Optimus DVA-102ETH Operating Manual
Optimus DVA-102ETH Operating Manual

Optimus DVA-102ETH Operating Manual

Digital voice announcer and optimax system gateway
Table of Contents

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DVA-102ETH and is the answer not in the manual?

Questions and answers

Summary of Contents for Optimus DVA-102ETH

  • Page 3: Table Of Contents

    10.2.11. ACTIVATE OR DEACTIVATE THE MONITOR LOUDSPEAKER ..........29 11. TYPICAL CONFIGURATIONS WITH DVA-102ETH .................. 30 11.1. DIGITAL AUDIO TO DIGITAL POWER UNITS (UP-ETH) ..............30 11.2. DVA-102ETH AND ANALOG ZONES THROUGH A UMX-02/0 AUDIO MATRIX ........31 DVA-102ETH version 1.2 R&D Department...
  • Page 4 Digital voice announcer DVA-102ETH and Optimax system gateway 11.3. DVA-102ETH AND ANALOG ZONES ACTIVATED BY CONTACT ............34 11.4. DVA-102ETH AND ANALOG ZONES ACTIVATED BY CONTACT, WITH LOUDSPEAKER LINE SURVEILLANCE ..........................37 12. NETWORK SPECIFICATIONS ........................ 39 13. STECHNICAL SPECIFICATIONS ......................41 14.
  • Page 5: Introduction

    OPTIMUS DVA-102ETH unit Ethernet- Another functionality of the DVA-102ETH is that it controlled player of digital messages in WAV or OGG works autonomously, as a source of messages towards format. analog power units or as a link between an installation...
  • Page 6: Front View

    LINK. When lit, it indicates the connection of the Ethernet B input with the HUB or SWITCH. (3) Download connector Used to update the firmware of the DVA-102ETH. (12) Ethernet A input status indicators These serve the same purpose as the ETHERNET B...
  • Page 7: Rear View

    Ethernet connection is detected or an (2) Power supply input internal communication error occurs. To power the DVA-102ETH, connect a power supply of 24 V DC / 2 A to this input. (15) IP ADDRESS DIP switches...
  • Page 8: Configuration Of The Rs485 Address

    Digital voice announcer DVA-102ETH and Optimax system gateway 4. CONFIGURATION OF THE RS485 ADDRESS Table I On an RS485 BUS, each unit must have a different address. Table I shows configuration RS485 ADDRESS switches their possible values. DVA-102ETH version 1.2 R&D Department...
  • Page 9: Configuration Of The Ip Address Of The Unit

    II on the next page shows all the DIP switch combinations When the unit starts to run, the dipswitches IP address is from 0 to 255. automatically saved in the DVA-102ETH flash memory. To change the address, it is necessary to delete first the IP 3. Switch on the unit.
  • Page 10 Digital voice announcer DVA-102ETH and Optimax system gateway TABLE II DVA-102ETH version 1.2 R&D Department...
  • Page 11: Configuration Of The Ip Of The Unit By Software

    P.A. Manager software. To make the change by software, right click with the mouse on the name of the DVA-102ETH on the message panel and select the option Web Connection (1).
  • Page 12: Internal Configurations

    PHANTOM power supply of the DIPSWITCH 1= OFF AUDIO INPUT DISABLED (factory configuration) Dipswitch PHANTOM power supply of the DIPSWITCH 2= ON EMERGENCY INPUT ENABLED (factory configuration) PHANTOM power supply of the DIPSWITCH 2= OFF EMERGENCY INPUT DISABLED DVA-102ETH version 1.2 R&D Department...
  • Page 13: Equipment Connections

    When the internal jumper JP3 is removed (see section 0), the shield of the Cat 5 FTP cable is separated from the ground connection of the signal circuit. In certain installations, this makes possible eliminate alternating noises caused by ground loops. Figure 6 DVA-102ETH version 1.2 R&D Department...
  • Page 14: Emergency Input Connection

    Pin 6: Priority contact of the live voice emergency message. connector. It is connected to pin 6 of the AUDIO OUTPUT (priority output) connector Although the DVA-102ETH may not through the internal jumper J6 (see section 0). be powered, the signal applied to Pin 8: GND.
  • Page 15: Audio Output Connection

