Download Print this page

Advertisement

Quick Links

Air Compressor
Operation Manual
P20-M / P25-M / P30-M
255549 Rev.1
01/2014

Advertisement

loading

Summary of Contents for Ohio Medical P20-M

  • Page 1 Air Compressor Operation Manual P20-M / P25-M / P30-M 255549 Rev.1 01/2014...
  • Page 2: Safety Precautions

    PREFACE Thank you for purchasing an Ohio Medical air compressor. This manual introduces our Oil-less Air Compressors to users about all the information required for air compressor installation, operation and maintenance to ensure the most effi cient and trouble-free operation.
  • Page 3: Table Of Contents

    INDEX 1. General Description --------------------------------- 3 2. Installation --------------------------------------------- 3 3. V-Belt Adjustment ------------------------------------ 4 4. Safety Device ----------------------------------------- 4 5. Operation ---------------------------------------------- 5 6. Daily Maintenance ----------------------------------- 5 7. Periodical Maintenance ---------------------------- 6 8. Trouble Shooting ------------------------------------- 8 Appendix I Maintenance Record ----------------- 9 9.
  • Page 4: V-Belt Adjustment

    2.3 The machine must be leveled in all directions and must be fi rmly mounted. 2.4 The fl ywheel, which is also a fan for circulating air over the cylinder, should never be placed closer than 12” against the wall, so there is plenty of cooling air circulation. 2.5 Improper installation and maintenance may result in abnormal conditions such as: Insuffi...
  • Page 5: Operation

    4.3 Motor should follow regulations to be equipped with Magnetic switch and Overload relay to avoid the motor current over pre-setting limit. 5. Operation 5.1 Checks before starting Make sure that electrical connections comply with local electrical regulations. Check set bolts and nuts to be securely tight. Check V belt for proper tension.
  • Page 6: Periodical Maintenance

    7. Periodical Maintenance 7.1 Check the below parts periodically. 3000 6000 8000 Instructions (1 month) Check items months) months) months) Clean with brushes and  Intake Filter compressed air. (replace once 6 months.) Adjust and follow  V-belt loosen instructions in operation manual Tighten bolts(nuts) with ...
  • Page 7 Check the thickness of compression ring and guide ring periodically. Record the data in your service log. If the compressor has not run for a long time, it should be set on no-load running for at least 30 minutes per month to keep the bearings and related parts in regulator running condition.
  • Page 8: Trouble Shooting

    8. Trouble Shooting Action Problem Possible Check Repair Replace Valve assembly broken; or liner leaking Pressure Intake fi lter blocked can’t be raised Pipe leaking properly running Piston ring or cylinder worn V-belt loosen or worn-out Abnormal Fault unloading system pressure V-belt loosen or worn-out Set bolts loosen...
  • Page 9: Appendix I Maintenance Record

    Appendix I: Maintenance Record Hour Service Date Record Meter Tech 255549 (Rev.1) 02/2014...
  • Page 10 255549 (Rev.1) 01/2014...
  • Page 11 255549 (Rev.1) 02/2014...
  • Page 12 255549 (Rev.1) 01/2014...
  • Page 13 255549 (Rev.1) 02/2014...
  • Page 14: Replacement Parts

    10. Replacement Parts MODEL P20-M P25-M P30-M Compressor Module w/o Motor 230103 230104 230105 Complete Module Number 100-0225 100-0226 100-0227 Motor HP (60 Hz) Motor 244285 244286 244287 Temperature Switch (4) 211038 211038 211038 Auto Drain 3/8" NPT 211203 211203 211203 Relief Valve 1/2"...
  • Page 15 BLANK PAGE 255549 (Rev.1) 02/2014...
  • Page 16 © 2014 Ohio Medical Corporation. Th is document contains information that is proprietary and confi dential to Ohio Medical Corporation. Use of this information is under license from Ohio Medical Corporation. Any use other than that authorized by Ohio Medical Corporation is prohibited.

This manual is also suitable for:

P25-mP30-m