety level...
Page 96
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 __________ Instructions for installers __________ This part of the instructions is intended solely for installer and contains all key information for installation and connection of combustion device ECOLOGIC 30.
Page 97
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 Boiler room flue installation Figure 14: Boiler room example...
Page 98
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 Boiler parts Remove the back coating to access components at the back of the boiler (figure 16). Figure 15: Important boiler parts...
Page 99
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 Figure 16: Removing back cover (net) Remove the back coating (net), which covers all the elements of the boiler, by unscrewing all the bolts. Access to boiler parts from the back is now possible.
Page 100
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 Boiler connection instructions To connect boiler ECOLOGIC 30 to central heating system you must check: It is necessary to take into account the installations of non-return valve spring (or other locking elements) which automatically prevent uncontrolled circulation of the heating medium through the boiler by natural gravitational path.
Page 101
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 boiler and system; in the time of filling "there cannot be a closing element, which could pre- vent indication of pressure in the boiler in the time of filling"). On the right side of ECOLOGIC 30 (see figure 17, page 49) is a provided DN20 connection for filling release tap.
Page 102
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 Figure 17 Figure 18 Figure 19 Figure 20 Figure 21: Activating thermal safety...
Page 103
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 CONNECTION SCHEMES 4.1. SCHEME NR.1: HEATING ONLY Connection scheme 1...
Page 104
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 Electrical scheme 1...
Page 105
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 4.2. SCHEME NR.2: HEATING HOUSE + HOUSEHOLD HOT WATER Connection scheme 2...
Page 106
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 Electrical scheme 2...
Page 107
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 4.3. SCHEME NR.3: HEATING WITH MULTIPLE SYSTEMS This type of connection always requires a hydraulic switch. Connection scheme 3...
Page 108
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 Electrical scheme 3...
Page 109
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 __________ Instructions for first start-up __________...
Page 110
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 ECOLOGIC 30 is a combustion device for heating with pellets. Benefits of combustion device ECOLOGIC 30 lie in advanced technology that enables automatic identification of oxygen contents in air, automatic identification of flue draught and automatic identification of pellet quality.
Page 111
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 When the installer makes the connection to central heating system, to chimney with flue connection and to electrical network in accordance with instructions for installers, the boiler is ready for start-up. After checking details from instructions for installers, combustion device ECOLOGIC 30 can be commissioned with ON/OFF button (see figure 22) by the installer, who installed the device.
Page 112
ECOLOGIC 30 | instructions for use, maintenance and installation | June 2015 Displayed information is: tH2O temperature of heating water in the boiler rH2O temperature of heating water on return tFLU temperature of smoke gases ((H2O )+30-90°C), ...