MF 8,12,16,24 PROFESSIONAL POWER AMPLIFIERS MF SERIES OWNERS MANUAL ALTAiR EQUIPOS EUROPEOS ELECTRÓNICOS, S.A.L. AVDA. DE LA INDUSTRIA, 50. 28760 TRES CANTOS (MADRID) 91-8043265 91-8044358 altair@altairaudio.com. www.altairaudio.com...
ALTAiR PROFESSIONAL POWER AMPLIFIERS MF SERIES CONTENTS 1. INTRODUCTION 2. SWITCHES, INDICATORS, ATTENUATORS AND CONNECTORS. MF8 AND MF12 FRONT PANEL MF16 AND MF24 FRONT PANEL MF8 AND MF12 REAR PANEL MF16 AND MF24 REAR PANEL 3. WORKING PRECAUTIONS 4. INSTALLATION...
MF series. There is a lot the characteristics that make of the ALTAIR power amplifiers MF series, one of the most highlighted of the audio professional market, here enumerated some:...
Page 4
ALTAiR PROFESSIONAL POWER AMPLIFIERS MF SERIES For this purpose, all the MF series power amplifiers has a “soft-clipping” circuit that acts on the output power by comparing the input and output signals. Once it detects a distortion or other noticeable cut, it stabilizes the integrity of the output signal thereby avoiding overloading and saturation levels that might damage the system.
ALTAiR PROFESSIONAL POWER AMPLIFIERS MF SERIES 2. SWITCHES, INDICATORS, ATTENUATORS AND CONNECTORS. These are the switches, indicators, attenuators and connectors that you could find in your power amplifier. The description and explanation of each one of them, you will find it in the corresponding section.
ALTAiR PROFESSIONAL POWER AMPLIFIERS MF SERIES MF8 AND MF12 REAR PANEL COOLING VENTS MF16 AND MF24 REAR PANEL OUTPUT POWER SPEAKON CONNECTOR. ® BINDING POST. FAN (ONLY MF16 AND MF24). FUSE HOLDER. MAINS CORD. EARTH LINK SWITCH. INPUT SIGNAL CONNECTOR XLR-3-31.
ALTAiR PROFESSIONAL POWER AMPLIFIERS MF SERIES JACK 1/ 4" INPUT SIGNAL LINK CONNECTOR. (ONLY MF8 AND MF12). XLR-3-32 INPUT SIGNAL LINK CONNECTOR. (ONLY MF16 AND MF24). MONO/ STEREO/ BRIDGE SWITCH. 3. WORKING PRECAUTIONS The manufacturer cannot be held responsible for any damage which is incurred by not using the power amplifier in compliance with the warranty or working precautions.
ALTAiR PROFESSIONAL POWER AMPLIFIERS MF SERIES Due to the weight of the unit, it should be securely fastened at the front and the back of the cabinet. If the racks are carriage ones, it is advisable that have trays in order to allow the power amplifier to rest on its base and in an elastic cradle, if possible.
ALTAiR PROFESSIONAL POWER AMPLIFIERS MF SERIES In the connection of several devices to the same AC distribution board and extension cables, keeps in mind the maximum current of the power amplifier, and make sure that the mains connector, as well as the AC distribution board, are of enough current capacity, since could take place in the mains connector, and in the same AC distribution board a overheat- ing, with the risk of fire and/or short circuit.
ALTAiR PROFESSIONAL POWER AMPLIFIERS MF SERIES UNBALANCED INPUT: This type of connection will be used when the sound source doesn't provide balanced output. If it is possible, will be employed the connection type 1. 1) Using twin-lead shielded cable: POWER...
ALTAiR PROFESSIONAL POWER AMPLIFIERS MF SERIES OUTPUT POWER CONNECTION. MODES OF OPERATION Each channel includes a pair of five-way binding post and a SPEAKON connector. ® These connectors are wired inside in parallel. The red binding post is positive and the black is ground.
ALTAiR PROFESSIONAL POWER AMPLIFIERS MF SERIES The possible output connections, depends on the configuration of the switch MONO/ STEREO/ BRIDGE of the power amplifier: CAUTION: Do not change the configuration of MONO/STEREO/BRIDGE switch unless the power amplifier is first turned off. Before turn on the power amplifier, make sure that the mains, input and output connections are correct.
ALTAiR PROFESSIONAL POWER AMPLIFIERS MF SERIES * LOUDSPEAKERS WIRED TO BINDING POST * THE LOUDSPEAKERS CONNECTION COULD CHANNEL 2. CHANNEL 1. BE ACHIEVE TO THE BINDING POST OR TO THE SPEAKON CONNECTOR, SINCE THESE ® CONNECTORS ARE WIRED INTERNALLY IN PARALLEL.
