    Catalogue 1. Remarks about Safety 2. Working Principle 2.1 AC Normal 2.2 AC Failure 2.3 Battery and Charging 3. Main Features 3.1 Unattended Operation 3.2 Protection 3.3 Interface Port 3.4 Alarm System 3.5 Phase Locking 3.6 Self-set Frequency 4. Specifications 5.
  • Page 3: Remarks About Safety

    1. Remarks about Safety (In order to keep safe in using the UPS, please comply with the following:) Place with inflammable gas or corrosive gas or much dust Place with very high temperature or very low temperature(above 42 or below Please charge the battery at least 12 hours before the UPS is in operation.
  • Page 4: Ac Normal

    2.2 AC Failure When AC fails, the battery will supply power to the inverter and then passes filter and Short-circuit Protection when UPS is in inverter mode and there is shock or provide power for the equipment, ensuring the continuous power supply. short-circuit, UPS will output limited currency, protecting the UPS( When in AC mode, the UPS will be protected first by input fuse and then transfers to the inverter Filter...
  • Page 5: Protection

    4 Specifications Inverting indicator(red) AC fails or AC abnormal; 500VA 600VA 700VA 800VA 1000VA 1500VA switch. MODEL 350VA /525VA /650VA /750VA /850VA /1200VA /1600VA 7AH 2 8AH 2 Battery 4AH 1 7AH 1...
  • Page 6: Outside Ups

    5.3 Outside UPS on indicator(green) Charging indicator(yellow) Inverting indicator(red) AC Supply to PC UPS Switch Terminal of ground line,input and output AC Battery port connecting to outside line Fuse CAUTION Place for battery PASSED PASSED OUTPUT FUSE INPUT Name Power Battery inside DC voltage CP150...
  • Page 7: Maintenance

    7.2 Battery Maintenance The UPS contains sealed lead-acid maintenance-free battery. The bad environment, the high discharge frequency, the high temperature, etc will dramatically reduce the use life of battery. The use life of battery will also reduce even it is not used. It is suggested to discharge the battery once every 3 months when AC is normal.
  • Page 8: Packing List

    Phenomenon Trouble Shooting Check whether the battery isn't charged charge enough Battery fails to supply power. Check whether the UPS is not turned on correctly UPS doesn't turn to AC(the input Check whether the fuse is broken? plug of the UPS has been plugged The fuse is placed on the UPS back panel.