Intended Application; Approvals; Specifications; Installation - Rheem RXID-AW90A Installation Manual

Whole house dehumidifier with fresh air ventilation
Table of Contents

Advertisement

1. Intended Application for Dehumidifier
The dehumidifier is intended for use in residential
applications to reduce the indoor humidity levels
and increase comfort. With the optional ventilation
ducting and ventilation control hookup, the device
also provides precise amounts of ventilation air.

2. Approvals

The dehumidifier is certified by ETL to meet UL 474
and CSA 22.2 No. 92.

3. Specifications

Model: RXID-AW9A
Electrical: 110-120 VAC, 6.3 Amps,
Capacity: 97 Pints/Day (80ºF [27ºC],
Blower: 240 CFM @ 0.0 in. WG
Coverage (sq ft): Up to 2800
Inlet air temperature range: 55°F min., 100°F max.
Operating Exterior Temp: 56-130ºF (13-54ºC) ducted
Air Flow: 200 CFM without external
Discharge Air Temp: 105ºF (41ºC) (80ºF [27ºC],
Refrigerant Charge: 1 lb., 12 oz. R22
Duct Connections: 6 in. Round Inlet
Filter Size: Pleated MERV 11:
Filter Efficiency: Standard MERV-11 (65%
Unit Size: 34.5"L (w/o Duct Collars) ;
60 Hz, grounded
60% RH)
114 Pints/Day (90ºF
[32ºC], 60% RH)
130 Pints/Day (100ºF
[38ºC], 60% RH)
220 CFM @ 0.4 in. WG
56-100ºF (13-38ºC)
unducted
ducting
60% RH intake)
10 in. Round Inlet
10 in. Round Outlet
14" x 14" x 1"
ASHRAE Dust Spot)
40.5"L (w/ Duct Collars)
x 15.75"W x 20.875"H
(See Fig. 1)
For HVAC Installer Only • Installation Guide
Unit Weight: 92 lbs
Shipping Size: 42"L x 25.875"H x 20.5"W
Weight: 99 lbs
Power Cord: 7.5 ft, 115V With Ground
Drain Connection: 3/4 in. Threaded MPT
INLET VIEW
6
(152)
10
(254)
OUTLET VIEW
15-3/4 (400)
10
(254)
20-7/8
Figure 1: Dimensions.

4. Installation

4.1 Installation Checklist

ImPORTANT: Prior to installation of the
dehumidifier, the following checklist should
be reviewed.
The dehumidifier can be installed in a variety of
locations to meet the owner's needs, and integrate
with existing forced air systems or existing ductwork
if desired. Choose a location with consideration
to accessibility for service, drain availability, and
power outlet location.

4.1A Power Accessibility

Unit should be located in an area where the cord's
length (10') should easily reach a 115 VAC electrical
outlet with a minimum of a 15 A circuit capacity.

4.1B Accessibility

The installed dehumidifier should have at least 14
inches of clearance in the front of the device to
service the filter.
3
SIDE VIEW
34-1/2 (876)
43-1/2 (1092)
(530)
M28622
69-2298—01