Data Video RMC-400 Instruction Manual

Replay controller

Advertisement

Quick Links

1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RMC-400 and is the answer not in the manual?

Questions and answers

Summary of Contents for Data Video RMC-400

  • Page 2: Table Of Contents

    Table of Contents FCC COMPLIANCE STATEMENT ............. 4 WARNINGS AND PRECAUTIONS ........... 4 WARRANTY ................. 5 ................. 5 TANDARD ARRANTY ................. 5 ARRANTY DISPOSAL..................6 INTRODUCTION..............7 ..................7 EATURES SYSTEM DIAGRAM ..............8 CONNECTIONS AND CONTROLS ..........9 ..................9 ANEL ................
  • Page 3 FIRMWARE UPGRADE ............23 DIMENSIONS ............... 24 SPECIFICATIONS ..............25 SERVICE AND SUPPORT .............. 26 Disclaimer of Product & Services The information offered in this instruction manual is intended as a guide only. At all times, Datavideo Technologies will try to give correct, complete and suitable information. However, Datavideo Technologies cannot exclude that some information in this manual, from time to time, may not be correct or may be incomplete.
  • Page 4: Fcc Compliance Statement

    FCC Compliance Statement This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation.
  • Page 5: Warranty

    When liquid has spilled into the unit; When the product has been exposed to rain or water; When the product does not operate normally under normal operating conditions. Adjust only those controls that are covered by the operating instructions in this manual; improper adjustment of other controls may result in damage to the unit and may often require extensive work by a qualified technician to restore the unit to normal operation;...
  • Page 6: Disposal

    Disposal For EU Customers only - WEEE Marking This symbol on the product indicates that it will not be treated as household waste. It must be handed over to the applicable take back scheme for the recycling of Waste Electrical and Electronic Equipment.
  • Page 7: Introduction

    Recorder. It allows the user to capture any specific desired scenes during any sports game. Once the special scene is captured, the user can edit and replay the clip using the RMC-400. Furthermore, the RMC-400 provides the user with the capabilities of saving the captured scenes to the disk and loading previously saved clips for replay.
  • Page 8: System Diagram

    System Diagram...
  • Page 9: Connections And Controls

    Connections and Controls Rear Panel Power Switch The power switch turns ON / OFF the device. DC IN DC in socket connects the supplied 12V PSU. The connection can be secured screwing outer fastening ring of the DC In plug to the socket.
  • Page 10: Control Panel

    Control Panel Device Enable Buttons Press the “DEV 1 to 4” buttons to activate the corresponding HDR-10 device for control. Press the button again to deactivate. Enabling of multiple devices is possible. Up to four HDR-10 Replay Recorder devices can be controlled at the same time.
  • Page 11 Replay Mode Pressing the REPLAY button enters the HDR-10 recorder device into the Replay mode. Recall Mode Pressing the “RECALL” button opens the on- screen recall menu, which allows the user to retrieve a clip for replay. The user can choose to either just replay the selected clip or append the selected clip to the current replay clip.
  • Page 12 GO TO MARK / SHORT Button In Trim mode, the “GO TO MARK” button toggles between Go To Marker and Drop Marker modes. This button is disabled in Replay mode. In Capture mode, this button acts as the “SHORT” button for quick capture of a short- length clip.
  • Page 13 T-Bar T-Bar sets the speed of Replay playback. The speed ranges from 0% to 400%. In Replay and TRIM mode, push the T-Bar to the position that corresponds to the desired speed. At speed 0%, the T-Bar is at its resting position leaning toward the user.
  • Page 14: Modes Of Selection

    3. Replay Mode Where the selected highlight is replayed on the PGM OUT port. In these three modes, the RMC-400 Replay Control Center provides dedicated buttons for quick access and control. Recall mode Where a saved clip is selected and replayed as a single clip or an appended clip;...
  • Page 15: Trim

    In Capture mode, the buttons depicted as follows will turn red, allowing the user to perform video capture operations. The “MARK IN” button drops the start cue to set the start point of a particular replay clip and marks the beginning of a possible video highlight to be replayed. Pressing the “SHORT”, “MEDIUM”...
  • Page 16: Replay

    SSD media as an uncompressed .MOV file by pressing the “SAVE CLIP” button. Replay To exit Trim mode, press the “REPLAY” button on the RMC-400 to enter the HDR-10 into Replay mode. The buffer line has also changed colour to blue to quickly confirm the mode has changed.
  • Page 17: Recall

    OFF. Recall To recall a previously saved clip, press the “RECALL” button on the RMC-400 to open an on- screen menu on the AUX output display. In this menu-driven Recall mode, browse the on-screen menu by rotating the jog wheel and press the “ENTER”...
  • Page 18 To browse the main on-screen menu, simply rotate the jog wheel and press the “ENTER” button to select a particular option. Press the “ENTER” button again to exit an option back to the main menu. The main menu options are describe in the table below. MENU Items Parameters Descriptions...
  • Page 19 Sets the time code. FORMAT MEDIA Select YES to format the storage media. FIRMWARE This FIRMWARE UPGARDE menu selection is for upgrading HDR-10 UPGRADE firmware. The RMC-400 FW upgrade procedure is described in the Firmware Upgrade section of this manual.
  • Page 20: Applications

    Applications In this section, we provide three examples of how you can use the RMC-400 to operate the HDR-10 Highlight Replay Recorder. Saving an edited clip or highlight to MOV file The HDR-10 only saves the marked clip/highlight on the buffer line to the removable SSD as an uncompressed MOV file.
  • Page 21: Recalling A Previously Saved Clip

    Recalling a previously saved Clip On the RMC-400 control panel, press the “MENU” button. Rotate the jog wheel to browse to the “SELECT BIN” option on the on-screen main menu and press the “ENTER” button to enter the option. Again, rotate the jog wheel to cycle through the BIN numbers and press the “ENTER”...
  • Page 22: Gpi Connections

    GPI Connections The RMC-400 can be controlled by external GPI trigger signal via simple contact closure GPI switch. The GPI interface is a 3.5mm Jack Socket which is situated on the rear panel of the RMC- 400. Contact closure between the Outer and Inner contacts on the jack plug will trigger a user selected event.
  • Page 23: Firmware Upgrade

    Format the USB drive to FAT32. Copy image file RMC400.bin to the formatted USB drive. Locate the FW Upgrade USB port on the back panel of the RMC-400. While power OFF, insert the USB drive into the “FW Upgrade” USB port.
  • Page 24: Dimensions

    Dimensions All measurements in millimeters (mm)
  • Page 25: Specifications

    Specifications Interfaces Connection Four mini-USB ports Control T-Bar Jog / Shuttle Dialer Software Update USB Type A...
  • Page 26: Service And Support

    Service and Support...