Quick User Guide Warning function: Power failure, Wind speed (Gust), temperature and humidity alarm. Mute: Press any button to mute. Selectable Relative/True speed direction. Selectable day and night modes. Direction calibration: After power on, move wind vane toward the ship bow direction, then press the reset button inside junction box.
Page 3
Safe Operation Please carefully read this page before operation in order for safe and convenient operation. Warn Prohibit Attention Be sure no water Operation Warn or rain into unit Do not disassemble unit Installation Warn Do not refit unit Power off before privately installation Do not operate...
Contents Introduction ..............1 Introduction ..................1 Measurement Principle ............... 1 System Introduction ............3 General View ..................3 System Overview ..................4 Technical Requirements ..........5 Basic Parameters ................... 5 Environmental Conditions ............... 5 Technical Parameters ................6 Input and Output ............7 Data transmission for NMEA0183 ............
Page 5
Wiring diagram of AM706D back cover ..........27 System internal connection ..............28 System internal wiring diagram ..........28 Wind sensor AM706S - Main unit AM706D ......29 TMP and HUM sensor AM706TH-Main unit AM706D .... 29 Main unit AM706D Power in ............. 30 System external connection ..............
AM706D is approved by China Classification Society (CCS). The main unit AM706D adopts three mounting methods, table, hung and flush mounting. The wind sensor AM706S should be installed on natural ventilated place, such as mast. Please note, big Radar antenna rotation can disturb the wind measurement.
Page 7
Wind sensor sends relative wind direction and speed signal (relative to ship bow and absolute value of angle signal) in digital interface format of RS422 to main unit through junction box. Temperature and humidity sensor provides air temperature and humidity signal in digital interface format of RS485 to main unit through junction box Barometric pressure signal is received from internal IC sensor of main unit.
System Overview Main unit AM706D Application: Measure Barometric pressure and display values and system control Dimension: High 264 x width270 x thickness93 mm Installation: Table, Hanging, Flush mounting Location: Wind Direction and Speed Sensor AM706S Application: Measure relative wind direction and speed, export to Main unit Dimension:...
Input and Output Data transmission for NMEA0183 Data transmission adpots NMEA0183 format and conforms IEC61162-1 standards. Date is transmitted in serial asynchronous form. 4800 baud rate is 4800, 8-bit data, no parity bit and one stop bit. GPS data input—RMC $--RMC,hhmmss.ss,A,llll.ll,a,yyyyy.yy,a,x.x,x.x,xxxxxx,x.x,a*h 10 11 12 h<CR><LF>...
GPS data input—GGA data input $--GGA,hmmss.sss,ddmm.mmmm,a,dddmm.mmmm,a,x,xx, 5 6 7 x.x,x.x,M,x.x,M,x.x,xxxx*hh<CR><LF> 11 12 13 UTC of position Latitude Latitude N/S Longitude Longitude E/W GPS quality indicator:0=fix not available or invalid 1= GPS SPS mode, fix valid 2=differential GPS, SPS mode, fix valid 6=Estimated (dead reckoning) mode (7) Number of satellites in use, 00-12, may be different from the number in view...
Main unit output --MDA $--MDA,x.x,I,x.x,B,x.x,C,x.x,C,x.x,x.x,x.x,C,x.x,T,x.x,M,x.x,N,x.x,M*hh<CR><LF> 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 Barometric pressure Barometric pressure unit, I=inHg Barometric pressure Barometric pressure unit, B=bars Air temperature Temperature unit, C=degree Water temperature Temperature unit, C=degree...
Operating Instructions Display Display Explanation Press [MODE] to Current switch relative/ relative/tr true mode. wind Press [MODE] to speed switch speed unit. Current Press [MODE] to relative/tr switch relative wind or true mode. direction Anyone of two Power channels power failure supply failure...
Current Barometric Press [MENU] to switch Barometric pressure unit pressure Current TEMP Press [MENU] to switch temperature unit TEMP Press [H.TMP] or [L.TMP] to set alarm value or turn off Alarm Value Gust Alarm Press [GUST] to set alarm value or turn off Input Signal Press [MENU] to open the window and observe input...
