6-2 Constant Current Adjustment Method
1. Adjust by turning the voltage setting knob to desired voltage.
2. Press the CV/CC setting button down to light up the CC/CV setting
indicator.
3. Use a wire to shorten the (+) and (-) terminal at the output terminal.
4. Push the UP or DOWN button to obtain the desired current value.
5. When pushing and hold the UP or DOWN button over 0.8 sec, the
value will go up or go down continuously.
6. Release the shortend wire, connect the load to begin operation.
7. The setting of current value will be stored in the EEPROM after
power off.
8. The current value will be resumed by pushing the CV/CC button
when next power on.
12
4. PANEL DETAILS – SINGLE TYPE
Fig 2
9