Advertisement

Quick Links

Arion 1004
Installation Guide
Revision 1.0
09/04/2002

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Arion 1004 and is the answer not in the manual?

Questions and answers

Summary of Contents for Alpha Telecom Arion 1004

  • Page 1 Arion 1004 Installation Guide Revision 1.0 09/04/2002...
  • Page 3 Arion 1004 Installation Guide Revision 1.0 09/04/2002 Information in this guide is subject to change without notification.
  • Page 4 All brand names and product names are trademarks or registered trademarks of their respective companies / holders. Copyright 2002 Alpha Telecom, Inc. U.S.A. This document may only be distributed, in printed or electronic form, by Alpha Telecom, or by parties authorized by Alpha Telecom.
  • Page 5: Table Of Contents

    Table of Contents Important Safety Instructions Introduction Package Contents Front Panel Rear Panel Wiring Instructions Diagnostics Application Guideline Information Appendix A: Ordering Information Appendix B: Setup Configuration Appendix C: Basic Configurations Appendix D: System Status Appendix E: Line Status Appendix F: H.323 Status Appendix G: RTP/RTCP Status...
  • Page 6 Table 8: Power Supply Information Important Safety Instructions If you experience technical difficulty with the Arion 1004 please contact the distributor or point of sales for help. Never install telephone wiring during a lightning storm. Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.
  • Page 7: Package Contents

    ISDN Telephone set to reach the Next Generation IP Network. Functionally an ISDN Telephone and the Arion 1004 are equivalent to an ISDN Mode VoIP Phone. The Arion 1004 provides the existing, widely deployed ISDN Telephones a smooth and quick way to access the Next Generation Network (NGN).
  • Page 8: Front Panel

    Figure 1 shows the Arion 1004 in perspective view to show all of the LEDs and labels. There are five LEDs in the front panel of the Arion 1004. Each of the first four LEDs from the left indicates the status of the labeled port. The last LED indicates activation of the Arion 1004.
  • Page 9: Wiring Instructions

    Wiring Instructions Figure 3 shows the wiring diagram of the Arion 1004 with one typical setup. equipment in reference are the Arion 1004, Quad NT1, ISDN Telephones, and the LAN Network. Specific step-by-step instructions follow. 10/100Base-T Hub/Switch LAN Network Arion 1004...
  • Page 10: Figure 4: Rear Cable Connectors

    Step 1: Connect the DC power plug of the power supply to the power connector on the rear of the Arion 1004 as shown in Figure 4 Place the power cable into the wire clip to secure it Figure 4. Rear Cable Connectors...
  • Page 11: Diagnostics

    Diagnostics Initial connection to the AC Outlet, the Arion 1004 should have the following LED Status. LEDs Status 1 ~ 4 Solid: Ux (x=1~4) Interf ace is not ready or unable to obtain sync Fast Blinking (8Hz): Ux (x=1~4) is in the process of synchronization...
  • Page 12: Application Guideline Information

    The application shows the Arion 1004 being used in a network environment supporting a Quad NT1 with one ISDN Telephone per S/T-Interface. The Arion 1004 is connected to a 10/100Base-T LAN Hub/Switch via the LAN Connector on the Arion 1004. (NOTE FOR...
  • Page 13 S/T-Interface of the NT1 serving the new location. Upon re-registering with iMerge and new ISDN IP Gateway, check to make sure that one can draw dial tone by going off-hook on the ISDN Telephone set. Arion 1004 Installation Guide...
  • Page 14: Appendix A: Ordering Information

    Appendix A: Ordering Information To order any of the following components, please contact Alpha Telecom, Inc. U.S.A. at (256) 772- 5245 or visit ourwebpage: www.alpha-tele.com. Arion 1004 Complete Kit 555-1004GA Arion 1004 Unit only 553-1004GA Arion 1004 Installation Guide 035010041000...
  • Page 15: Appendix B: Setup Configuration

    Appendix B: Setup Configuration Configuring the Arion 1004 for first time users. 1. Open your Web browser (i.e. Internet Explorer or Netscape Navigator). 2. In the “ Address”field, type http://192.168.0.1 and press the <ENTER> key. ? 192.168.0.1 with DHCP disabled will be the manufacturer default setting 3.
  • Page 16 Restart - Reset and restart the device For Basic Configuration of the unit, click “ Basic Configuration”on the left hand column. The following items will show. Continue with Appendix C Step 1. Arion 1004 Installation Guide...
  • Page 17: Appendix C: Basic Configurations

    All the changes will be saved and be used from now on. RELOAD will reset all parameters on this page, to original values or settings. NOTE: Configurations are marked as red color will only take effect after restart Arion 1004 Installation Guide...
  • Page 18: Appendix D: System Status

    , will display the speed of the Ethernet interface and the current status of the four U-Interfaces (U1, U2, U3, and U4). NOTE: Configurations are marked as red color will only take effect after restart Arion 1004 Installation Guide...
  • Page 19: Appendix E: Line Status

    Appendix E: Line Status Selecting Line Status on the left hand column under System Status , will display the current status of the connection between the device and the iMerge. Arion 1004 Installation Guide...
  • Page 20: Appendix F: H.323 Status

    Appendix F: H.323 Status Selecting H.323 Status on the left hand column under System Status , will display the current status of the Aliases, Local Ports, Remote Ports, Call Reference Values, and Media Channel. Arion 1004 Installation Guide...
  • Page 21: Appendix G: Rtp/Rtcp Status

    Appendix G: RTP/RTCP Status Selecting RTP/RTCP Status on the left hand column under System Status, will display the current status of the RTP and RTCP channels per port. Arion 1004 Installation Guide...
  • Page 22: Appendix H: System Log