ALTAiR PROFESSIONAL POWER AMPLIFIERS MF SERIES EARTH LINK In some installations, it might be necessary to isolate the power amplifier electric ground, from the system mains earth, in order to avoid ground loops, that could generate unwanted noises, for this reason, the power amplifier provides an EARTH-LINK switch placed at the rear panel in order to lift the mains earth from the power amplifier electric ground.
ALTAiR PROFESSIONAL POWER AMPLIFIERS MF SERIES INPUT ATTENUATORS Each power amplifier channel has a input signal attenuator, gauged. The calibration is measured between ±0.5 dBu. The input attenuators are independent for each channel in STEREO mode. In the models MF16 and MF24 in mode MONO it is selectable the control...
ALTAiR PROFESSIONAL POWER AMPLIFIERS MF SERIES ERROR INDICATORS The power amplifier load protection circuit, work when a continuous voltage appears in the power amplifier output connectors, shorcutting the power amplifier output, disconnecting the input signal (the ON/STBY LED of the corresponding channel illuminates on...
ALTAiR PROFESSIONAL POWER AMPLIFIERS MF SERIES Therefore, whenever this indicator is in red, will indicate us that the power amplifier input signal is disconnected, and the power amplifier is not operative at that moment. This occurs when the power amplifier is turned on, and when the ERROR or THERMAL protections are activated.
ALTAiR PROFESSIONAL POWER AMPLIFIERS MF SERIES If you want that your power amplifier works with 2 Ω load impedances, you should consult the speaker impedance curves that is going to connect and study each case in particular. It is very advisable enable the power amplifier limiter, whenever it is working with 2Ω...
ALTAiR PROFESSIONAL POWER AMPLIFIERS MF SERIES AMPLIFIER CONDITIONS AMPLIFIER CONDITION INDICATORS The power amplifier has just been turned on (it is still in the initial mute delay) and it is receiving an input signal. In this case the ON/STBY indicators of both channels would be illuminated in red.
Page 20
ALTAiR PROFESSIONAL POWER AMPLIFIERS MF SERIES INDICATORS AMPLIFIER CONDITION The DC protection of one channel has been activated. In this case, the ERROR indicator (red) and the ON/STBY indi- cator (red) of the channel in which the protection has been activated will be illuminated.
In the models MF8 and MF12 the XLR polarity and the input sensibility configurations takes place on the power amplifier input board (INPUT MF8/12 ALTAIR- 072) shown in the next figure. This board is located in the upper left corner of the rear panel (as you face the front...
The limiter configuration in the models MF8 and MF12 takes place in the driver board (DRIVER MF8/12 ALTAIR- 074). Part of this board is showed in the next figure. This badge is located parallel to the power amplifier bottom plate. The driver board is wide, occupying almost the whole width of the power amplifier.
ALTAiR PROFESSIONAL POWER AMPLIFIERS MF SERIES CONFIGURATION PIN 1 - GROUND. (A.E.S.) PIN 2 - POSITIVE. PIN 3 - NEGATIVE. PIN 1 - GROUND. PIN 2 - NEGATIVE. PIN 3 - POSITIVE. INPUT ATTENUATOR CONFIGURATION IN MODE MONO (MF16 AND MF24 ONLY) The input attenuators (potentiometer), may be configurated in MONO mode for the models MF16 and MF24.
ALTAiR PROFESSIONAL POWER AMPLIFIERS MF SERIES NOTE: Remember that in the models MF8 and MF12, this limiter configuration takes place in the driver board. INPUT SENSIBILITY/GAIN ADJUST The power amplifier input sensibility may be configurated with two jumpers, one for each channel.
ALTAiR PROFESSIONAL POWER AMPLIFIERS MF SERIES The different resistors in order to get input sensibilities between 0 dBu and +8dBu are shown in the next table: INPUT SENSIBILITY RESISTOR (1%) +1 dBu (0,87 V). 39K2 +2 dBu (0,98 V). 16K9 +3 dBu (1,10 V).
ALTAiR PROFESSIONAL POWER AMPLIFIERS MF SERIES 9. GRAPHS MF24: Typical common mode relation ratio (C.M.R.R.) MF24: Frequency response at rated output into 4Ω. versus frequency. MF24: Total harmonic distortion versus output power, MF24: Total harmonic distortion versus frequency at into 4 Ω. at 1 KHz.
ALTAiR PROFESSIONAL POWER AMPLIFIERS MF SERIES 10. WARRANTY This unit is warranted by Equipos Europeos Electrónicos to the original user against flaws in the manufacturing and in the materials for a length of time of one year, starting from the date of sale.
Need help?
Do you have a question about the MF8 SERIES and is the answer not in the manual?
Questions and answers