4.1.

eSD Self Check

1. Select [ 3 ] eSD self check.
Operation specifications
Indication contents
• eSD self check result display
Display the eSD self check result information.
Displays other than "OK" are abnormalities of eSD.
Push the menu button to end the service mode, and then POWER OFF.
4.2.

Lock Search History Indication

1. Select [ 4 ] Lock search history indication.
Operation specifications
Indication contents
• Lock search history indication
Display the camera system error code for three histories saved in EEPROM.
• The error code contents which are displayed
Lock search history indication is finished by POWER OFF.
Error code
51
Focus control is abnormal
52
Zoom control is abnormal
53
OIS lens control is abnormal
73
High temperature is abnormal
33
Communication between camera to ARM is abnormal