Wolf-Guard SD-01 User Manual

Smoke sensor

Advertisement

Quick Links

USER MANUAL

EN
SD-01
Smoke Sensor
www.wolf-guard.com

Advertisement

Table of Contents
loading

Summary of Contents for Wolf-Guard SD-01

  • Page 1: User Manual

    USER MANUAL SD-01 Smoke Sensor www.wolf-guard.com...
  • Page 2: Box Content

    Introduction SD-01 smoke detector is designed to sense smoke that comes into the detector chamber. It does not detect gas, heat or flames. This smoke detector is designed to give you a early warning in case of start of fire thanks to its built-in siren. It enables you to save precious time and evacuate your house before the fire spreads.
  • Page 3: Product Overview

    Product Overview T e st Butto n A da pte r ( Optio n a l) Alarm Output Port Ba tte ry Slo t...
  • Page 4: Installation

    Features SD-01 adopts independent photoeletric sensor, can effectively detects smoke generated at the first stage of fire accident. The smoke enter the detector will make dispersion of light, and sensor will perceive the light intensity, when the light intensity reach preset level, sensor will launch fire alarm signal, red indicating light will flash and start buzzer warning sound.
  • Page 5 Useful indications Locations for placing smoke detectors for single floor with Figure1: only one bedroom. Kitchen Bathroom Toilets D in in g r o o m Bedroom L iv in g r o o m Figure2: Locations for placing smoke detectors for single floor with more than one bedroom.
  • Page 6 Figure3: If your house or apartment has several floors, install a detector en each floor. Bedroom Bedroom Bedroom Kitchen Living Room Basement Optim a l in sta lla tio n Here, we have useful tips for you: 1. Install the smoke detectors should be as close as possible to the center of the ceiling.
  • Page 7 3. Install a smoke detector at each end of a corridor giving access to bedrooms, if this corridor is more than 12-meters long. 4. In the cellar, install the detectors near the stairs. 5. Make sure no door nor any obstacle will prevent the smoke from reaching the detector.
  • Page 8: Operation

    Operation 1. Self-checking Self-checking function used for check power supply and circuit condition, once a week. Press Test button once, smoke detector emits emergency alarming code, led light flashing and siren start to sound. 2. Alarming Normally, the detector led light flashes every one minute. Detector will launch alarm when it detects smoke intensity reached preset level, flashes led light and sound siren for 1 minute, press Test button can stop the alarming code, detector will detect again...
  • Page 9: Specifications

    Specifications Model Number: Radio Frequency: SD-01 433 MHz Housing Material: Power Supply: ABS Plastic 9V Battery (included) Audio Alarm: Operation Condition: 85dB at 10ft Temperature -10 ° C ~ 60° C Sensor Type: Relative Humidity: ≤ 90% (Non-condensing) Photoelectric Transmitting Distance: Dimensions (L×W×H):...