OWNER’S MANUAL ELECTRIC AIR COMPRESSOR SET MODEL A16...
Page 2
PREFACE Thank you for purchasing products from EASTERN TOOLS & EQUIPMENT, INC. We appreciate your business. The following manual is only a guide to assist you and is not a complete or comprehensive manual of all aspects of maintaining and repairing your air compressor.
TABLE OF CONTENTS SAFETY PRECAUTIONS AIR COMPRESSOR HAZARDS ELECTRICAL SAFETY VENTILATION RISK FROM INJURY ASSEMBLY INSTALLATION INSTRUCTIONS ON SETTING UP YOUR UNIT GROUNDING INSTRUCTIONS EXTENSION CORDS OPERATION KNOWING YOUR AIR COMPRESSOR DESCRIPTION OF OPERATION HOW TO USE YOUR UNIT MAINTENANCE MAINTENANCE SCHEDULE CHECKING THE SAFETY VALVE DRAINING THE AIR TANK...
SAFETY PRECAUTIONS AIR COMPRESSOR HAZARDS • It is normal to have some sparks within the motor and pressure switch. • Do not let the compressor come into contact with flammable vapors, as the sparks from the motor and pressure switch may ignite the flammables and cause an explosion. Always operate the compressor in a well-ventilated place free of flammable vapors.
• Authorized service center personnel should perform repairs. • Portable compressors can fall from tables or rooftops causing serious injuries or death to the operator. Always operate the compressor in a stable secure position to prevent accidental movement of the unit. Do not operate the compressor on a roof or other elevated positions.
INSTALLATION INSTRUCTIONS ON SETTING UP YOUR UNIT To begin setting up your compressor • Begin setting up the air compressor in clean, dry, and well-ventilated area. • Keep the compressor at least 1 foot away from the wall or other objects that may interfere with the flow of air.
EXTENSION CORDS It is recommended that more air hose be used instead of an extension cord. Using more extension cord will cause a voltage drop resulting in power loss to the motor. If an extension cord must be used, verify that it is: •...
Page 8
Safety Valve: If the pressure switch is malfunctioning and does not turn the compressor off after the pressure in the tank is too high, there is a safety valve that will protect against high pressure by “popping out” at its factory set pressure (slightly higher than the pressure switch “cut-out setting”).
Air Intake Filter: This filter cleans the air that comes into the air compressor pump. This filter should always be clean and free from debris. Check Valve: The check valve permits air to enter the tank when the air compressor pump is pumping air.
MAINTENANCE MAINTENANCE SCHEDULE Before Daily Every 8 Every Every each use after each hours 40 hours hours Check safety valve Drain tank Oil Leaks Check Oil Change Oil Air Filter CAUTION Before performing any type of servicing, please be sure to disconnect the power source from the compressor and drain all air from the air compressor.
DRAINING THE AIR TANK • Put the On/Auto/Off switch to the “Off” position. • Pull the regulator knob out and turn the knob until the outlet pressure reads zero. • Remove all the air tools and accessories connected to the air compressor. •...
AIR FILTER-INSPECTION AND REPLACEMENT WARNING Before servicing your compressor, please let the compressor cool down. When removing parts from the compressor, there are hot surfaces that can cause severe burns. Dirty air filters will bring down the compressors operating performance. Keep the air filter clean at all times.
TECHNICAL SPECIFICATIONS Technical specifications in English units Model Number Maximum pressure 115 PSI SCFM @ 40 PSIG 5.2 PSI SCFM @ 90 PSIG 4.0 PSI Peak Horsepower 2.5 HP Voltage 120 Volts Tank Capacity 4 Gallons Pump type Oil lubricated piston Weight 60 lbs Dimensions...
TROUBLESHOOTING Symptom Probable cause Corrective Action Low discharge 1. Air demand exceeds 1. Decrease air demand or use a larger pressure. pump capacity. capacity air compressor 2. Leaking air 2. Listen for high pitched escaping air. Apply soap solution to all fittings and connections.
Page 15
discharge air. humid weather. 2. Add a filter to reduce the amount of water in the air line. Tank does not 1. Worn check valve 1. Replace check valve hold pressure 2. Check all 2. Tighten when connections and compressors off fittings for leaks.
LIMITED WARRANTY Eastern Tools & Equipment, Inc. will repair or replace, free of charge, any part or parts of the compressor that are defective in material or workmanship or both. Transportation charges on parts submitted for repair or replacement under this Warranty must be borne by purchaser. This warranty is effective for the time period and subject to the conditions provided for in this policy.
Page 20
Normal wears: Engines and generators, like all mechanical devices, need periodic parts service and replacement to perform well. Warranty will not cover repair when normal use has exhausted the life of a part of an engine. Improper maintenance: The life of an engine or your equipment depends upon the conditions under which it operates, and the care it receives. Some applications, such as tillers, pumps, and rotary movers, are very often used in dusty or dirty conditions, which can cause what appears to be premature, wear.
APPENDIX List for comments from users Date of Manufacture Name of user Model Number Address of user Occupation Place of purchase Packaging conditions Operating conditions Parts Conditions Malfunction problem Opinions or suggestions Note: Please mail the above card to: Eastern Tools & Equipment, Inc. 12220 Rivera Rd, Suite B Whittier, CA 90606...