Download Print this page

Satcom Resources WC1000 Installation Manual page 3

Metrodata wan-in-a-can

Advertisement

INTRODUCTION
1. 2 Performance
Switching and filtering is performed at wirespeed: 148810 packets/second. The WC1000
can handle a traffic level of 4064 packets/second over the E1 link.
1. 3 Safety
The WC1000 should not be connected to cabling which would be required by BS6701 to be
equipped with over-voltage protection. The following ports are designated SELV (Safety
Extra Low Voltage) within the scope of EN41003:
E1 Line (or WAN) port (BNC or RJ45)
4 x 10/100 BaseT Ethernet ports
These ports should only be connected to SELV ports on other equipment in accordance with
EN60950 clause 2.3.
1. 4 Electromagnetic Compatibility
In order to ensure EMC compliance all signal and data cables and connectors must use a
screened connector shell with a screened cable. The cable screen must be terminated to the
screened connector shell and not connected to any pins of the connector. Failure to use the
correct connector may compromise EMC compliance.
1. 5 EN55022 Declaration
The WC1000 is a Class A product. In a domestic environment it may cause radio
interference in which case the user may be required to take adequate measures.
1. 6 FCC Declaration
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radiocommunications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct
the interference at its own expense.