OPERATOR MANUAL
IMPORTANT INFORMATION, KEEP FOR OPERATOR
This manual provides information for:
THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE.
READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND
WARNINGS CONTAINED IN THIS MANUAL.
NOTIFY CARRIER OF DAMAGE AT ONCE
It is the responsibility of the consignee to inspect the container upon receipt of
same and to determine the possibility of any damage, including concealed dam-
age. Unified Brands suggests that if you are suspicious of damage to make a
notation on the delivery receipt. It will be the responsibility of the consignee to file
a claim with the carrier. We recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.
1055 Mendell Davis Drive
Information contained in this document is known to be current and accurate at the time
Jackson, MS 39272
of printing/creation. Unified Brands recommends referencing our product line websites,
888-994-7636, fax 888-864-7636
unifiedbrands.net, for the most updated product information and specifications.
unifiedbrands.net
PART NUMBER PP EA0711 REV A (08/11)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ecoarch and is the answer not in the manual?

Questions and answers

Summary of Contents for Avtec ecoarch

  • Page 1 OPERATOR MANUAL IMPORTANT INFORMATION, KEEP FOR OPERATOR This manual provides information for: THIS MANUAL MUST BE RETAINED FOR FUTURE REFERENCE. READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL. NOTIFY CARRIER OF DAMAGE AT ONCE It is the responsibility of the consignee to inspect the container upon receipt of same and to determine the possibility of any damage, including concealed dam- age.
  • Page 2: Table Of Contents

    Table of Contents Types of Systems ................page 4 Installation Requirements for Avtec Ventilation Hoods ....page 5 Canopy Hoods ................page 5 UV Electrical .................. page 9 Exhaust Fans & Ducts ..............page 13 Control Panels ................page 14 Fresh Air Supply Fans ..............
  • Page 3 Retain this manual for future reference. NOTICE: Due to a continuous program of product improvement, Avtec reserves the right to make changes in design and specifications without prior notice. NOTICE: Please read the entire manual carefully before installation. If certain recommended procedures are not followed, warranty claims will be denied.
  • Page 4: Types Of Systems

    Surface, plenum and duct collar extinguishing systems may be factory supplied. ULTRAVIOLET (UV) SERIES The EcoArch Energy Efficient Ventilation UVc is a door assembly integrally installed in the exhaust plenum of an EcoArch canopy, consisting of UVc filtration system designed for use in the ventilation control of commercial cooking operations of listed hood systems.
  • Page 5: Installation Requirements For Avtec Ventilation Hoods

    ALL AVTEC VENTILATION SYSTEMS MUST BE INSTALLED IN ACCORDANCE WITH NFPA- canopies. Low side wall ventilators should be installed directly upon a Avtec base or on a VENTILATION HOODS 96, REMOVAL OF SMOKE AND GREASE-LADEN VAPORS FROM COMMERCIAL COOKING rerated wall.
  • Page 6 Installation Instructions ECOARCH CANOPIES EQUIPPED If your EcoArch hood comes equipped with an UV assembly please refer to the following steps. WITH UV ASSEMBLY General CAUTIONS & Guidelines • Installation of UV Exhaust canopies must be completed by HVAC ventilation system contractors or employees trained and qualified to do ventilation hood and exhaust system installation.
  • Page 7 Installation Instructions Figure 5 OM-ECOARCH 7...
  • Page 8 Installation Instructions Figure 5 Continued OM-ECOARCH...
  • Page 9: Uv Electrical

    UV light switch will terminate. THE POWER AT (TS-2) IS 115V/1/60. Connect one PLEASE ADHERE TO ALL ELECTRICAL side of the switch to terminal 1 and the other side of the switch to terminal 2. Please NATIONAL, STATE, AND LOCAL CODES. make sure the switch is connected to ground. OM-ECOARCH 9...
  • Page 10 Installation Instructions Figure 6a BALLAST BOX RELAY BOX OM-ECOARCH...
  • Page 11 Installation Instructions Figure 6b OM-ECOARCH 11...
  • Page 12 Installation Instructions Figure 6c OM-ECOARCH...
  • Page 13: Exhaust Fans & Ducts

