Summary of Contents for Inova Labs Inc. Duo2

  • Page 1 Follow Us @InovaLifeChoice Manufactured for & Distributed by 3500 Comsouth Drive, Suite 100, Austin, Texas 78744 USA Corporate Office 1.512.617.1700 | www.InovaLabs.com © 2015 Inova Labs Inc. All rights reserved. 13M-001 Rev H April 2015...
  • Page 2 Operator’s Manual Manufactured for & Distributed by www.InovaLabs.com...
  • Page 3 Copyright © 2015 Inova Labs, Inc. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission from Inova Labs Inc. Inova Labs Inc.
  • Page 4: Table Of Contents

    TABLE OF CONTENTS Introduction Application/Indications For Use Symbol Descriptions Warnings Contraindications Adverse Events/Hazards System Overview Compatibility Interoperability Standard Package Contents User Controls Part Names Operating Instructions Light Indicators/Alarms Routine Maintenance Specifications Oxygen Concentration Over Altitude and Flow Rate Accessories Technical Support Disposal Service Life Service Life Record...
  • Page 5: Introduction

    APPLICATION/INDICATIONS FOR USE This manual applies to the Activox DUO2 Stationary Base Model 130-001. INDICATIONS FOR USE: The Activox DUO2 Oxygen Concentrator is used on a prescriptive basis by adult patients who are diagnosed as requiring supplemental oxygen.
  • Page 6: Symbol Descriptions

    SYMBOL DESCRIPTIONS Symbol Description Symbol Description Symbol Description Portable Oxygen Consult Instructions Caution Concentrator for Use Connection No Smoking No Oil or Grease No Open Flame Do Not Disassemble Keep Dry This Side Up Fragile, Handle Compliant with Class II Equipment with Care WEEE Temperature Limit...
  • Page 7: Warnings

    It is not recommended to operate the device near or adjacent to other equipment other than the LifeChoice Activox POC. If adjacent use is necessary, the Activox DUO2 Stationary Concentrator should be observed to verify normal operation in the configuration in which it will be used.
  • Page 8: Adverse Events/Hazards

    ADVERSE EVENTS/HAZARDS Failure to adhere to the statements below may impair performance of the device and may void all warranties. 1. DO NOT use oil, grease or petroleum-based products on or near the device. 2. DO NOT use power supplies or air filters other than those that came with the system.
  • Page 9: System Overview

    SYSTEM OVERVIEW The Activox DUO2 System is a fully-integrated oxygen concentrator system for stationary and portable use. It consists of the Activox DUO2 Stationary Base and the LifeChoice Activox POC. It is important to keep the POC connected to the stationary base when not in use.
  • Page 10: Standard Package Contents

    STANDARD PACKAGE CONTENTS Replacement Air Filter Activox DUO2 Stationary Base* LifeChoice Activox POC* LifeChoice Activox External Battery (Standard Package) (Sold Separately) AC Power Cord External Battery Crate (On back of unit) Tool Holder Maintenance Tool *Model identified on unit and packaging labels.
  • Page 11: User Controls

    USER CONTROLS Activox DUO2 Stationary Base Control Panel Power External Battery Alarm Reset Indicator Charge Indicator Indicator Button Power Flow Setting Switch Control Dial Flow Setting Meter Power Switch: Turns the stationary base on or off. Reset Button: If the internal circuit breaker has been tripped, the...
  • Page 12 LifeChoice Activox POC Control Panel When a LifeChoice Activox POC and Activox DUO2 Stationary Base are connected, the POC’s Control Panel will provide additional control functions for the stationary base. For instructions on using the POC separately, please refer to the LifeChoice Activox Portable Oxygen Concentrator Operator’s Manual that came as a part of the system.
  • Page 13: Part Names

    PART NAMES Retractable Handle LifeChoice POC Connection Activox POC Cable Cradle Cannula Nozzle Lifting Handles Fitting (on both sides) Locking Front Wheels POC Connection Cable: The Connection Cable plugs into the port on the left side of the POC. Lifting Handles: The handles are used when manually lifting the stationary base.
  • Page 14 PART NAMES continued Air Filter External Battery Access Door Charging Port External Battery Crate Fan Inlet Vent AC Power Cord Strap AC Power Cord Rear Wheels Fan Outlet Vent (bottom) Air Filter Access Door: The door is used to access the Air Filter for replacement.
  • Page 15: Operating Instructions

    OPERATING INSTRUCTIONS The Activox DUO2 Stationary Base is designed to be used with a compatible LifeChoice Activox POC. It is important to keep the POC connected to the stationary base when not in use. The POC offers additional control functions for the stationary unit, as well as monitors overall system operation and records service-related incidents.
  • Page 16 CAUTION: Only use external batteries approved by Inova Labs. NOTE: The External Battery will begin charging after the Internal Battery in the POC has reached a 100% charge. The External Battery will also charge when the POC is not connected to the DUO2.
  • Page 17 OPERATING INSTRUCTIONS continued OPERATING YOUR SYSTEM: 1. Flip the Power Switch to the “On” position. A one second audible beep will sound, the Power LED will illuminate green and the system will begin running. It takes approximately two minutes to reach full oxygen concentration.
  • Page 18: Light Indicators/Alarms

    Charging Internal POC. base. Connected to Activox DUO2 4L Model: “Connected to Activox DUO2”, the INT Battery Bar and the External Power Symbol will display on the screen. “Charging Internal” will display until the Internal Battery is fully charged.
  • Page 19 ALARM/LIGHT INDICATORS continued NORMAL OPERATION INDICATORS Normal Light Indication Audible Action Operation Alarm Stationary None. The stationary base base is on and None is properly connected to connected to Power the POC. the POC. LED illuminates solid green. Battery Charge LED may illuminate or flash if External Battery is connected.
  • Page 20 When the POC is connected to the Stationary Base, the POC mute button can be pressed to mute the audible tones from the Stationary Base. NOTE: The unit will not alarm for low oxygen purity during the first five minutes of Activox DUO2 operation to allow the unit to reach full oxygen production.
  • Page 21: Routine Maintenance

