Weather Station
Operation Manual
AM706D
Model:
Document: NLT-AM706D-SSEN
Edition:
V140827

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AM706D and is the answer not in the manual?

Questions and answers

Summary of Contents for Ninglu AM706D

  • Page 1 Weather Station Operation Manual AM706D Model: Document: NLT-AM706D-SSEN Edition: V140827...
  • Page 2 Quick User Guide  Warning function: Power failure, Wind speed (Gust), temperature and humidity alarm.  Mute: Press any button to mute.  Selectable Relative/True speed direction.  Selectable day and night modes.  Direction calibration: After power on, move wind vane toward the ship bow direction, then press the reset button inside junction box.
  • Page 3 Safe Operation Please carefully read this page before operation in order for safe and convenient operation. Warn Prohibit Attention Be sure no water Operation Warn or rain into unit Do not disassemble unit Installation Warn Do not refit unit Power off before privately installation Do not operate...
  • Page 4: Table Of Contents

    Contents Introduction ..............1 Introduction ..................1 Measurement Principle ............... 1 System Introduction ............3 General View ..................3 System Overview ..................4 Technical Requirements ..........5 Basic Parameters ................... 5 Environmental Conditions ............... 5 Technical Parameters ................6 Input and Output ............7 Data transmission for NMEA0183 ............
  • Page 5 Wiring diagram of AM706D back cover ..........27 System internal connection ..............28 System internal wiring diagram ..........28 Wind sensor AM706S - Main unit AM706D ......29 TMP and HUM sensor AM706TH-Main unit AM706D .... 29 Main unit AM706D Power in ............. 30 System external connection ..............
  • Page 6: Introduction

    AM706D is approved by China Classification Society (CCS). The main unit AM706D adopts three mounting methods, table, hung and flush mounting. The wind sensor AM706S should be installed on natural ventilated place, such as mast. Please note, big Radar antenna rotation can disturb the wind measurement.
  • Page 7 Wind sensor sends relative wind direction and speed signal (relative to ship bow and absolute value of angle signal) in digital interface format of RS422 to main unit through junction box. Temperature and humidity sensor provides air temperature and humidity signal in digital interface format of RS485 to main unit through junction box Barometric pressure signal is received from internal IC sensor of main unit.
  • Page 8: System Introduction

    System Introduction General View...
  • Page 9: System Overview

    System Overview Main unit AM706D Application: Measure Barometric pressure and display values and system control Dimension: High 264 x width270 x thickness93 mm Installation: Table, Hanging, Flush mounting Location: Wind Direction and Speed Sensor AM706S Application: Measure relative wind direction and speed, export to Main unit Dimension:...
  • Page 10: Technical Requirements

    Technical Requirements Basic Parameters Dimension: 10 inch TFT Display: Wind direction, speed, temperature, humidity, barometric pressure, print interval, alarm setting. Wind direction simulation range: ±180° Wind direction simulation accuracy: ±1° Input/output port: Wind direction/speed input: 1 channel DC power input: 2 channels Temperature-humidity input:...
  • Page 11: Technical Parameters

    Technical Parameters Wind direction range: 0~360° Wind direction accuracy: ±1° Wind speed range: 1.2~25m/s Wind speed accuracy: ±5%(min 0.1m/s) Min start speed: ≤1.2m/s Temperature range: -20~+80° C Temperature accuracy: ±0.5° C Humidity range: 0~100%RH Humidity accuracy: ±4.5%RH Barometric pressure range: 500~1100hPa Barometric pressure accuracy:...
  • Page 12: Input And Output

    Input and Output Data transmission for NMEA0183 Data transmission adpots NMEA0183 format and conforms IEC61162-1 standards. Date is transmitted in serial asynchronous form. 4800 baud rate is 4800, 8-bit data, no parity bit and one stop bit. GPS data input—RMC $--RMC,hhmmss.ss,A,llll.ll,a,yyyyy.yy,a,x.x,x.x,xxxxxx,x.x,a*h 10 11 12 h<CR><LF>...
  • Page 13: Gps Data Input-Gga Data Input

