EUROSTER 1100Z – USER MANUAL
Euroster 1100Z is a processor-based electronic temperature controller designed to control
DHW and heating water circulating pumps. It operates with two sensors and according to two
independent temperature settings.
When incorporated in hydronic heating systems supplied by coal or gas-fired boiler it controls
forced circulation of heating water.
The function of EUROSTER 1100Z is to maintain the temperature of water at a constant level
on the hot water cylinder or on the DHW circuit.
The unit features cylinder cooling protection - to avoid excessive drop of temperature on the
hot water cylinder, following the decrease of heating boiler temperature and DHW priority
option.
EUROSTER 1100Z is equipped with ANTISTOP system, to prevent seizure of pump
rotor in idle periods. Throughout the non-heating season every fortnight the integral
processor of EUROSTER 1100Z will automatically cycle the pump for 30 seconds. For this
function to be operational, the thermostatic controller must NOT be switched off at the end of
the heating season.
1. Status indication – DHW mode
2. Status indication – heating mode
3. DHW/ heating mode switch, temperature adjustment – up
4. DHW/ heating mode switch, temperature adjustment – down
5. On/off switch for continuous pump operation (on DHW/ heating circuits)
6. On/off mains switch
7. Power supply to DHW pump, 230 V AC
8. Temperature sensor on DHW circuit
9. Temperature sensor on heating circuit
10. Power supply to heating water circulating pump, 230 V AC
11. Power supply to controller unit, 230 V AC

1. INSTALLATION

DANGER! Dangerous voltage is present both inside the enclosure and on the
outgoing cables. Prior to installation by a qualified electrician make sure that
the unit has been disconnected from power supply to avoid the risk of electric
shock. Units with mechanical damage should not be installed.
EUROSTER 1100Z
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1100Z and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EUROSTER 1100Z

  • Page 1 When incorporated in hydronic heating systems supplied by coal or gas-fired boiler it controls forced circulation of heating water. The function of EUROSTER 1100Z is to maintain the temperature of water at a constant level on the hot water cylinder or on the DHW circuit.
  • Page 2 EUROSTER 1100Z – USER MANUAL a. mounting of the controller: • the controller is fixed directly to the wall or to any other support with two screws (plastic plugs c/w screws are part of delivery) • the cables extending from the controller are fixed to the wall with cable clips b.
  • Page 3 EUROSTER 1100Z – USER MANUAL d. DHW priority • for switching the DHW priority on/off simultaneously press the two switches under the display until the right outermost dot on the LED display changes its status. The DHW priority is on when the light comes up, and off - when the light is off.
  • Page 4 (DHW/ heating), temperature setpoint and the current temperature, as measured by the sensor. 4. COMPLIANCE WITH STANDARDS AND CONFORMITY CERTIFICATES EUROSTER 1100Z is in compliance with the following EU directives: EMC, LVD The CE certificate of conformity is posted on our website: www.euroster.com.pl 5.
  • Page 5 7. WIRING DIAGRAMS These are simplified diagrams and as such they not show all the components necessary for fully functional operation of the system. wiring of EUROSTER 1100Z in a system with a stand-alone hot water cylinder Heating boiler Hot water cylinder...

Table of Contents