    INPUT is activated, the signal applied to the AUDIO INPUT will be sent to this zone. Figure 10. Example of input contacts connection for activation of pre- recorded messages from the DVA-102ETH. Figure 11 7.6. OUTPUT CONTACTS CONNECTION The unit has 19 output contacts, which can be configured by means of the P.A.
  • Page 16: Rs485 Bus Connection

    Optimax system gateway 7.7. RS485 BUS CONNECTION One of the DVA-102ETH functions is that it can act as a link between an installation in an OPTIMAX network and analog PA systems with UMX-02/0 or UDCE-01 zones and analog power units.
  • Page 17: Configuration By Software

    Optimax system gateway 8. CONFIGURATION BY SOFTWARE For the unit implementation in the installation, it is necessary to have a PC connected to the DVA-102ETH, either through the ETHERNET network, or through a crossed network cable. The PC must have the P.A. Manager software installed.
  • Page 18 102ETH is connected to another equipment unit by POLLING CSMA protocol according means of the RS485 bus. units If there is more than one DVA-102ETH connected to the DVA-102ETH • • connected RS485 bus, only one of them will have the RS485 Gateway DALA-01/0B •...
  • Page 19 Confirm the change by clicking on Yes. Close the multicast configuration window by clicking on OK. ATTENTION: The values that are modified from the multicast configuration window affect all the equipment units in the multicast group in the installation. DVA-102ETH version 1.2 R&D Department...
  • Page 20 The recommended order of priority depending on the model is as follows: UP-xETH CC-100ETH DVA-102ETH SU-114N UP-xETH UMX-ETH > > > > > UMX-CC DC-600ETH COU-02/0ETH SU-214/0N (Backup amplifier) (program UMX-ETH FC-600ETH or priority) (Control) DVA-102ETH version 1.2 R&D Department...
  • Page 21: Configuration Of Parameters

    Configures the language in which the messages appear on the LCD screen of the DVA-102ETH. (2) Buzzer (NOT IMPLEMENTED) The DVA-102ETH has a buzzer which is activated when an alarm is received. This control activates or deactivates the buzzer. (10)
  • Page 22: Configuration Of Contacts

    Pulse and Level. If pulse is configured, a pulse is required to activate the Once the parameters accessed via the three tabs of the DVA-102ETH (General – Parameters - Contacts) have been configured, click on the button Accept in the lower part of the window.
  • Page 23: Creation Of Dva-102Eth Analog Zones

    DVA-102ETH and Optimax system gateway 8.3.1. CREATION OF DVA-102ETH ANALOG ZONES On the DVA-102ETH, an analog zone is an analog amplifier that receives audio from the AUDIO OUTPUT and whose priority is activated by an output contact of the DVA-102ETH.
  • Page 24: Assigning The Dva-102Eth To A Server Pc

    Optimax system gateway 8.5. ASSIGNING THE DVA-102ETH TO A SERVER PC In installations with a Server PC, in order to be able to send DVA-102ETH messages from the P.A. Manager, it is necessary to associate the DVA-102ETH with the Server PC.
  • Page 25: Pre-Recorded Messages

    There are two different ways of recording files in the Compact Flash memory of the DVA-102ETH. A. Recording onto the memory by means of a Compact Flash card reader. 1. Remove the memory from the DVA-102ETH and position it in a Compact Flash memory card reader connected to the PC that contains the files.
  • Page 26 If the message is one of the Common Messages, click on the and select the message. In Common Messages this case, the parameters of this message will be changed on all the DVA-102ETH units in the installation. 4. Activate the option Change settings (4).
  • Page 27: Operations From The Front Controls

    Starts or activates the level menu option selected Monitor messages of the DVA-102ETH Modify program and priority volumes of Moves the user to Enters the menu shown the DVA-102ETH the higher level on the screen menu.
  • Page 28: Operations From The Dva-102Eth Menu

    Press OK. 10.2.5. VIEW THE SYSTEM ALARMS NB: The message monitored is only played through the monitor loudspeaker of the DVA-102ETH. It is not sent From the start screen, press . to any zone in the installation. Press  until you see the option ALARM LIST on the screen.
  • Page 29: Modify The Eth Priority Volume

    DVA- 8. Press OK. 102ETH via IP. This volume affects the audio of the AUDIO OUT output 1. From the start screen, press . of the DVA-102ETH when this plays a message from 2. Press until option ...
  • Page 30: Typical Configurations With Dva-102Eth

