MODEL TS8010 - 10.4" COLOR TOUCHSCREEN

GENERAL DESCRIPTION

The TS8010 Operator Interface Terminal combines unique capabilities
normally expected from high-end units with a very affordable price. It is built
around a high performance core with integrated functionality.
The TS8010 is able to communicate with many different types of hardware
using high-speed RS232/422/485 communications ports and Ethernet 10 Base
T/100 Base-TX communications. In addition, the TS8010 features USB for fast
downloads of configuration files and access to trending and data logging. A
CompactFlash socket is provided so that Flash cards can be used to collect your
trending and data logging information as well as to store larger configuration files.
In addition to accessing and controlling of external resources, the TS8010
allows a user to easily view and enter information. Users can enter data through
the touchscreen or front panel 8-button keypad.
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the
manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
Do not use the controller to directly command motors, valves, or other
actuators not equipped with safeguards. To do so can be potentially harmful to
persons or equipment in the event of a fault to the controller.
The protective conductor terminal is bonded to conductive
parts of the equipment for safety purposes and must be
connected to an external protective earthing system.
WARNING - EXPLOSION HAZARD - SUBSTITUTION
OF ANY COMPONENT MAY IMPAIR SUITABILITY
FOR CLASS I, DIVISION 2
CAUTION: Risk Of Danger.
Read complete instructions prior to
installation and operation of the unit.
CAUTION: Risk of electric shock.
 CONFIGURED USING DSI8000 SOFTWARE
 UP TO 5 RS-232/422/485 COMMUNICATIONS PORTS
(2 RS-232 AND 1 RS-422/485 ON BOARD, 1 RS-232 AND 1
RS-422/485 ON OPTIONAL COMMUNICATIONS CARD)
 10 BASE T/100 BASE-TX ETHERNET PORT TO NETWORK
UNITS AND HOST WEB PAGES
 USB PORT TO DOWNLOAD THE UNIT'S CONFIGURATION
FROM A PC OR FOR DATA TRANSFERS TO A PC
 UNIT'S CONFIGURATION IS STORED IN NON-VOLATILE
MEMORY (32MBYTE FLASH)
®
 COMPACTFLASH
SOCKET TO INCREASE MEMORY CAPACITY
 10.4-INCH TFT 32K VGA 640X480 PIXEL LCD
 OUTDOOR UNIT WITH UV RATED OVERLAY AVAILABLE
 8-BUTTON KEYPAD FOR ON-SCREEN MENUS
 THREE FRONT PANEL LEDS
 POWER UNIT FROM 24VDC ±20% SUPPLY
 RESISTIVE ANALOG TOUCHSCREEN
CONTENTS OF PACKAGE
- TS8010 Operator Interface.
- Panel Gasket.
- This hardware bulletin.
- Template for panel cutout.
- Hardware packet for mounting unit into panel.
- Terminal block for connecting power.
ORDERING INFORMATION
DESCRIPTION
10.4" TFT VGA Display Operator Interface (indoor), USB
Host, Isolated Comms
CANopen Option Card
Profibus DP Option Card
DeviceNet Option Card
FireWire Option Card
CompactFlash is a registered trademark of CompactFlash Association.
1
Bulletin HP471055U010
Issue 1.0
Drawing No. LP0877X
Effective 10/11
PART NUMBER
TS8010/00/02
8000/CB/00/00
8000/PB/00/00
8000/DN/00/00
8000/FA/00/00

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TS8010 and is the answer not in the manual?

Questions and answers

Summary of Contents for Parker TS8010

  • Page 1: General Description

    - Panel Gasket. around a high performance core with integrated functionality. - This hardware bulletin. The TS8010 is able to communicate with many different types of hardware - Template for panel cutout. using high-speed RS232/422/485 communications ports and Ethernet 10 Base - Hardware packet for mounting unit into panel.
  • Page 2: Specifications

    Note: Shock according to IEC 68-2-27: Operational 35 g, 11 msec in 3 directions. 1. The TS8010’s circuit common is not connected to the enclosure of the Altitude: Up to 2000 meters. unit. See “Connecting to Earth Ground” in the section “Installing and 9.
  • Page 3: Mounting Instructions

    WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA Each TS8010 has a chassis ground terminal on the back of the unit. Your unit IS KNOWN TO BE FREE OF IGNITABLE CONCENTRATIONS.
  • Page 4: Ethernet Communications

    DSI8000 is installed. This may have already been accomplished if your TS8010 was configured using the USB port. Once the driver is installed, connect the TS8010 to your PC with a USB cable, and follow the “Mounting the CompactFlash” instructions found in the DSI8000 user manual.
  • Page 5 ISOLATED RS232 HOST B PORT B 130K ISOLATED ISOLATED Note: All Parker - SSD Drives devices connect A to A and B to B. AUXILIARY ETHERNET ETHERNET Examples of RS485 2-Wire Connections TS to Parker - SSD Drives RJ11 Connections...
  • Page 6: Backlight Replacement

    DSI8000 SOFTWARE KEYPAD DSI8000 software is available as a free download from Parker - SSD Drives’ The TS8010 keypad consists of eight keys for on-screen menus. website. The latest version of the software is always available from the website, and updating your copy is free.
  • Page 7 A battery is used to keep time when the unit is without power. Typical accuracy of the TS8010 time keeping is less than one minute per month drift. The battery of a TS8010 unit does not affect the unit’s memory, all configurations BATTERY and data is stored in non-volatile memory.
  • Page 8: Optional Communication Card

    CompactFlash can be used for configuration transfers, larger configurations, data logging, and trending. Information stored on a CompactFlash card by a TS8010 can be read by a ® card reader attached to a PC. This information is stored in IBM (Windows ) PC compatible FAT16 file format.