Congratulations CONTENTS – You are the owner of a MONITIR Series Thermal Imager. Introduction Quick Start Guide Mechanical Installation Important Network Information & Parameters Camera web server CorDEX MONITIR software MODBUS & HTML IP Addressing Factory Reset CE Declaration of Conformity...
Page 3
REGISTER OVERVIEW YOUR The CorDEX Instruments, MN4xxx series The CorDEX MN4xxx may be installed in a of continuous monitoring cameras offer an standalone or multi camera mode, with each PRODUCT. affordable and accurate means of continuously camera incorporating a built in web server for...
MONITIR Series Thermal Imaging Cameras – User Manual QUICK START GUIDE MECHANICAL INSTALLATION MN4000 Install the camera. The CorDEX MN4000 panel mounted thermal IMPORTANT NOTICE, MN4100 imager is intended for permanent installation CAMERAS ARE SHIPPED WITH A into electrical panels. Installation is achieved Download the CorDEX MONITIR PC Application from PREFIXED STATIC IP ADDRESS OF in two stages.
Page 5
MONITIR Series Thermal Imaging Cameras – User Manual Installation of MN4000 Chassis Remove the MN4000 from its packaging and place on Separate the Camera Package from the Chassis by Using the drill bit specified on the template (xxx), drill Connect 11-30VDC to the green power connector a flat surface, taking care not to scratch the lens.
Page 6
MONITIR Series Thermal Imaging Cameras – User Manual MN4100 If communications are to be used, connect an Ethernet cable with RJ45 plug to Chassis. The CorDEX MN4100 industrial automation thermal imager is intended for permanent installation into fixed locations for industrial automation, control and safety monitoring purposes.
Page 7
MONITIR Series Thermal Imaging Cameras – User Manual Installation of MN4100 This installation procedure assumes that A typical industrial installation will comprise mechanical mounting and positioning has of armoured cable for both power and Remove rear weather cap from camera to expose already occurred, for specific mounting communications, terminating in a junction box Ethernet socket and power terminals.
Page 8
MONITIR Series Thermal Imaging Cameras – User Manual NETWORK INFORMATION AND PARAMETERS IMPORTANT NOTICE Connect camera to a PC running CorDEX MONITIR software, select Direct Connection, Ethernet and use the default address 192.168.1.100. You can now CorDEX MN4000 cameras are shipped as DHCP enabled as setup configuration is via the configure the camera for your network, for more USB port located on the front of the camera.
MONITIR Series Thermal Imaging Cameras – User Manual CAMERA WEB SERVER INTERFACE EACH CORDEX MN4XXX CAMERA IS SUPPLIED WITH AN ONBOARD WEB INTERFACE. Accessing the web interface Home tab Selecting the correct Image Type To access the web interface, open your The Home tab is the default tab after logging The camera captures both visual and thermal internet browser and in the address bar type...
Page 10
MONITIR Series Thermal Imaging Cameras – User Manual Setting Rising/Falling Isotherms Toggling the onboard LED illuminator Thermal only An Isotherm is an alarm condition where a The camera is equipped with an onboard LED The thermal image captured by the 80x60 infrared camera.
MONITIR Series Thermal Imaging Cameras – User Manual Alarm Tab Setting a grid alarm Settings CorDEX MONITIR Software The Alarm tab opens the grid alarm page of To set a grid alarm, click the grid square of The Settings tab allows users to configure The CorDEX MN4xxx series cameras are the MN4xxx webserver.
Page 12
MONITIR Series Thermal Imaging Cameras – User Manual Homepage Network Discovery To deploy Network Discovery from the homepage, ensure the PC running MONITIR Network Direct Connect Direct Connect Settings The CorDEX MONITIR PC Application is Network Discover is intended to identify is connected to the same network as the Discovery (USB)
Page 13
MONITIR Series Thermal Imaging Cameras – User Manual Direct Connect (USB) Then click the Direct Connect (USB) icon Direct Connect (Ethernet) If this is a first time setup of an MN4000, type from the home screen and the Application 192.168.1.100 into the Ip address box and click MN4000 Cameras can be configured via the Both MN4000 and MN4100 have the capability will communicate directly with the camera,...
MONITIR Series Thermal Imaging Cameras – User Manual MODBUS & HTML Register Access: Code 4 Register Access: code 3, 6, 16 HTML Browser The MN4000 and MN4100 have Modbus TCP and HTML access for mage display and The MN4xxx cameras implement Modbus The MN4xxx cameras implement Modbus TCP A web browser may be used to setup analysis.
Page 15
MONITIR Series Thermal Imaging Cameras – User Manual Setting HTML Access (Settings page) An example implementation is as follows: The setting page information is accessed Reading HTTP GET /eth.ccgi?&t=1234&cfk=0&loc= using a HTTP GET. cordex&dhcp=1ðIpAddress=1234ð HTTP GET /lep.bin returns a binary file. In the SubnetMask=1234ðGateway=1234 The webserver is not capable of Server Side javascript this is converted to an unsigned 16...
Page 16
MONITIR Series Thermal Imaging Cameras – User Manual typedef struct lepton_info_struct enum Palette { GREY_POSITIVE=0, GREY_ HTML Access (IR data structure) NEGATIVE, IRON, HOTMETAL, RAINBOW, AMBER, The structure for the IR information: SEPIA }; __packed uint16_t bin_max; typedef struct lepton_settings_struct __packed uint16_t bin_min;...
MONITIR Series Thermal Imaging Cameras – User Manual Ip Address Discovery (Auto-Find IP) Camera Identification (Host Name) Window Coordinate Conversions IP Addressing For user co-ordinates, the top LHS is The units use the network DHCP server to An auto-find is implemented using UDP IP Address Allocation considered to be location (x=0, y=0) assign IP addresses.
Page 18
MONITIR Series Thermal Imaging Cameras – User Manual Auto-Find Example // MonitIRfinder note the changed offsets InitializeComponent(); within ServerResponseData The example has a button and a list box as ServerVer = ServerResponseData[25]. using System; private void button1_Click(object sender, follows: EventArgs e) ToString();...
MONITIR Series Thermal Imaging Cameras – User Manual PB[15:14} PB[15:14} = HWVersion [1:0] defines unit ID HWVersion[1:0] 00 = MN4100 (no LCD) 01= MN4000 (with LCD) Factory Reset MN4100 has a Factory Reset function which erases all user configured settings/data and returns the unit to it original factory setup.
Page 20
REGISTER NOTES YOUR PRODUCT. Register your product now at http://www.cord-ex.com/ register-your-product/ and receive a 12 month extended warranty. Terms & Conditions apply. RUGGED AUTHORITY www.cord-ex.com RUGGED AUTHORITY...