JAGA ROOMCONTROLLER
Controller for multiple areas (up to 4 zones)
Voor de opstart van de Clima Canal motor(en), zet de uitgangs-
spanning op de Jaga Roomcontroller op minimum 4 Volt.
Pour le démarrage du moteur(s) Clima Canal, la tension de sor-
tie du Jaga Roomcontroller doit être réglée au minimum 4 volts.
Für die Inbetriebnahme der Clima Canal Gebläsemotor (s), den
Regler auf mindestens 4 Volt einstellen.
For startup of the Clima Canal(s) fan motor, adjust the Jaga
Roomcontroller output button to 4 volts.

Advertisement

loading

Summary of Contents for RadiatorFactory JAGA

  • Page 1 Jaga Roomcontroller op minimum 4 Volt. Pour le démarrage du moteur(s) Clima Canal, la tension de sor- tie du Jaga Roomcontroller doit être réglée au minimum 4 volts. Für die Inbetriebnahme der Clima Canal Gebläsemotor (s), den Regler auf mindestens 4 Volt einstellen.
  • Page 2 Page General information LED indication operation mode Connections Connections with External Power Supply Example scheme 1 SECTOR heating Example scheme 1 SECTOR heating & cooling Example scheme 2 SECTORS heating & cooling Technical Data Roomcontroller 4 Zones w w w.theradiatorfactor y.com...
  • Page 3: General Information

    3 LEDs on the left hand side on the front of the zone. If the rated current is exceeded, the output electrician or technician The warranty provided by Jaga differs from prod- controller is switched off and the LED of the relating zone uct to product.
  • Page 4 LED indication operation mode (Power On) Mode: Heating Mode: Cooling Manual setting ventilator speed Connection (by using screw clamps)
  • Page 5 Connections Maximum number of devices per controller:: NO: normaal open contact NO: normal open contact NC: normaal geslotencontact NC: normal closed contact Attention: 3-WAY VALVE 3-WEG VENTIEL ZONE 1 ZONE 2 ZONE 3 ZONE 4 A 24V 50W (suitable for driving (eg) up to 2 Briza or 10 Clima Canal engines) is built into the casing.
  • Page 6 Connections with External Power Supply NO: normal open contact NO: normaal open contact NC: normal closed contact NC: normaal geslotencontact TOESTELLEN DEVICES 3-WEG VENTIEL 3-WAY VALVE ZONE 1 ZONE 2 ZONE 3 ZONE 4 Power supply: - DIN-rail- or wall mounting - safety: UL1310 Class2 - voltage out between 24 - 28 VDC - voltage in 90 - 264 VAC...
  • Page 7 ROOM 1 ROOM 1 ROOM 2 ROOM 3 ROOM 4 ROOM 3 230VAC ROOM 2 Jaga Design Radiator Bypass with pressure difference regulator Bypass with pressure difference regulator Speed-control device Speed-control device Two way valve with motor Two way valve with motor...
  • Page 8 ROOM 4 ROOM 1 ROOM 1 ROOM 2 ROOM 3 ROOM 4 ROOM 3 230VAC ROOM 2 Jaga Design Radiator Water / Icewater Two way valve with motor Speed-control device Bypass with pressure difference regulator Heating system controller Thermostat Three way valve with motor...
  • Page 9 ROOM 3 ROOM 1 ROOM 2 ROOM 3 ROOM 4 ROOM 1 230VAC 230VAC ROOM 2 Jaga Design Radiator Water / Icewater Two way valve with motor Speed-control device Bypass with pressure difference regulator Heating system controller Thermostat Three way valve with motor...
  • Page 11 Technical Data Roomcontroller 4 Zones Physical data Housing: Dimensions 160 x 91 x 61 (h x b x l) Material Plastic, self extinguishing as per UL94-V0 Steering per controller Number of zones Led indication: 1 LED per zone Lights continuously in heating mode / Flashing slowly in cooling mode 3 LED's system operation: Green Power On...
  • Page 12 1012 / versie1 - Jaga N.V.