6. Output contact: Indication of Loudspeaker Line measurement
The output contact is activated when the amplifier
performs line surveillance.
(1) Name. Enter a name to identify the contact.
(2) Standby Status. Defines the standby status of
the contact.
NO: Contact normally open;
NC: Contact normally closed.

6.2.4. Configuration of the Temperature Control tab

Through this tab the temperatures at which the cooling fans of the power unit are activated and
deactivated can be configured.
(1) Front Fan.
Activation and
deactivation
temperatures of
the front fan of
the amplifiers
UP-367ETH and
UP-247ETH.
(2) Rear Fan.
Activation and
deactivation
temperatures of
the rear fan of
the amplifiers
UP-367ETH, UP-
247ETH and UP-
127ETH.
(3) Alarm
Temperature -
ON. When the set
temperature is
reached, the unit
generates an
alarm via IP and
the FAIL relay is
activated.
(4) Alarm
Temperature -
OFF. When the
set temperature is reached, the unit stops sending the temperature alarm via IP and deactivates the FAIL
relay.
(5) Average factor for Frontal Sensor. There are two temperature sensors on the amplifier, one at
the front and another at the back. The temperature of the amplifier is obtained from the weighted
average of these sensors. This value indicates the weighting of the front sensor with respect to the rear
sensor.
UP-x7ETH version 1.1
UP-67ETH, UP-127ETH,
UP-247ETH, UP-367ETH
(1)
(1)
(2)
(2)
(3)
(3)
(4)
(4)
(5)
(5)
Digital power unit
(1)
(2)
34

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Up-127ethUp-247ethUp-367eth

Table of Contents