● Change target luminance and range of the Auto adjustment
W/B equipment
- 50/60R5
Target luminance
Range
* Manual W/B process (using adjusts Remote control)
- Please Adjust in AV 1 MODE, Turn off Energy Saving Mode.
1) Enter 'PICTURE RESET' on Picture Mode, and then turn
off Fresh Contrast and Fresh colour in Advanced Control
2) After enter Service Mode by pushing "ADJ" key,
3) Enter White Pattern off of service mode, and change off
-> on.
4) Enter "W/B ADJUST" by pushing "►" key at "3. W/B
ADJUST".
* Gain Max Value is 192. So, Never make any Gain Value
over 192 and please fix one Value on 192, between R, G
and B.
Min
R-GAIN
0
G-GAIN
0
B-GAIN
0
* Auto-control interface and directions
(1) Adjust in the place where the influx of light like floodlight
around is blocked. (Illumination is less than 10ux).
(2) Measure and adjust after sticking the Color Analyzer (CA-
100+, CA210) to the side of the module.
(3) Aging time
- After aging start, keep the Power on (no suspension of
power supply) and heat-run over 5 minutes
* Auto adjustment Map (RS232C)
No
Index
CMD1
1
Start
w
2
Gain Start
w
3
Gain End
w
4
Offset Start
w
5
Offset End
w
6
End
w
7
Medium R
j
8
Medium G
j
9
Medium B
j
10
Warm R
j
11
Warm G
j
12
Warm B
j
13
Cool R
j
14
Cool G
j
15
Cool B
j
16
Cool R,G,B
j
17
Medium
j
18
Warm
j
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
50
±23
Typ
Max
192
192
192
192
192
192
CMD2
Set ID
Data
b
0
00
b
0
10
b
0
1F
b
0
20
b
0
2F
b
0
FF
a
0
00~FF
b
0
00~FF
c
0
00~FF
d
0
00~FF
e
0
00~FF
f
0
00~FF
g
0
00~FF
h
0
00~FF
i
0
00~FF
j
0
00~FF
k
0
00~FF
l
0
00~FF
4.3. Serial number download & Model name D/L.
(1) Press "Power on" button of a service R/C.(Baud rate :
115200 bps)
(2) Connect RS232-C Signal Cable and start 'Option Check
Program Ver3.8'
(3) Scan serial Number and press 'F5' button.
(4) Check 'OK' on program 1) program.
(5) Press 'In start' button on SVC R/C, check Serial Number
and Model Name.
4.4. Check Tool Option and write Country
Group & Area Code(Option) D/L
- Refer to Table 3.3 insert tool option.
4.5. PING TEST
* In this case Network setting is on Manual Setting.
Connect : SET->LAN Port == PC->LAN Port
4.5.1. Equipment Setting
(1) Play the LAN Port Test PROGRAM.
(2) Input IP set up for an inspection to Test
* IP Number : 12.12.2.2
4.5.2. LAN PORT inspection (PING TEST)
* In this case Network setting is on Manual Setting.
(1) Play the LAN Port Test Program.
(2) connect each other LAN Port Jack.
(3) Play Test (F9) button and confirm OK Message.
(4) remove LAN CABLE