C5 is controller maximum operating current adjustment setting (tiny-adjustment of
limit current value), the default value is 10, setting range is 0-10, hold
or
button (DOWN) shortly for selection.
C5 parameter definition table:
C5 value
00
01
02
03
04
05
06
07
08
09
10
When C5 setting is 10, maximum current value is controller maximum operating
current value (ie, limit current value); when setting is 9, maximum current value divided by
1.10, when setting is 8, maximum current value divided by 1.15 and so on.
After finishing C5 parameter setting, hold
current set values and enter C6 parameter setting interface.
○
C6 Backlight Brightness Adjustment Setting
Enter C6 parameter setting interface after C5 parameter setting is finished, C6
parameter column flashes.
ELECTRIC BICYCLE METER KT—LCD5 Product User Manual
C5 parameter setting interface
Three level slow start/ Maximum current value
Two level slow start/ Maximum current value
One level slow start/ Maximum current value
Maximum current value(A)
Maximum current value÷2.00
Maximum current value÷1.50
Maximum current value÷1.33
Maximum current value÷1.25
Maximum current value÷1.20
Maximum current value÷1.15
Maximum current value÷1.10
Maximum current value
button (SW) shortly to save the
- 26 -
button (UP)