Download Print this page

LG 32PC50 Service Manual page 12

Hide thumbs Also See for 32PC50:

Advertisement

Color Coordinate
Mode
x
COOL
0.276±0.003
MEDIUM
0.283±0.003
WARM
0.313±0.003
* Refer to the below case to know what value is fixed.
* CASE
- First adjust the coordinate much away from the target
value(x, y).
1) x, y > target
(1) Decrease the R, G.
2) x, y < target
(1) First decrease the B gain.
(2) Decrease the one of the others.
- In case of decreasing the x, decreasing the R : fix G
- In case of decreasing the y , decreasing the G : fix R
3) x > target , y < target
(1) First decrease B, so make y a little more than the
target.
(2) Adjust x value by decreasing the R.
4) x < target , y > target
(1) First decrease B, so make x a little more than the
target.
(2) Adjust x value by decreasing the G.
(7) When adjustment is completed, Exit adjustment mode
using EXIT key on R/C.
10. Default Value in Adjustment mode
(Default values maybe modified the module condition)
10-1. White Balance
<Default Value on OSD>
11. Internal press test
Item
Dielectric Voltage (AC <-> FG)
Dielectric Voltage (Without FG)
12. Sound spec.
Item
Audio Practical Max Output, L(Mono)/R
Copyright©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Temp
y
0.283±0.003
11,000K
0.295±0.003
9,300K
0.329±0.003
6,500K
Value
Unit
Remark
1.5
kV
At 100mA for 1sec (Line)
1.5
At 100mA for 1min (OQC)
3
kV
At 100mA for 1sec (Line)
3
At 100mA for 1min (OQC)
Min
Typ
Max
Unit
9
10
12
W
Each PCB assembly must be checked by check JIG set.
uv
(Because power PCB Assembly damages to PDP Module,
especially be careful)
0.000
13. POWER PCB Assy Voltage
0.000
Adjustments
0.003
13-1. Profile
: To supply the Va, Vs voltage that the module want.
13-2. Required Test Equipment
(1) Stick for adjustment.
(2) DMM.
13-3. Connection Diagram for Measuring
: refer to (Fig. 1)
13-4. Adjustment Method
(1) Va Adjustment
1) After receiving 100% Full White Pattern, HEAT RUN.
2) Connect + terminal of D. M..M. to Va pin of P812, connect
-terminal to GND pin of P812.
3) After turning VR901,voltage of D.M.M adjustment as
same as Va voltage which on label of panel right/top.
(deviation; ± 0.5V)
(2) Vs Adjustment
1) Connect + terminal of D. M..M. to Vs pin of P812, connect
-terminal to GND pin of P812.
2) After turning VR851, voltage of D.M.M adjustment as
same as Vs voltage which on label of panel right/top.
(deviation ; ± 0.5V)
(Fig. 1) Connection Diagram of power adjustment for measuring.
14. Input the Shipping Option Data
(1) Push the ADJ key in a Adjust Remote control.
(2) Input the Option Number that was specified in the BOM,
into the Shipping area.
(3) The work is finished, Push
Remark
- 12 -
(Va, Vs Voltage adjustments)
A
Key.
LGE Internal Use Only