  • Page 1 Temperature Humidity Meter User’s Manual...
  • Page 2 Sensor Display screen Dew-point Power Wet-bulb Ambient temperature Max-min Data holding Data preserving Data recall Automatic Backlight power-off Unit switch - 1 -...
  • Page 3 Brief Introduction This is a battery meter for measuring relative humidity and temperature. It can display three types of temperatures around the sensor’s air via several convenient procedures: The ambient temperature, the dew-point temperature and the wet bulb temperature. - 2 -...
  • Page 4 Display Screen ⑧ ⑦ ① ⑥ ② ⑤ ③ ④ explanation Low battery Automatic power-off mark Display wet bulb temperature or dew-point temperature Temperature measurement unit Relative humidity measurement unit MEM, RAM position number Max-min Hold function actived.The screen freezes the current reading - 3 -...
  • Page 5: Operation

    Operation notice when moving the meter from one atmosphere with extreme temperature or humidity to another, you need to wait for its stability. Press to start the meter and read the measurements displayed by ° C or ° F. Press to switch DEWPOINT&WETBULB When starting the meter, the ambient temperature...
  • Page 6 Holding Hold the button Press to freeze the current reading, and stop the meter from displaying the measurem ents. When the (HOLD) function is actived,the screen dysplays continue reading the mesured value,press again Max-min Pressing , Max-min is set up, and max updates constantly, press again, it is min.
  • Page 7 The two stations can be switched. If turn off, you need to press for two seconds; a sound shows that this function has been turned off. Max means that the peak of temperature and humidity, while min is the lowest reading. Saving and transferring the measurements This meter is able to save 99 groups reading for transferring.
  • Page 8 five seconds and “00”is displayed at the screen’s right upper corner, which means RAM is cleared. Automatic power-off To prolong the life-span of the battery, this meter offers an automatic power-off function, and it closes without operation in 30 minutes. This function is approved.
  • Page 9 Maintenance Replace the batteries The meter is charged with four 1.5(AAA type) batteries. When appears, the batteries should be replaced as soon as possible. Follow the instructions: 1. unscrew the top of the entrance. 2. Get the batteries out. 3. Install four unused AAA batteries...
  • Page 10 Specification Ambient temperature Range: -20 to 60° C (-4 to 140° F) ± 0.5° C (0 to 45° C) Precision: ± 1.0° C(-20 to 0° C,45 to 60° C) Resolution: ° ° Update rate: 400ms sensor’s type: High-Precision digital sensor (SHT75)...
  • Page 11 Resolution: 0.1° C/° F Update rate: 400ms Range: -50 to 60° C (-58 to 140° F) ± 0.5° C (0 to 45° C) precision : ± 1.0° C(-50 to 0° C,45 to 60° C) Resolution: 0.1° C/° F Update rate: 400ms RAM: 99 data point Power: 4 AAA batteries Weight/size: 190g (batteries included)