    ROUTINE MAINTENANCE The Activox DUO2 System was designed to minimize the amount of routine maintenance that is required. The device includes no end- user repairable parts. Aside from the preventative maintenance outlined below, all other required maintenance must be performed by qualified personnel.
  • Page 22 ROUTINE MAINTENANCE continued 5. Replace with a new Air Filter. A. Put the new Air Filter into its housing. B. Firmly push down on the Air Filter until it pops securely into place. 6. Replace the Air Filter Access Door. 7.
  • Page 23: Specifications

    SPECIFICATIONS These specifications apply to the Activox DUO2 Stationary Base. For LifeChoice Activox POC specifications, refer to the LifeChoice Activox Portable Oxygen Concentrator Operator’s Manual. Device Electrical Classification: Class II, Type B Stationary Base Weight: 37.5 lbs. (17 kg) Dimensions: 14.2” w x 24.8” h x 14.6” d (36 cm w x 63 cm h x 37cm d)
  • Page 24: Oxygen Concentration Over Altitude And Flow Rate

    NOTE: Stated accuracy of multi-function oxygen concentrator indicator is +/- 2%. ACCESSORIES (ADDITIONAL/REPLACEMENT/SPARE) The accessories listed below are for the Activox DUO2 Stationary Base. Please refer to the LifeChoice Activox Portable Oxygen Concentrator Operator’s Manual for a list of accessories applicable to that unit.
  • Page 25: Technical Support

    Customer Care Team Monday-Friday, 7:00AM-7:00PM CST at 1.512.617.1744. DISPOSAL Inova Labs expects end users to dispose of the Activox DUO2 system in an environmentally friendly way. Electrical and electronic equipment is labeled with a crossed-out wheeled bin symbol indicating that the equipment should be disposed of by the end user separate from other types of waste.
  • Page 26: Service Life Record

    SERVICE LIFE RECORD In the event that a component of the Activox DUO2 System is returned for service or repair, use this section to track the date and details of service. Components Serviced Date Unit Serviced Date (Sieve Bed, Serviced...
  • Page 27 Components Serviced Date Unit Serviced Date (Sieve Bed, Serviced (Stationary or POC) Returned Compressor, etc.)
  • Page 28: Warranty

    (1) year for th POC and three (3) years for the DUO2 from the Date of Purchase. Accessories and Batteries are warranted to Purchaser solely to be free of defects, for one (1) year from the Date of Purchase for Accessories and Batteries.
  • Page 29 WARRANTY continued The Limited Warranty extends only to the Purchaser and is not transferable unless otherwise expressly agreed to in writing by Inova Labs. Inova Labs’ oxygen concentrators produce enriched oxygen gas which accelerates combustion. DO NOT ALLOW SMOKING OR OPEN FLAMES within ten (10) feet (three (3) meters) of these devices while in use.
  • Page 30 WARRANTY continued shipping container must clearly display the RMA number which properly identifies returned Items and the Item must be packaged together with proof of Date of Purchase. Items returned without a proper RMA number shall be refused and returned to Purchaser at Purchaser’s expense. All returned Items are subject to warranty confirmation by Inova Labs.
  • Page 31 WARRANTY continued STRICT LIABILITY OR OTHERWISE. PURCHASER AGREES AND ACKNOWLEDGES THAT THE ITEMS ARE OF A SIZE, DESIGN AND CAPACITY SELECTED BY ITS MEDICAL PROVIDER. Basis of Bargain PURCHASER ACCEPTS THESE DISCLAIMERS OF WARRANTIES AND LIMITATIONS OF LIABILITY CONTAINED HEREIN AS PART OF A BARGAIN WITH RESPECT TO THE PRICING OF THE ITEMS AND UNDERSTANDS THAT THE PRICING WOULD LIKELY BE HIGHER IF INOVA LABS WERE REQUIRED TO BEAR LIABILITY IN EXCESS OF...
  • Page 32: Emc Information

    Guidance and Manufacturer’s Declaration - Electromagnetic Immunity and Emissions The Activox DUO2™ Stationary Base is intended for use in the electromagnetic environment specified below. The customer or end user of the model 130- 001 should assure that it is used in such an environment.
  • Page 33 INFORMATION continued Immunity Test IEC 60601 Compliance Electromagnetic Test Level Level Environment - Guidance Portable and mobile RF communications equipment should be used no closer to any part of the model REF 130-002, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.
  • Page 34 Voltage Fluctuations/Flicker purposes. Emissions, IEC 61000-3-3 Recommended Separation Distances Between Portable and Mobile RF Communications Equipment and The Activox DUO2 Stationary Base Model 130-001. The model 130-001 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user...
  • Page 35: Provider Instructions

    PROVIDER INSTRUCTIONS BATTERY CHARGING Connection of the Activox POC to the DUO2 Stationary Base (No External Battery) 4L -When the POC is connected to the stationary base, it will generate a short audible beep tone. The POC display will read “Charging Internal”...
  • Page 36 “Mute” icon. To un-mute, press the POC “Mute” button again. Pro & Sport - When the Stationary DUO2 produces an alarm, depress the POC “Mute” button and the audible tone will be muted. The RED “Alarm” LED on the stationary base will remain on. The amber LED next to the “Mute”...