Section III. Trouble Shooting
If there is a signaling
problem, the following
methods may remedy it:
Problem: Short operating
distance (20 ft. or less).
Action:
• Change battery
(CR2025, 3V Lithium) in
keychain remote.
Problem: Not operating.
Action:
• When using the keychain
remote, make sure you
are within the expected
operating distance from
the Transceiver.
(Operating distances can
very depending on local
RF noise levels.)
• Verify the House and
Unit codes are set
correctly on the
Transceiver, keychain
remote, and the PG2000.
CAUTION
BEFORE removing PG2000
cover, ALWAYS
DISCONNECT POWER at
main breaker AND at the
PG2000 switches. In order to
verify the codes in the
PG2000, the cover must be
removed.
Pentair Pool Products
1620 Hawkins Ave., Sanford, NC 27330 • (919) 774-4151
10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 523-2400
P/N 840344
0.5A
(Colorwheel Fuse)
PG2000
Chassis GND
PG2000 Neutral
UNIT
HOUSE
9
I
.
.
.
.
7
11
G
K
.
.
.
.
5
13
E
M
.
.
.
.
3
C
O
15
.
.
. .
1
A
"LEFT"
X
PG2000 (Front View) & Wiring Diagram
Figure 4.
SAVE THESE INSTRUCTIONS.