IPWR104HR-60/100W Isolated PC/104 Power supply module User’s Manual ISO 9001 and AS9100 Certified BDM-610020007 Rev. D...
Page 2
IPWR104HR-60/100W Power supply module User’s Manual RTD Embedded Technologies, INC. 103 Innovation Blvd. State College, PA 16803-0906 Phone: +1-814-234-8087 FAX: +1-814-234-5218 E-mail sales@rtd.com techsupport@rtd.com web site http://www.rtd.com IPWR104HR RTD Embedded Technologies, Inc...
Page 3
All rights reserved Printed in U.S.A. The RTD Logo is a registered trademark of RTD Embedded Technologies. cpuModule and utilityModule are trademarks of RTD Embedded Technologies. PhoenixPICO and PheonixPICO BIOS are trademarks of Phoenix Technologies Ltd. PS/2, PC/XT, PC/AT and IBM are trademarks of International Business Machines Inc.
Power supply shuts down after running for some time..................25 Power supply power cycles............................25 The voltage at my CPU is too low for it to start ..................... 25 CHAPTER 6 RETURN POLICY AND WARRANTY ........... 26 Return Policy ................................26 IPWR104HR RTD Embedded Technologies, Inc...
Page 7
List of Illustrations ................................Illustrations Fig. 1-1: IPWR104HR integrated in a PC/104 RTD cpuModule stack Fig. 1-2: 19” Eurocard rack installation with an integrated PC/104 RTD dataModule and EUROCARD cpuModule computer system Fig. 1-3: IPWR104HR power supply power connections Fig. 2-1:...
-5V is an 100mA LDO cascaded off the -12V converter. The IPWR104HR can be “switched off” from a remote source. If this switch (X1 jumper) is opened the power supply will become inactive while still powered. IPWR104HR RTD Embedded Technologies, Inc...
IPWR104HR directly on a PC/104 compatible computer using the onboard mounting holes. Care must be taken to ensure adequate heat dissipation from the onboard heat sink in high output power installations. (RTD can offer heat sinks for the DC/DC converter).
If you have any problems installing or using this board, contact our Technical Support Department (814) 234 8087. Alternatively, send a FAX to (814) 234 5218 or Email to sales@rtd.com. When sending a FAX or Email request please include the following information: Your company' s name and address, your name, your telephone number, and a brief description of the problem.
Check the input power to the board is in the range of 18 to 36V DC or 36 to 72V DC. • Apply power to your IPWR104HR, and make sure the diagnostic LED’s will indicate correct operation. IPWR104HR RTD Embedded Technologies, Inc...
The PC/104 system can easily be inserted into a 19" rack installation using the CPU as a "form factor adapter". Assemble your PC/104 data modules on a RTD single board EUROCARD computer and install the system in a 19" enclosure.
X1: Remote ON/OFF , close this jumper to enable the IPWR104HR • Note: The X1 jumper has been replaced by a wire to improve vibration performance. If the customer requires the remote ON/OFF function, contact the factory for details. IPWR104HR RTD Embedded Technologies, Inc...
The main +5V converter for the computer and PC/104 bus • The secondary power output converters +12V and -12V for peripheral devices (also -5V) • Onboard status LED’s • Fuses and protection • Output power calculations • Power derating of the +5V converter IPWR104HR RTD Embedded Technologies, Inc...
Page 17
Fig. 2-1 Block diagram of the IPWR104HR-L (-H has a 33-75V input range) IPWR104HR RTD Embedded Technologies, Inc...
TB3. The -12V power at 6 Watts is available from terminal block TB4. (See previous section for locations.) . The +12V and -12V supplies also power the PC/104 bus. -5V is an 100mA LDO cascaded off the -12V (only on ISA bus). IPWR104HR RTD Embedded Technologies, Inc...
The maximum specified output power may not be available if the ambient temperature rises, and in this case additional heat sinking or airflow may be necessary. See the following passage for more information on thermal behavior of your IPWR104HR. IPWR104HR RTD Embedded Technologies, Inc...
Page 20
Step response 10% and 72% loads at 500 Hz. Stepping load from 2 Amps to 14.4 Amps. Step load rise time 200 nSec. Peak deviations stay within 7%. Deviation duration 115.0 uSec. Measured at the 5V output. IPWR104HR RTD Embedded Technologies, Inc...
Operating temperature range 0 to +70° C -40 to +85 C in IDAN or HiDAN Base plate temperature (Max) +100° C Internal power dissipation IPWR104HR-L 14W (Max) (cooling required) Internal power dissipation IPWR104HR-H 22.51W (Max) IPWR104HR RTD Embedded Technologies, Inc...
The voltage at my CPU is too low for it to start Check the voltage drop over the bus Try moving the CPU closer to the IPWR in the stack Remove boards from stack to isolate the board causing the power draw. IPWR104HR RTD Embedded Technologies, Inc...
We will not ship by next-day service without your pre-approval. Carefully package the product, using proper anti-static packaging. Write the RMA number in large (1") letters on the outside of the package. Return the package to: RTD Embedded Technologies, Inc. 103 Innovation Blvd. State College PA 16803-0906 IPWR104HR...
Page 28
During the one year warranty period, RTD Embedded Technologies will repair or replace, at its option, any defective products or parts at no additional charge, provided that the product is returned, shipping prepaid, to RTD Embedded Technologies. All replaced parts and products become the property of RTD Embedded Technologies.
Page 29
RTD Embedded Technologies, Inc. 103 Innovation Blvd. State College PA 16803-0906 Our website: www.rtd.com IPWR104HR RTD Embedded Technologies, Inc...
Need help?
Do you have a question about the IPWR104HR-60 and is the answer not in the manual?
Questions and answers