Website: www.mhinstek.com 2. Inspecting Package Contents When you get a new VAM7520P Voltage Meter, please inspect the instrument as follows: 2.1 Check if there is damage due to transportation If the package is damaged, please retain them until the instrument and accessories are tested.
VAM7520P Voltage Meter voltage,current,power,charging capacity and time at the same time. It also can set the over voltage protection,over current protection,over power protection, over charging capacity protection,over time protection and low-voltage protection.The voltage meter adopts two groups of LED digital tubes to display the data.
Button LED digital tube Operation Tips 4-1 The introduction of VAM7520P 4.2 Wiring On the back of the meter there are three terminals on the right, they are “IN-”, “+” and “OUT-”, the”+”is the public terminal of “IN +” and “OUT +” , the...
VAM7520P Voltage Meter “Vext” on the left side of the meter, it is used for three-wire system. This meter has two-wire and three-wire dual input methods. Two wire system can connect the meter to the circuit directly, three-wire system requires an external power supply for the instrument.
VAM7520P Voltage Meter 5.1 Wiring Select the appropriate wiring according to the range of the measured voltage, ensuring input voltage is within the tolerance range of the instrument. Note: The input voltage range of two-wire : 10V ~ 75V; The input voltage range of three-wire : 0V ~ 75V.
VAM7520P Voltage Meter Exit debug mode : In the debug mode, you can exit by pressing the < OUT > button for a while. 5.4 The functions of debug mode 5.4.1 "0 - U" is the calibration of the voltage value, the voltage value displays in the digital tube is the current measure value.
Page 9
VAM7520P Voltage Meter 5.4.4 "3 - r" is to restore factory settings, if you want to return to the initial value, you can adjust to "- y -" by pressing , then press< OUT >, it will restore to the factory setting.
VAM7520P Voltage Meter 5.4.11 "10 - L" low-voltage protection (LoP), if you have set the LoP value, when the output voltage is less than the setting voltage , the machine will automatically cut off the output, at the same time, the screen display protection type is "LoP", press any key to return to normal.
Page 11
VAM7520P Voltage Meter thereof will be free from defects in workmanship and materials for a period of one year from the data of purchase. We will repair or replace, at its’ option, defective product or component parts. Returned product must be accompanied by proof of the purchase date.
Need help?
Do you have a question about the VAM7520P and is the answer not in the manual?