VISIO BW-903 RGBW User Manual

Building wash

Advertisement

Quick Links

BW-903 RGBW
User Manual
Please read the instructions carefully before use

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BW-903 RGBW and is the answer not in the manual?

Questions and answers

Summary of Contents for VISIO BW-903 RGBW

  • Page 1 BW-903 RGBW User Manual Please read the instructions carefully before use...
  • Page 2: Table Of Contents

    CONTENTS 1. Safety Instruction ...................... 2 2.Techical Specfications ....................3 3. How To Set The Fixture .................... 5 3.1 Control Panel ..................... 5 3.2 Main Functions ....................6 4. How To Control The Unit..................12 4.1 DMX Controller....................12 4.3 DMX 512 Configuration ................. 14 5.
  • Page 3: Safety Instruction

    1. Safety Instruction Please read the instructions carefully which includes important information about the installation, operation and maintenance. WARNING Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet. Caution: All fixtures are intact from the manufacturer, please operate follow up the user manual, artificial fault are not under guarantee repair.
  • Page 4: Techical Specfications

    2.Techical Specfications - New member of Visio architectural lightings, specially designed to replacing the traditional outdoor 400W discharge fixtures. - Great heat ventilation and heavy duty design to ensure reliable performance under harsh environment - It features 90pcs×3W CREE LEDs provides powerful output...
  • Page 5 Key Facts: Die-cast housing and thermal control for the reliable performance 9000 Lumen Output 1KHz refreshing frequency, flicker-free under HD camera Special design of ventilation system, BW-903 RGBW running full duty cycle Input Voltage: AC 100-240V 50/60Hz Power Consumption:267W Light Source: 90×3W CREE RGBW LEDs...
  • Page 6: How To Set The Fixture

    3. How To Set The Fixture 3.1 Control Panel 1. Display: To show the various menus and the selected functions Button: 2. MENU To select the programming functions 3. DOWN To go backward in the selected functions To go forward in the selected functions 4.
  • Page 7: Main Functions

    3.2 Main Functions To select any functions, press the MENU button until the required one is shown on the display. Select the function by the ENTER button and the display will blink. Use the DOWN and UP button to change the mode. Once the required mode has been selected, press the ENTER button to setup or it will automatically return to the main functions without any change after idling one minute.
  • Page 9 DMX 512 Address Setting Select the , press the ENTER button and the display will blink. Use the DOWN and UP button to change the DMX 512 address. Once the address has been selected, press the ENTER button to setup or automatically exit menu mode without any change after one minute. Back to the previous functions without any change press the MENU button.
  • Page 10 Program Shows Press the MENU button up to when the is shown on the display. Press the ENTER button and select the mode, Press the ENTER button and the display will blink. Use (Show 18)or the DOWN and UP button to select the (Show 17) , (Show 19).
  • Page 11 Display Inversion Press the MENU button up to when the is showing on the display. Press the ENTER (normal) button and the display will blink. Use the DOWN and UP button to select the (inversion) ,Once the mode has been selected, press the ENTER button to setup or automatically return to the main functions without any change after one minute.
  • Page 12 the previous functions without any change press the MENU button。 (flash mode) is selected, press the ENTER button to confirm, then use the DOWN 2. If and UP button to adjust the type of the rotation(1…..9). Once select, press the ENTER button to store or automatically return to the main functions without any change after one minute.
  • Page 13: How To Control The Unit

    Temperature Test Press the MENU button up to when the is blinking on the display. Press the ENTER button and the display will show the temperature of the unit. To go back to the functions press the MENU button again. Fixture Hours Press the MENU button up to when the is blinking on the display.
  • Page 14 press the MENU button again. Please refer to the following diagram to address your DMX512 channel for the first 4 units:...
  • Page 15: Dmx 512 Configuration

    4.3 DMX 512 Configuration 4/5/7 Channels Mode:...
  • Page 16: Dmx512 Connections

    5. DMX512 Connections 1. If you using a controller with 5 pins DMX output, you need to use a 5 to 3 pin adapter-cable. 2. Connect the unit together in a `daisy chain` by XLR plug from the output of the unit to the input of the next unit.
  • Page 17: Troubleshooting

    3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+) 5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), Pin 4/Pin 5: Not used. 6. Troubleshooting Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting: Problem Possible Cause...
  • Page 18: Fixture Cleaning

    7. Fixture Cleaning The cleaning of outside glass must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture’s optics. Clean with soft cloth using normal glass cleaning fluid.
  • Page 19 Declaration of Conformity We declare that our products (lighting equipments) comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility (EMC) Directive 89/336/EEC. EN55103-1: 2009 ; EN55103-2: 2009; EN62471: 2008; EN61000-3-2: 2006 + A1:2009 + A2:2009; EN61000-3-3: 2008. &...