1-4. System Hook up Procedures
1.
Unscrew 2 screws and remove the EVR cover.
2.
Connect the 2 pcs. of 30 pin flat cables between
P101/P102 on the Measuring Board, and 2
connectors on the Connector Board. Make sure that
the contact surface of 2 pcs. of 30 pin Flat Cables
are inner side and direction of the Connection Board
is as shown in Figures E4. Then connect the
Extension board.
3.
Set the Connector Board with the 30 pin Cables to
the unit as shown in Figure E5. Make sure that the
direction of the Connection Board is correct as
shown in Figure E5.
Screws
Fig.E3
Fig.E4
4.
Connect the AC adapter or set the Battery to the
unit.
5.
Connect a 9 pin RS-232C cable between the
Measuring Board and RS-232C connector on
Personal Computer as shown in Figure E2.
6.
Supply DC6V to the Measuring Board (VFK1308P).
7.
Unless otherwise specified on the message of the
EVR software, set the switches on the Measuring
Board as shown in the table below.
NAME OF
SW REF.
SW
RS-232
SW101
Select
SW103
VTR Test
SW104
BST Test
SW106
REC I
SW107
Using halogen lamps in the camera room.
The camera adjustments should be performed under the
following lighting condition.
Color Temperature
Lumination
27
Fig.E5
SETTING POSITION
It is depend on the type of
the
cable
between
measuring board and PC.
*Ordinary 9pin RS-232C
Cross Cable:
D-SUB Position
*M4 RS-232C Cable:
M3 Position
L Position
NORMAL Position
OFF Position
CENTERT Position
Fig.E6
:3100K°
:1400Lux
the