    Appendix H: System Log Selecting System Log on the left hand column under System Status, will display the current system log entries. Arion 1004 Installation Guide...
  • Page 23: Appendix I: Advanced Configurations

    , will display a list of advanced selections. These are Administration, Ethernet and TCP/IP, H.323, RTP/RTCP, System Log, and Restore factory settings. NOTE: Configurations are marked as red color will only take effect after restart Arion 1004 Installation Guide...
  • Page 24: Appendix J: Administration

    8. Click “ RESTART”Button to activate the reset/restart unit function. 9. RELOAD will reset all parameters on this page, to original values or settings. NOTE: Configurations are marked as red color will only take effect after restart Arion 1004 Installation Guide...
  • Page 25: Appendix K: Ethernet And Tcp/Ip

    LAN Ethernet connection rate, selection if behind a firewall, the firewall’ s IP Address, and SNTP (Simple Network Time Protocol) IP Address. NOTE: Configurations are marked as red color will only take effect after restart Arion 1004 Installation Guide...
  • Page 26: Appendix L: H.323 Configurations

    Appendix L: H.323 Configurations Selecting H.323 Configurations on the left hand column under Advanced Configurations, will display the port settings for the device. NOTE: Configurations are marked as red color will only take effect after restart Arion 1004 Installation Guide...
  • Page 27: Appendix M: Rtp/Rtcp Configurations

    (iMerge’ s Firewall), the port settings for the device, and selections for Jitter Buffer. NOTE: Configurations are marked as red color will only take effect after restart NOTE: Configurations are marked as red color will only take effect after restart Arion 1004 Installation Guide...
  • Page 28: Appendix N: System Log Configurations

    Selecting System Log Configurations on the left hand column u nder Advanced Configurations, will display selections to Enable/Disable System Trace, selection of modules to trace, which includes: System, Network, DSP, Line, Comm, H.323, RAS, H.225, H.245, RTP, and RTCP. Arion 1004 Installation Guide...
  • Page 29: Appendix O: Restore Factory Settings

    RTP Base Port 1024-65520 6000** Average Jitter Buffer 10-90 50 ms Maximum Jitter Buffer 100 ms 20-160 * Access Gateway H.225 RAS Ports and RTP Ports must not overlap ** RTP Base Port must be an even number Arion 1004 Installation Guide...
  • Page 30: Appendix P: Firmware Upgrade

    Appendix P: Firmware Upgrade Selecting Firmware Upgrade on the left hand column , will display the TFTP Server information. The listing includes: TFTP Server IP Address, TFTP Retry, and TFTP Timeout settings. Arion 1004 Installation Guide...
  • Page 31: Appendix Q: Restart

    Appendix Q: Restart Selecting Restart on the left hand column , will allow you to save changes and restart the device. Arion 1004 Installation Guide...
  • Page 32: Appendix R: Firewall Port Settings

    To configure the Firewall Port settings for RTP/RTCP, select the RTP/RTCP configuration from the Advanced Configurations Web Page. 1. 8 UDP Ports for the bearer calls (RTP/RTCP). a. The default port setting is 6000. Valid port setting range is 6000 to 6015. Arion 1004 Installation Guide...
  • Page 33: Appendix S: Interface Pin Assignments

    Assignments Each interface has specific pinouts which are important for electricians and technicians to know. Anyone installing wiring for the Arion 1004 should pay close attention to this information. All interfaces described here are located on the rear panel of the Arion 1004.
  • Page 34: Appendix T: Cable Pinouts

    Figure 6. RJ45 LAN Pin Locations 12345 6789 Figure 7. DB9 Pin Locations Figure 8. Power Pin Locations Appendix U: Power Supply Pinouts The Arion 1004 is powered by an AC power supply included with the unit. Unit Input Output 16 Watt 120VAC@60Hz +48VDC@250mA Table 8.
  • Page 35: Appendix V: Troubleshooting Tips

    The Arion 1004 is powered on and programmed, the ISDN Phones are configured correctly. iii. Verify the Arion 1004 can be seen on the network by using ping. iv. Access the Web page “ System Status”to check the communications between the Arion 1004 and the Switch.
  • Page 36: Appendix X: Command On Console

    Dhcp Turn on DHCP Dhcp on Turn off DHCP Dhcp off 5. IpAddr Display IP Address Ipaddr Set Static IP Address : Ipaddr xxx.xxx.xxx.xxx 6. Subnet Display Static Subnet : Subnet Set Static Subnet Subnet xxx.xxx.xxx.xxx Arion 1004 Installation Guide...
  • Page 37 Status SysLog [Event | Decode] 9. Submit Save changes and restart : Submit 10.Restore Restore the factory default values : Restore 11.Trace Display trace status Trace Turn on trace Trace on Turn off trace Trace off Arion 1004 Installation Guide...
  • Page 38: Appendix X: Acronyms

    DHCP Dynamic Host Configuration Protocol Hertz GraphicalUser Interface Internet Protocol RTCP Real-time Transport ControlProtocol Real-time Transport Protocol SNTP Simple Network Time Protocol Transmission ControlProtocol Type of Service TFTP Trivial File Transfer Protocol Volts VoltsAC Volts DC Arion 1004 Installation Guide...
  • Page 39: Fcc Notice

    2) This device must accept any interference received, including interference that may cause undesired operation. If your Arion 1004 causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of servicemayberequired. But if advanced notice isn’...
  • Page 40: Notes

    NOTES: Arion 1004 Installation Guide...
  • Page 41: Wall Mounting Template

    Wall Mounting Template 4.73” Arion 1004 Installation Guide...
  • Page 42 INTENTIONALLY LEFT BLANK Arion 1004 Installation Guide...
  • Page 43 P/N: 035010041000...

Table of Contents