    GPS data input—GGA data input $--GGA,hmmss.sss,ddmm.mmmm,a,dddmm.mmmm,a,x,xx, 5 6 7 x.x,x.x,M,x.x,M,x.x,xxxx*hh<CR><LF> 11 12 13 UTC of position Latitude Latitude N/S Longitude Longitude E/W GPS quality indicator:0=fix not available or invalid 1= GPS SPS mode, fix valid 2=differential GPS, SPS mode, fix valid 6=Estimated (dead reckoning) mode (7) Number of satellites in use, 00-12, may be different from the number in view...
  • Page 14: Speedlog Data Input--Vbw

    Speedlog data input--VBW Water-referenced and ground-referenced speed data $--VBW,x.x,x.x,A,x.x,x.x,A,x.x,A,x.x,A*hh<CR><LF> (1) Longitudinal water speed, Knots (2) Transverse water speed, Knots (3) Status:water speed, A=data valid, V=data invalid (4) Longitudinal ground speed, Knots (5) Transverse ground speed, Knots (6) Status:ground speed, A=data valid, V=data invalid (7) Stern transverse water speed, Knots (8) Status:stern water speed, A=data valid, V=data invalid (9) Stern transverse ground speed, Knots...
  • Page 15: Main Unit Output --Mda

    Main unit output --MDA $--MDA,x.x,I,x.x,B,x.x,C,x.x,C,x.x,x.x,x.x,C,x.x,T,x.x,M,x.x,N,x.x,M*hh<CR><LF> 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 Barometric pressure Barometric pressure unit, I=inHg Barometric pressure Barometric pressure unit, B=bars Air temperature Temperature unit, C=degree Water temperature Temperature unit, C=degree...
  • Page 16: Operating Instructions

    Operating Instructions Display Display Explanation Press [MODE] to Current switch relative/ relative/tr true mode. wind Press [MODE] to speed switch speed unit. Current Press [MODE] to relative/tr switch relative wind or true mode. direction Anyone of two Power channels power failure supply failure...
  • Page 17: Key Introduction

    Current Barometric Press [MENU] to switch Barometric pressure unit pressure Current TEMP Press [MENU] to switch temperature unit TEMP Press [H.TMP] or [L.TMP] to set alarm value or turn off Alarm Value Gust Alarm Press [GUST] to set alarm value or turn off Input Signal Press [MENU] to open the window and observe input...
  • Page 18: [Power] Power On/Off

    [POWER] Power On/Off Press[POWER 1]to turn on the system,software version is shown at the top left top corner and then the main display. Power Failure Alarm After turning on, it self-checks the both channels of power supply. Anyone channel is disconnected, it will cause Power Failure alarm. When power failure alarm is triggered, the main unit buzzer provides long tone alarm (external alarm will not be on when power failure) and red words ‘Power Failure’...
  • Page 19: [Gust] Gust Alarm

    [GUST] Gust Alarm Press [GUST] left and right arrowheads to set gust alarm limits and the factory setting is OFF. Set Value Unit OFF、1~25 OFF、1~90 km/h OFF、1~49 When current relative/true wind speed is over alarm limits, main unit buzzer and external alerter are turned on, wind value color turns yellow to red and continuously flashing.
  • Page 20: [L.tmp] Low Temperature Alarm

    [L.TMP] Low Temperature Alarm Press left/right arrows of [L.TMP] to set the low temperature alarm and factory setting is OFF. Set Value Unit H.TMP limit should be higher OFF、-20 ~ H.TMP ℃ than L.TMP limit OFF、 -4 ~ H.TMP ℉ L.TEMP <...
  • Page 21: [Print] Printer Setup

    [PRINT] Printer Setup Press left and right arrows of [PRINT] to set print functions. Factory setting value is OFF (print off). Set value:OFF、5s、15s、30s、60s,which is the interval time of auto print. For example, when print setup is 30s, the connected DPU-414 printer will automatically print corresponding data every 30 seconds.
  • Page 22: Dpu-414 Printer Printing Contents

