E1/PRI Splitter/Buffer INSTALLATION AND OPERATION Applicable Products E1DT - E1/PRI Splitter / Buffer Part Numbers: E1DT-ASSY-0058 E1DT-ASSY-0059 Document Reference E1DT-MAN-P112, Issue 4 Publication Date 31 October 2010 Published by Somerdata Ltd. 1 Riverside Business Park St Annes Road Bristol BS4 4ED Sales &...
E1/PRI Splitter/Buffer REVISION HISTORY Issue Date Notes Oct 2010 Contact details amended 21 Nov 2008 Updated 13 Feb 2008 Updated 2 Mar 2006 First Published Installation and Operation...
INTRODUCTION 1 4 B S COPE 1 6 B U UIDES PRODUCT DESCRIPTION NTRODUCTION VAILABLE ERSIONS E1DT-ASSY-0058 E1DT-ASSY-0059 POWER CONNECTION OWER OURCE E1DT-ASSY-0058 SIGNAL CONNECTIONS NTRODUCTION NPUT UTPUT ONNECTOR INOUTS E1DT-ASSY-0059 SIGNAL CONNECTIONS NTRODUCTION NPUT UTPUT ONNECTOR INOUTS SPECIFICATIONS NTERFACE...
Page 4
E1/PRI Splitter/Buffer ONITOR UTPUT SOLATION NSERTION UTPUT TO NPUT ARIATION UTPUT ALANCE RROR OISE NO SIGNAL LOADED INPUT ROSSTALK STANDARD INPUT AXIMUM NPUT OLTAGE UTPUT RIVE APABILITY UTPUT RIVE TTENUATION POWERED ERFORMANCE ROSSTALK ESIDUAL OUTPUT NPUT SIGNAL LOADING OWER EQUIREMENTS OLTAGE URRENT ONNECTOR...
Page 5
E1/PRI Splitter/Buffer 6 B W ARRANTY 5 5 B I NTRODUCTION 5 6 B W ARRANTY ERMS AND ONDITIONS 8 B N OTICES 5 5 B G ENERAL NFORMATION ECLARATION OF ONFORMITY OMERDATA AND THE NVIRONMENT 6 9 B I NTRODUCTION 7 0 B C URRENT...
Page 6
E1/PRI Splitter/Buffer This page intentionally blank Installation and Operation...
S cope 1 4 B This User Guide covers SomerData E1DT E1/PRI Splitter/Buffer. U ser Guides 1 6 B Printed copies can be supplied on request. Please contact your local supplier or SomerData for ordering details. Electronic copies (Adobe Acrobat files) are included on the SomerData CD-ROM that is supplied with the original products.
Page 8
E1/PRI Splitter/Buffer This page intentionally blank Installation and Operation...
In this Section NTRODUCTION VAILABLE ERSIONS Introduction E1DT E1 Splitter/Buffer provides a means of monitoring and capturing traffic flowing in both directions of a 2Mbits/s E1/PRI (G.703/G.704) communications link. The line connections are made through two RJ-45 connectors that are hard-wired in parallel.
Available Versions Two versions of E1DT are available. E1DT-ASSY-0058 Provides the monitor outputs on a single RJ-45 connector (Stream A pins 1/2 and 4/5) for use with devices that monitor both Tx and RX on the same input connector. This version is not compatible with SomerData...
100mA power supply with 2.1 mm (centre positive) low voltage connector. An unregulated power supply can be used provided that the input voltage to E1DT does not exceed 12V. UK and European AC power adapters are available as options. +6 Volts DC to +12 Volts DC...
Page 12
E1/PRI Splitter/Buffer This page intentionally blank Installation and Operation...
In this Section NTRODUCTION NPUT UTPUT ONNECTOR INOUTS Introduction Both Tx and Rx monitor outputs are on a single RJ-45 connector (Stream A). E1DT-ASSY-0058 should not be used with a SomerData PC-VDR E1/PRI Recorder R2D3 E1/PRI Data Capture Card (see E1DT-ASSY-0059).
E1/PRI Splitter/Buffer Input/Output Connector Pinouts Line Input/Output Monitor Outputs Stream A – Output +ve Tx direction – Output -ve – Ground – Output +ve RX direction – Output -ve – Not used – Not used – Not used This product approved connection public...
E1/PRI Splitter/Buffer 5. E1DT-ASSY-0059 SIGNAL CONNECTIONS In this Section NTRODUCTION NPUT UTPUT ONNECTOR INOUTS Introduction Tx and Rx monitor outputs are on two RJ-45 connectors. Stream A for the Line Tx bitstream and Steam B for the Line Rx bitstream.
E1/PRI Splitter/Buffer Input/Output Connector Pinouts Line Input/Output Monitor Outputs Stream A Stream B – Output +ve Output +ve – Output -ve Output -ve – Ground Ground – Not used Not used – Not used Not used – Not used Not used –...
E1/PRI Splitter/Buffer Line Interface Signal ITU G.703/G.704, 2,048 kbits/s Line Code HDB3 Data Type Framed or Unframed Signal Amplitude Operating: ±3.00V ±10% nominal Absolute Maximum: -5V (lower limit) +5V (upper limit) Line Connection Two RJ-45 connectors hard-wired in parallel. Optional BNC adapter cable available on request. Line connection supports 120 balanced, 75 unbalanced...
E1/PRI Splitter/Buffer Buffer Monitor Outputs (Stream A and Stream B) E1DT-ASSY-0058 RJ-45 connector (Tx pins 1/2 and Rx pins 4/5) E1DT-ASSY-0059 Two RJ-45 connectors (Tx pins 1/2) compatible with SomerData R2D3 E1/PRI Data Capture card Input Impedance 1500 Monitor Output Impedance...
