Do not remove the cover plate from the inside of the
appliance.
Remove the activated charcoal filter from the metal grease
3.
filter.
Clean the metal grease filter and the filter cover.
4.
After removing the filters, clean the inside of the appliance.
5.
Replacing or regenerating the activated charcoal filters
Activated charcoal filters trap the odour-causing compounds in
cooking smells. They are only used for circulating-air mode.
Notes
The activated charcoal filters are included with the appliance.
When the activated charcoal filters need to be replaced, they
can be obtained from specialist retailers, from our after-sales
service or from our online shop.
Only use genuine Bosch filters. This will ensure that the
appliance performs optimally.
Refer to the printed supplement for information about the
regenerability of the activated charcoal filters.
Remove the holder on the rear of the metal grease filter and
1.
take out the activated charcoal filter.
Clean the appliance.
2.
Clean the metal grease filters.
3.
Secure the new activated charcoal filter using the holder on
4.
the rear of the metal grease filter.
8
Cleaning the metal mesh grease filters
Notes
Do not use any aggressive, acidic or alkaline cleaning
agents.
When cleaning the metal mesh grease filters, also clean the
holder for the metal mesh grease filters in the appliance
using a damp cloth.
The metal mesh grease filters can be cleaned in the
dishwasher or by hand.
By hand:
Note: You can use a special grease solvent for stubborn dirt. It
can be ordered via the Online Shop.
Soak the metal mesh grease filters in a hot soapy solution.
Clean the filters with a brush and then rinse them thoroughly.
Leave the metal mesh grease filters to drain.
In the dishwasher:
Note: If the metal mesh grease filters are cleaned in the
dishwasher, slight discolouration may occur. This has no effect
on the function of the metal mesh grease filters.
Do not clean heavily soiled metal mesh grease filters together
with utensils.
Place the metal mesh grease filters loosely in the dishwasher.
The metal mesh grease filters must not be wedged in.
Installing the metal mesh grease filter
Insert metal grease filter.
1.
Fold the metal grease filter up and click it into place.
2.
Fold the filter cover upwards.
3.
Note: Make sure that the filter cover closes properly.
Resetting the saturation displays
Once you have cleaned or replaced the relevant filters, reset
the saturation indicator to stop the symbols from flashing.
Make sure that the extractor hood and the lighting have been
switched off.
Press and hold the
button until F flashes three times.
#
This resets the saturation indicators.