    9. A duct transition should be provided below exhaust fan inlet. 10. The exhaust duct must be fluid welded to hood collar. 11. Make all necessary electrical connections and check fan for proper rotation. NOTE: Fan will exhaust air running in wrong direction. OM-ECOARCH 13...
  • Page 14: Control Panels

    Electrical back draft damper is recommended in cold climates. 9. Bolt or screw fan to fan curb. 10. Make all necessary electrical connections and check fan for proper rotation. NOTE: Fan will supply air running in wrong direction. *Dependent on local code requirements. OM-ECOARCH...
  • Page 15 Installation Instructions FOR CONTROL PANEL (IF PROVIDED) Figure 7 OM-ECOARCH 15...
  • Page 16: Side Skirts

    2. Skirts are to overlap the outside of the hood. Bolts and acorn nuts should be attached per the drawing (stainless bolts and acorn nuts supplied). 3. Skirt flange should be screwed to the wall (screws not provided). Figure 8 OM-ECOARCH...
  • Page 17: Top Enclosure Panels

    2. Slide enclosure panel under clips. 3. If enclosure panels are installed on one or more hoods butted end to end, the butting ends of the front enclosure panels should be bolted together. Figure 9 OM-ECOARCH 17...
  • Page 18: Stainless Steel Wall Panels

    4. Slip one end of wall panel into seam strip, pull out middle of panel and slip other end of panel into other seam strip. Gently apply pressure over entire wall panel to secure to wall. Wall bands for side walls are provide with 1” return bend, which is to be located behind rear wall panels. OM-ECOARCH...
  • Page 19: Operation Instructions Start-Check-Balance

    4. Adjust speed of exhaust fan to obtain proper air velocities and CFM through grease filters. SUPPLY FAN OR 1. Start the supply fan and/or make-up unit only. Do not run the exhaust fan. MAKE-UP AIR UNIT 2. Refer to drawings or UL information label on hood for proper CFM requirements. OM-ECOARCH 19...
  • Page 20: Final Air Balance Make-Up Air Hood

    6. If all vapors are not totally captured, fine tune the system by adjusting the air volume control damper installed in the supply collar. Slightly reduce the amount of supply air directed under the hood until full capture is obtained. OM-ECOARCH...
  • Page 21: Periodic Maintenance

    UV lamp exterior using a dry towel and a non-detergent cleaning agent such as sanitizing solution or white vinegar. IMPORTANT: Do not allow cleaner to run into lamp fittings or socket enclosures. IMPORTANT: UV System will not work properly without daily cleaning of the UV lamp. OM-ECOARCH 21...
  • Page 22: Parts List

    Parts List EcoArch Parts ITEM NO. AVTEC PART NO. DESCRIPTION HD HDL010 4” Chrome Handle AS SEAL395 3/8” Quickseal AS GLB0201 Incandescent Work Light Globe AS FIX0201 Incandescent Work Light Cage AS LGT1220 3’-0” Fluorescent Work Light AS LGT1420 4’-0” Fluorescent Work Light AS LGT1020 2’-0”...
  • Page 23 Service Log Model No: Purchased From: Serial No: Location: Date Purchased: Date Installed: Purchase Order No: For Service Call: Date Service Performed Performed By OM-ECOARCH 23...
  • Page 24 1055 Mendell Davis Drive • Jackson MS 39272 888-994-7636 • 601-372-3903 • Fax 888-864-7636 unifiedbrands.net PART NUMBER PP EA0711 REV A (08/11) © 2011 Unified Brands. All Rights Reserved. Unified Brands is a wholly-owned subsidiary of Dover Corporation.