2.3.5. Field Power Status LED ........................11 Dimension ..................................12 3.1. NA-9286 ..............................12 Mechanical Setup ..............................13 4.1. Total Expansion ............................13 4.2. Plugging and Removal of the Components................13 Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL : www.crevis.co.kr...
Page 4
EtherCAT Mailbox ........................... 23 6.4. CoE Interface – parameter management in the EtherCAT system ........26 6.5. EtherCAT Reference ..........................27 APPENDIX A ..................................28 A.1. Product List................................28 A.2. Glossary ..................................30 Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL : www.crevis.co.kr...
Avoid touching conductive components, e.g. FnBUS Pin. 1.1.3. Certification (TBD) c-UL-us UL Listed Industrial Control Equipment, certified for U.S. and Canada See UL File E235505 CE Certificate EN 61000-6-2:2005 EN 61000-6-4/A11:2011 RoHS (EU, China) Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL : www.crevis.co.kr...
Test time : 1hrs for each test EMC resistance burst/ESD EN 61000-6-2 : 2005, EN 61000-6-4/A11 : 2011 Installation Pos. / Protect. Class Variable/IP20 Product Certifications UL, cUL, CE, FCC, KCC, RoHS(EU,China) Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL : www.crevis.co.kr...
- 1 Green, Field Power Status 2 LEDs (each RJ-45 Connector) - 1 Yellow Link, Active - 1 Green Not used Module Location Starter module – left side of FnIO system Field Power Detection About 11Vdc Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL : www.crevis.co.kr...
- Mismatch vendor code between adapter and expansion module. 2.3.5. Field Power Status LED State LED is : To indicate : Not Supplied Field Not supplied 24V dc field power Power Supplied Field Power Green Supplied 24V dc field power Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL : www.crevis.co.kr...
To do so, fold on the upper of the locking lever. To pull out the FnIO module, unfold the locking lever as below figure. Before work is done on the components, the voltage supply must be turned off. Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL : www.crevis.co.kr...
Page 15
The Expansion Modules are supported a variety of input and output field devices. There are digital and analog input/output modules and special function modules. • Two types of FnBus Message - Service Messaging - I/O Messaging Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL : www.crevis.co.kr...
Reserved for bypass Token. Field GND Field Ground. Field Vcc Field supply voltage (24Vdc). Do not touch data and field power pins in order to avoid soiling and damage by ESD noise. Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL : www.crevis.co.kr...
RJ-45 Description Name Transmit + Transmit - Receive + Receive - Shielded RJ-45 Socket Case Shield The use of an incorrect supply voltage or frequency can cause severe damage to the component. Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL : www.crevis.co.kr...
The data exchange between network adapter and expansion modules is done via an I/O process image data by FnBus protocol. The following figure shows the data flow of process image between network adapter and expansion modules. Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL : www.crevis.co.kr...
A distinction is made between the following states: Init Pre-Operational Safe-Operational and Operational Boot The regular state of each EtherCAT slave after bootup is the OP state. Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL : www.crevis.co.kr...
Page 22
In the Boot state the slave firmware can be updated. The Boot state can only be reached via the Init state. In the Boot state mailbox communication via the file access over EtherCAT (FoE) protocol is possible, but no other mailbox communication and no process data communication. Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL : www.crevis.co.kr...
CANopen. Large parts of the CANopen firmware can be reused. Objects can optionally be expanded in order to account for the larger bandwidth offered by EtherCAT. <Refer to 6.4> Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL : www.crevis.co.kr...
Page 24
The master acts like a layer 2 switch that redirects the frames to the respective devices according to the address information. All internet technologies can therefore also be used in the EtherCAT environment: integrated web server, e-mail, FTP transfer, etc. <Fig. 2> Transparent for all Ethernet Protocols Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL : www.crevis.co.kr...
Page 25
– Mapping of profile type 1 to network technologies – Part 7-304: Generic interface and use of profiles for power drive systems – Mapping of profile type 4 to network technologies Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL : www.crevis.co.kr...
Specification of changeability, e.g. whether it can only be read or can also be written A value – depending upon the parameter the value can be a text, a number or another parameter index. Example) NA-9286 (with ST-1224, ST-2414) CoE directory Index Name...
: In some EtherCAT devices the channel parameters are stored here (as an alternative to the x8000 range). x6000 : Input PDOs ("input" from the perspective of the EtherCAT master) x7000 : Output PDOs ("output" from the perspective of the EtherCAT master) 6.5. EtherCAT Reference EtherCAT Reference Documents http://www.ethercat.org Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL : www.crevis.co.kr...
- EDS: Electronic Data Sheet. - sinking: The method of input and output what device does not have power source. - sourcing: The method of input and output what device have power source. Copyright(C) CREVIS Co.,Ltd Support +82-31-899-4599 URL : www.crevis.co.kr...
Need help?
Do you have a question about the NA-9286 and is the answer not in the manual?
Questions and answers