How To Connect Inputs

BNC16-Cable
MYPRPB-Cable
MRGB-Cable

Composite Inputs

Composite inputs are connected to the BNC-16 splitter cable which is attached
to the 26 Way D Conector on the Mosaic-HQ card.
The Luma part of a S-Video input is connected to the leads numbered 1-8 on
the BNC16-Cable and the chroma part is connected to the leads numbered 9-
16.
For example:
For the first composite input the Luma would be connected to lead number 1
and the chroma would be connected to the lead numbered 9. For the second
composite input The luma would be connected to the lead numbered 2 and the
chroma connected to the lead numbered 10 and so on up to a maximum of 8
composite inputs.
If you are using a single Mosaic-HQ, the input numbers specified in the software
correspond to the labels on the splitter cable. (1-8)
If you have connected more than one Mosaic-HQ, connect inputs 1-8 to the
Mosaic-HQ closest to the graphics card. Connect inputs 9-16 to the next
Mosaic card and so on.
Mosaic-HQ card provides the 75ohm termination for each input. The links
should be fitted to apply termination. (All links are fitted as standard.)