Specifications - Tool; Hydraulic Power Source - Greenlee LHFS-210001 Operation, Service And Parts Instruction Manual

Orchard and shade tree pruner
Table of Contents

Advertisement

Specifications - Tool

Length - LHFS-210001 .................................................................................. 42 in.
Weight - LHFS-210001 ............................................................................... 6.9 lbs.
Width ................................................................................................................ 6 in.
Cutting Capacity ......................................................................................... 1-3/4 in.
Type of Hydraulic System .................................................................. Open Center
Pressure Port .......................................................................................... 3/8 NPTF
Return Tank Port ..................................................................................... 3/8 NPTF
Specifications - Hydraulic Power Source
• Power source flow must not exceed 6 gpm (23 lpm).
• Limit relief pressure to 2000 psi (13,790 kPa).
Failure to observe these warnings could result over-pressurizing the system. Severe injury or death may result.
Any hydraulic power source used with this tool must meet the following requirements:
Type of Hydraulic System .................................................................. Open-Center
Flow - Minimum ...........................................................................4 gpm (15.1 l/m)
- Recommended .................................................................5 gpm (18.9 l/m)
- Maximum .............................................................................6 gpm (23 l/m)
Operating Pressure - Minimum ............................................1000 psi (6,895 kPa)
Pressure Relief Setting ...................................................... 2000 psi (13,790 kPa)
Filtration ................................................................................ 10 Micron (Nominal)
Back Pressure - *Maximum ...................................................200 psi (1,379 kPa)
* 200 psi (1,379 kPa) is the maximum agreed standard for the Hydraulic Tool Manufacturers Association (HTMA).
Greenlee Fairmont tools will operate satisfactorily at this standard.
1. Maximum fluid temperature must not exceed 140˚F (60˚C) at the maximum expected ambient temperature.
A sufficient oil cooling capacity is needed to limit the fluid temperature.
2. Maximum flow must not exceed 6 gpm. Install a flow meter in the return line to test the rate of flow in the system
before working the tool.
3. Pressure relief valve must not exceed 2000 psi. The pressure relief valve must be located in the supply circuit
between pump and tool to limit excessive hydraulic pressure to the tool.
4. Figure 2 shows a typical power source being used with the tool.
Greenlee Textron / Subsidiary of Textron Inc.
- LHFS-210002 .................................................................................. 48 in.
- LHFS-210003 .................................................................................. 60 in.
- LHFS-210005 .................................................................................. 78 in.
- LHFS-210002 ............................................................................... 7.1 lbs.
- LHFS-210003 ............................................................................... 7.7 lbs.
- LHFS-210005 ............................................................................... 7.9 lbs.
- Maximum .........................................2000 psi (13,790 kPa)
Orchard and Shade Tree Pruner
6
4455 Boeing Dr., Rockford, IL 61109-2988 815/397-7070

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lhfs-210002Lhfs-210003Lhfs-210005

Table of Contents