[POWER] Power On/Off Press[POWER 1]to turn on the system,software version is shown at the top left top corner and then the main display. Power Failure Alarm After turning on, it self-checks the both channels of power supply. Anyone channel is disconnected, it will cause Power Failure alarm. When power failure alarm is triggered, the main unit buzzer provides long tone alarm (external alarm will not be on when power failure) and red words ‘Power Failure’...
[GUST] Gust Alarm Press [GUST] left and right arrowheads to set gust alarm limits and the factory setting is OFF. Set Value Unit OFF、1~25 OFF、1~90 km/h OFF、1~49 When current relative/true wind speed is over alarm limits, main unit buzzer and external alerter are turned on, wind value color turns yellow to red and continuously flashing.
[L.TMP] Low Temperature Alarm Press left/right arrows of [L.TMP] to set the low temperature alarm and factory setting is OFF. Set Value Unit H.TMP limit should be higher OFF、-20 ~ H.TMP ℃ than L.TMP limit OFF、 -4 ~ H.TMP ℉ L.TEMP <...
[PRINT] Printer Setup Press left and right arrows of [PRINT] to set print functions. Factory setting value is OFF (print off). Set value:OFF、5s、15s、30s、60s,which is the interval time of auto print. For example, when print setup is 30s, the connected DPU-414 printer will automatically print corresponding data every 30 seconds.
DPU-414 Printer Printing Contents 1. Relative Wind:250° 5.4m/s True Wind:321° 3.2m/s Relative wind direction and speed Absolute wind direction and speed 2. Temperature:16.2℃ Humidity:64.0%RH Barometer:1008hPa Temperature Relative humidity Air pressure 3. 03:08 32° 01.2524N 118° 42.0208E Heading:190.4° Speed:0.0Knots E East Heading Speed Time N Northern...
[MENU] Press [MENU] to open menu window Press up/down arrow buttons for main options and left/right buttons for settings. Press [OK] to save the set values and exit or automatically save and exit without operation in 10s. Menu item Set Value Explanation Input Display OFF Turn on/off input signal window,...
Maintenance Main Unit The main unit is maintenance-free. If doing the cleaning, use soft cloth and mild detergent, and avoid water drop. Sensor Part When there is ice or dirt on sensor to disturb the normal work, please clear in time. Regularly check external mounting bolts to avoid looseness and the abrasion and ageing of cables When the equipment breaks down, please contact our engineers of...
Calibration Calibration of AM706 wind vane after finishing the installation. Press [POWER] to turn on Move wind vane arrow parallel Keel line to the keel line, toward to the side. Then open junction box. Groove Press the calibration button in the waterproof junction box display relative...
Installation Main unit Installation AM706D The Main unit has three mounting methods, table, hanging and flush mounting. Table and Hanging Mounting The holder supplied by original factory setting is used in table and hung mounting. Unit:mm...
Flushing Mounting The holder supplied by original factory setting should be used in flushing mounting. Embed the main unit into the bridge control panel (the dimension is shown below) and tighten the rotary knob to fix the main unit. Unit:mm...
Installation of Wind sensor AM706S ind Vane and Wi nd Cup Installation [ Wind Vane ] Wind vane is installed on the top of sensor holder, successively into black seal ring, plane washer, spring washer and 2 screw nuts. The two screw nuts should be tightened and then insert the cotter. [ Wind Cup ] Wind cup is installed on the bottom of sensor holder, successively into plane washer, spring washer and 2 screw nuts.
1+ 2- 3B 4A. [ Calibration ] After the installation of main unit of wind sensor, do the calibration of wind direction based on Calibration. AM706S junction box terminals NMEA AM706D back cover terminals 后盖端子...
Temperature and Humidity Sensor Installation Temperature and Humidity Sensor AM706TH Temperature and humidity sensor AM706THcan be installed in hung and fixed link mounting methods. AM706TH with M10 bolt is installed on the vertical wall or with U-blot M10 is installed over vertical pipe fitting. Unit:mm...
Wind sensor AM706S - Main unit AM706D 4-core screened cable with external diameter 4mm~6mm is connected with 4 terminals +、-、B、A through glands of junction box. Please pay attention on wire colors and sequence in order to correctly connect the wiring terminals of back cover, 1+ 2- 3B 4A.