Direct Connect

If Edge will be connected to a network using static IP addressing or if the Discovery GUI is not installed on the PC, use this method.
Note: The computer must be running Windows 2000 or XP and be configured for DHCP.
1.
Disconnect the computer from the network and directly connect Edge to the computer with an Ethernet cable.
2.
Click Start > Run. Enter ipconfig /renew ↵
3.
Access a web browser and enter 169.254.242.121 into the Address field ↵
OPIN Discovery/Update Application
Use the OPIN Discovery / Update Application on a computer to locate, connect and update Edge.
System Requirements:
Operating Systems:
Find the OPIN Discovery / Update Application at
harddrive.
The Edge must be connected to the network, and power applied, before the device is discovered.
1.
With a computer connected to the same network as Edge, double-click opin-update.jar. The OPIN Discovery / Update Application
opens and the Controller Table populates.
Note: If the Controller Table does not populate, go to Edit > Broadcast Address. The default broadcast address is
255.255.255.255. Some network switches may block this transmission. If this is the case, change the subnet to match the
network, for example 10.7.255.255. Click Save.
2.
Select the desired device from the list.
3.
From Path to Update Package frame, browse to the firmware location on the computer.
4.
Click Install. Firmware is installed.
EH400 - Provides additional functionality to not only Install firmware, but to Changeover, and Rollback firmware updates. Once
firmware is installed, click Changeover to switch to the updated firmware. Click Rollback to switch back to the previoius firmware
version.
5.
View the Status Log for each status while performing Discovery and Update functions.
Configure
The web browser will prompt for login information. From the Login screen enter admin, leaving the Password field empty.
Follow the instructions on the web browser screen to configure Edge.

Hi-O Interface Modules

Hi-O interface modules are used to interface the Edge device (EdgeReader or EdgePlus) with door electronic components. Components
include access control readers, strike, magnetic lock, request to exit, door position switch, and auxillary devices.
For Hi-O interface module wiring, see their prospective Installation Guides.
Go to
www.hidglobal.com
>
Model
Description
EDM-M
EdgeModule Door
EIM-M
EdgeModule Input
EWM-M
EdgeModule Wiegand
EDWM-M
EdgeModule Door & Wiegand
ELM
EdgeModule Lock
EVM
EdgeModule Voltage
4
INSTALLATION GUIDE
Java 6.0 or later. Go to
www.java.com
Windows XP and Fedora 8.
www.ShareMethods.com
Knowledge Center
>
Resources
to download.
> OPIN > Firmware > 2.3.x. Save the files to your local
>
Document
Library. Search the document type as a Installation Guide.
Part Number
82342
82340
82360
82363AM
82301
82365
©2009 HID Global Corporation. All rights reserved.