    DPU-414 Printer Printing Contents 1. Relative Wind:250° 5.4m/s True Wind:321° 3.2m/s Relative wind direction and speed Absolute wind direction and speed 2. Temperature:16.2℃ Humidity:64.0%RH Barometer:1008hPa Temperature Relative humidity Air pressure 3. 03:08 32° 01.2524N 118° 42.0208E Heading:190.4° Speed:0.0Knots E East Heading Speed Time N Northern...
  • Page 23: [Menu]

    [MENU] Press [MENU] to open menu window Press up/down arrow buttons for main options and left/right buttons for settings. Press [OK] to save the set values and exit or automatically save and exit without operation in 10s. Menu item Set Value Explanation Input Display OFF Turn on/off input signal window,...
  • Page 24: Maintenance

    Maintenance Main Unit The main unit is maintenance-free. If doing the cleaning, use soft cloth and mild detergent, and avoid water drop. Sensor Part When there is ice or dirt on sensor to disturb the normal work, please clear in time. Regularly check external mounting bolts to avoid looseness and the abrasion and ageing of cables When the equipment breaks down, please contact our engineers of...
  • Page 25: Calibration

    Calibration Calibration of AM706 wind vane after finishing the installation. Press [POWER] to turn on Move wind vane arrow parallel Keel line to the keel line, toward to the side. Then open junction box. Groove Press the calibration button in the waterproof junction box display relative...
  • Page 26: Installation

    Installation Main unit Installation AM706D The Main unit has three mounting methods, table, hanging and flush mounting. Table and Hanging Mounting The holder supplied by original factory setting is used in table and hung mounting. Unit:mm...
  • Page 27: Flushing Mounting

    Flushing Mounting The holder supplied by original factory setting should be used in flushing mounting. Embed the main unit into the bridge control panel (the dimension is shown below) and tighten the rotary knob to fix the main unit. Unit:mm...
  • Page 28: Power Adapter Installation

    Power Adapter Installation Power adapter ( GA-240150) , AC220/110V to DC24V, adapter holder and screws. Unit:mm...
  • Page 29: Installation Of Wind Sensor Am706S

    Installation of Wind sensor AM706S ind Vane and Wi nd Cup Installation [ Wind Vane ] Wind vane is installed on the top of sensor holder, successively into black seal ring, plane washer, spring washer and 2 screw nuts. The two screw nuts should be tightened and then insert the cotter. [ Wind Cup ] Wind cup is installed on the bottom of sensor holder, successively into plane washer, spring washer and 2 screw nuts.
  • Page 30: Integral Installation

    1+ 2- 3B 4A. [ Calibration ] After the installation of main unit of wind sensor, do the calibration of wind direction based on Calibration. AM706S junction box terminals NMEA AM706D back cover terminals 后盖端子...
  • Page 31: Temperature And Humidity Sensor Installation

    Temperature and Humidity Sensor Installation Temperature and Humidity Sensor AM706TH Temperature and humidity sensor AM706THcan be installed in hung and fixed link mounting methods. AM706TH with M10 bolt is installed on the vertical wall or with U-blot M10 is installed over vertical pipe fitting. Unit:mm...
  • Page 32: Wiring Explanation

    Wiring explanation Wiring diagram of AM706D back cover...
  • Page 33: System Internal Connection

    System internal connection System internal wiring diagram...
  • Page 34: Wind Sensor Am706S - Main Unit Am706D

    Wind sensor AM706S - Main unit AM706D 4-core screened cable with external diameter 4mm~6mm is connected with 4 terminals +、-、B、A through glands of junction box. Please pay attention on wire colors and sequence in order to correctly connect the wiring terminals of back cover, 1+ 2- 3B 4A.
  • Page 35: Main Unit Am706D Power In

    Main unit AM706D Power in Connect DC cable and ac power adapter (GA-240150) with ship power.
  • Page 36: System External Connection

    System external connection System external wiring diagram...