Page 21
E1/PRI Splitter/Buffer Output Drive Capability Greater than 50 metres (120 load, Cat 5 cable) Output Drive Attenuation 0.2dB per 10 metres Un-powered Performance Crosstalk Better than -64dB Residual output Better than -35dB Input signal loading Less than 0.1dB Power Requirements Voltage Operating: +6 Volts DC to +12 Volts DC...
Page 22
E1/PRI Splitter/Buffer Environmental Temperature 0°C to 70°C Relative Humidity 5% to 95% non-condensing Physical Dimensions 55mm x 45mm x 25mm (ABS enclosure) Weight 50gms Installation and Operation...
Page 23
E1/PRI Splitter/Buffer S UPPORT I n this Section 6 7 B 4 7 B W HAT TO DO IF YOU HAVE A PROBLEM 4 8 B S ERVICING AINTENANCE AND EPAIRS 4 9 B I F YOU NEED UPPORT 5 0 B S OMER ONTACT NFORMATION...
Page 24
E1/PRI Splitter/Buffer I f you need Support 4 9 B For warranty, technical and application support issues, you should initially contact your supplier to check whether your SomerData product is covered by warranty, extended warranty or maintenance contract. At SomerData, we will make our best efforts to provide prompt and friendly support by phone, fax and e-mail.
Page 25
We will be able to deal with your request more efficiently if you provide the following details (where available) in your Fault Report: Part Number or Model Number (for example E1DT-ASSY-0059) Serial Number (for example 2008/19/926) Software Version (for example 2.0) Details of any symptoms or error messages...
Page 26
E1/PRI Splitter/Buffer R eturns 5 2 B Please do not return any products to SomerData without first contacting SomerData and obtaining a Return Merchandise Authorisation (RMA) Number. This will ensure that the processing of any repair or upgrade is handled efficiently and in accordance with any agreed action. If the SomerData product is under warranty, repairs are free-of charge.
Page 27
E1/PRI Splitter/Buffer E nd-of-Life Disposal 5 3 B Your SomerData product may be returned to SomerData at the end of its life at the customer's expense under the EU proposed regulations on waste from electrical and electronic equipment legislation, provided that the product is free from radiation or biological contaminants and that no other legislation forbids the return.
Page 28
E1/PRI Splitter/Buffer This page intentionally blank Installation and Operation...
E1/PRI Splitter/Buffer W ARRANTY I n this Section 6 8 B 5 5 B I NTRODUCTION 5 6 B W ARRANTY ERMS AND ONDITIONS I ntroduction 5 5 B This section describes SomerData’s Warranty Terms and Conditions. Where the SomerData product has been supplied via an authorised Reseller, the Warranty and Support is between SomerData and its Reseller.
Page 30
E1/PRI Splitter/Buffer W arranty: Terms and Conditions 5 6 B SomerData warrants all goods supplied by it to be free from defects in material and workmanship, under normal use, care, storage and service, for a maximum period of twelve months from the date of delivery (per Incoterms 2000) by SomerData.
E1/PRI Splitter/Buffer N OTICES I n this Section 6 8 B 5 5 B G ENERAL NFORMATION ECLARATION OF ONFORMITY OMERDATA AND THE NVIRONMENT 6 9 B I NTRODUCTION 7 0 B C URRENT OMPLIANCE CTIVITIES 7 1 B R ESTRICTION OF USE OF AZARDOUS UBSTANCES...
1 Riverside Business Park Bristol BS4 4ED United Kingdom Equipment description: E1 Data Splitter/Buffer Model: E1DT-ASSY-0058 E1DT-ASSY-0059 Conforms to the following Product Specifications: Safety: IEC 950 EMC: 89/336/EEC EN55022 Harmonised Standard The product complies with the requirements of the Electromagnetic Compatibility Directive 89/336/EEC as amended and the Low Voltage Directive 73/23/EEC and carries the CE marking accordingly.
E1/PRI Splitter/Buffer Somerdata and the Environment I ntroduction 6 9 B SomerData is committed to design and introduce products that conform to applicable environmental legislation and standards. One of our missions is to integrate environmental stewardship into the business of providing quality products, services, and customer support at the best value.
Page 34
E1/PRI Splitter/Buffer R estriction of use of Hazardous Substances (RoHS) 7 1 B Somerdata has also established a RoHS qualification process to help ensure that products meet stringent reliability and quality requirements, as well as regulatory compliance requirements. The maximum allowable hazardous substance at a homogeneous material level under the EU RoHS Directive is shown in the following table.
Available Versions ................2-2 Contact Details ..................7-2 Customer Support ................7-1 Declaration of Conformity ..............9-2 E1DT-ASSY-0058 ................2-2 E1DT-ASSY-0058 Signal Connections ..........4-1 Input/Output Connector Pinouts ............4-2 Introduction ..................4-1 E1DT-ASSY-0059 ................2-2 E1DT-ASSY-0059 Signal Connections ..........5-1 Input/Output Connector Pinouts ............
Page 36
E1/PRI Splitter/Buffer SomerData and the Environment ............9-3 Specifications ..................6-1 Buffer ....................6-4 Environmental ................... 6-6 Line Interface ..................6-3 Physical .................... 6-6 Power Requirements ................ 6-5 Un-powered Performance..............6-5 Support End of life disposal ................7-5 Returns ..................... 7-4 Support Requests ................