    Digital voice announcer DVA-102ETH and Optimax system gateway 11. TYPICAL CONFIGURATIONS WITH DVA-102ETH 11.1. DIGITAL AUDIO TO DIGITAL POWER UNITS (UP-ETH) DESCRIPTION The DVA-102ETH, the PC, the DC-600ETH desk digital power units (ETH series) are connected to the Ethernet network.
  • Page 31: Dva-102Eth And Analog Zones Through A Umx-02/0 Audio Matrix

    102ETH (in the diagram, contacts 3, 4 and 5), an analog microphone with zone selection (MD-94R6) can be used. When a zone is selected from the MD-94R6 desk, the DVA-102ETH sends the zone selection commands via RS485 to the UMX-02/0, which activates the output corresponding to the zone selected.
  • Page 32 Establish the RS485 input address (this UMX-2E to which address must the audio output of coincide with the the DVA-102ETH is value of the RS485 connected as the configuration associated input. switch on the back The audio input of of the DVA-102ETH)
  • Page 33: Dva-102Eth Version 1.2 R&D Department

    Assign a zone to the contact. The input contact will be activated when the message is started from the MD-94R6 desk. Through the RS485 bus, the DVA-102ETH will send the order to the UMX-02/0 so that it activates the output of UMX-2S card corresponding to that zone.
  • Page 34: Dva-102Eth And Analog Zones Activated By Contact

    Digital voice announcer DVA-102ETH and Optimax system gateway 11.3. DVA-102ETH AND ANALOG ZONES ACTIVATED BY CONTACT DESCRIPTION The PC, the DVA-102ETH and the DC- 600ETH desk are connected to the Ethernet network. Three output contacts of the DVA- 102ETH (contacts 1, 2 and 3) are configured to activate the priority of the analog power units.
  • Page 35 Digital voice announcer DVA-102ETH and Optimax system gateway INSTALLATION STRUCTURE CONFIGURATION Add the analog zones to the DVA-102ETH. Configure them, assigning a contact to each one. Once the analog zones have been configured, when the Contacts configuration DVA- 102ETH is opened, the output contacts already appear in the list of configured contacts.
  • Page 36 Assign a zone to the contact. When a zone is selected from the MD-94R6 desk, one of these input contacts activated, and when message is started, the DVA- 102ETH will activate output contact corresponding to the zone selected. DVA-102ETH version 1.2 R&D Department...
  • Page 37: Dva-102Eth And Analog Zones Activated By Contact, With Loudspeaker Line

    Surveillance of the status of the loudspeaker lines by the DALA-01/0B. The status of the lines is sent through the RS485 connection to the DVA-102ETH, and this sends the data via Ethernet to the PC and DC-600ETH. RS485 communication between DALA-01/0B and DVA-102ETH supports CSMA or POLLING protocol.
  • Page 38 (DALA-01-CSMA or of the installation DALA-01-POLLING). (in this case, with the DALA-01). The configuration of the Contacts tab of the DVA-102ETH must be identical to the configuration in section 11.3. DVA-102ETH version 1.2 R&D Department...
  • Page 39: Network Specifications

    Bandwidth: 4 Mb for each audio channel. Number of audio channels: Up to 50 global channels (from the exchange to the satellites). Up to 50 local channels (internal to the satellite, they do not consume backbone bandwidth). DVA-102ETH version 1.2 R&D Department...
  • Page 40 Multicast routing (Spanning Tree). Small installations, with a proprietary network: Capacity to handle TOS (Type Of Service). Nortel: BayStack 425 Cisco: 500G and 29600 families Equitel: N950 6. Network protocol stack (*) Multicast addresses and reserved ports DVA-102ETH version 1.2 R&D Department...
  • Page 41: Stechnical Specifications

    Section 5. Unit IP address configuration by means of dipswitches. Recording in Flash. April 11 R&D Department Section 8.2. Configuration of parameters. June 11 Apartado 6. Internal configurations R+D Department Approved by Position Date Ferran Gironès i Puig R&D Director 26/04/2011 DVA-102ETH version 1.2 R&D Department...
  • Page 42: Guarantee

    In the event that the guarantee No guarantee benefits shall be provided other than those cited here. rights do not apply, OPTIMUS S.A. shall duly inform the client. If, within a In order to claim the guarantee rights, it shall be an essential...