petMAP graphic Manual

Blood pressure measurement device

Advertisement

Blood Pressure Measurement Device
Developed by:
Manufactured,
Distributed and
Serviced by:
www.petmap.com
(800) 231-6370
(813) 289-5555
 Digital display of systolic,
diastolic, mean arterial
pressure and heart rate.
 Real-time display of the
oscillometric "envelope".
 Graphical trend of
measurement session values.
 Real-time calculation and
display of the NSV.
 Tabular list of measurement
session values.
Patents Pending
1
Ramsey Medical, Inc.

Advertisement

Table of Contents
loading

Summary of Contents for petMAP graphic

  • Page 1 “envelope”. Developed by:  Graphical trend of measurement session values.  Real-time calculation and display of the NSV. Manufactured,  Tabular list of measurement Distributed and Serviced by: session values. www.petmap.com (800) 231-6370 (813) 289-5555 Patents Pending Ramsey Medical, Inc.
  • Page 2 BP. The measurement process is an art, a skill, and a science all in one . . . when done well. The best way to learn to use the petMAP is to practice taking readings on your finger. This will allow you to get comfortable with the device prior to using it on patients.
  • Page 3: Table Of Contents

    Table of Contents Description Applications / Advantages Controls and Indicators General Information and Helpful Tips Operating Instructions Blood Pressure Values Battery Considerations/Replacement CritterCuff™/RamseyCuff™ Information 20 Maintenance Troubleshooting Specifications Warranty Repairs Product Information Explanation of Symbols Power/Page Button Multi-Function Button...
  • Page 4: Description

    “gold standard” for BP. This unique accuracy enhancing feature (PPO—petMAP Proprietary Optimization) is proprietary to Ramsey Medical, Inc., and is only available with petMAP and other Ramsey Medical BP measurement devices. petMAP utilizes the oscillometric method which simplifies the measurement of blood pressure in companion animals.
  • Page 5 Also, since petMAP is quiet, it does not alarm the animal like the unfamiliar sounds from the Doppler unit’s speaker box.
  • Page 6 Features and Benefits petMAP graphic is a technologically advanced oscillometric BP measurement device designed for use in the broadest range of patient sizes and blood pressures. Compare its features and benefits in the chart below:...
  • Page 7: Controls And Indicators

    1) Turns the device On. 2) Once on, changes screen views from the measurement page to the graphic results page to the tabular results page. 3) Pressing and holding the Power/Page button for 4 seconds will turn petMAP Off. This is also possible by pressing both the Power/Page and Multi Function buttons simultaneously.
  • Page 8 Power ON Indicator: Iluminates green when the unit is powered. (In order to conserve battery life, the petMAP will automatically shut off after 10 minutes of “no use”). Low Battery Indicator: The low battery indicator may flash occasionally during a determination. This is a warning for battery replacement.
  • Page 9 This non-optimized mode should be used when: 1. The user wants values that better correlate to other oscillometric devices and/or Doppler values. 2. The use is measuring on a species other than a cat or a dog. Deflate Trigger: When locked in up position (valve closed), cuff is ready for inflation.
  • Page 10 Measurement Page NSV Values for systolic, diastolic, heart rate and (MAP) Session’s values plotted with elapsed time Graphic Results Page Session’s Results Column 1: Approx. time (min) since Power ON Column 2: Systolic/diastolic Column 3: (MAP) Column 4: heart rate...
  • Page 11: General Information And Helpful Tips

    BP. Also, a calm animal is essential. petMAP is specifically designed to allow the user to get good determinations while also calming the animal. Even so, many animals will require extra time and patience. If an animal is restless, giving them 8 to 10 minutes to calm down may help and should restore their BP to their usual level.
  • Page 12: Operating Instructions

    There should be no weight bearing or pressure on the limb on which the cuff is being used. Do not attach cuff to petMAP yet. 2. Refer to “CritterCuff™ Information” section to explain selection of proper Cuff Size and Cuff Fit.
  • Page 13 (Approximately 1/2” (Between dewclaw and heel) from base of tail) 4. Turn the petMAP ON. If there is a “Nominal Session BP” (NSV) from the previous BP measurement session, it will be displayed until the cuff pressure is raised over 30 mmHg.
  • Page 14 (up) position. The petMAP’s internal electronic valve will automatically deflate the cuff pressure in a series of steps. The petMAP can be placed on the surface upon which the animal is resting so that the operator has both hands to pet and calm the animal during the determination.
  • Page 15 9. When the BP determination is complete, the air is purged from the cuff automatically or by using the deflate trigger. The petMAP will display BP and Heart Rate as follows: Systolic Diastolic Heart rate Mean Arterial Pressure 10. To obtain another reading, just re-inflate the cuff. This may be done from any of the display screens.
  • Page 16 The GOOD, the BAD, and the UGLY . . . BP determinations that are showing ragged oscillometric envelopes like the BAD and the UGLY examples should be terminated while in process; the patient should be calmed to reduce motion before a new determination is started. GOOD UGLY...
  • Page 17 Addressing BP Measurement Difficulties : Determine and correct the reason for the BP measurement difficulty. Often the problem is one or more of: 1) movement during the determination (calm the animal) 2) cuff is not proper size or snugness (check size/fit) 3) initial cuff inflation is too low (pump cuff higher) Remember that measuring accurate BP on animals is not trivial and attention to every detail is important.
  • Page 18: Blood Pressure Values

    10-20% higher than Doppler or other oscillometric devices. If correlation of petMAP BP readings with other BP devices (other than direct intra-arterial readings) is desired by the user, petMAP should be used in the non-optimized mode (described in the Controls and Indicators section).
  • Page 19: Battery Considerations/Replacement

    Consensus Statements, published on this topic. Battery Considerations In order to maximize battery life, petMAP is designed to turn the display completely OFF following a determination when the unit is motionless for more than 12 seconds. If the unit is not re-pressurized for a new determination within 10 minutes, petMAP will turn OFF.
  • Page 20: Battery Replacement

    2) retighten the screw firmly (Do not over tighten)  Always replace both batteries  Do not mix types, brands, or models of batteries in petMAP  Be certain the batteries are installed according to the polarity symbols marked on the battery compartment.
  • Page 21: Crittercuff /Ramseycuff Information

    The Ramsey Medical, Inc. CritterCuffs and larger RamseyCuffs are designed specifically to be used with the petMAP. Using any other brand of cuffs may result in inaccurate BP readings, or even a failure to function and is strongly discouraged for these reasons.
  • Page 22 For accuracy of the reading, it is essential that the proper cuff be selected and applied snugly to the limb. Only CritterCuffs should be used with the petMAP since the cuff and unit form a system specifically designed for sensitive and accurate blood pressure measurement in companion animals.
  • Page 23: Maintenance

    5. Check LoBat light. Replace batteries if indicated. 6. Zero not set properly on power up. Make sure there is no pressure in the system when the petMAP is first powered up by opening the deflate trigger first and/or removing the cuff connector from the unit to assure...
  • Page 24 1. Check cuff connection. 2. Verify deflate trigger is in the up position (valve closed position). 3. Check cuff and hose for leaks or damage. Strange petMAP behavior. 1. Replace batteries. If batteries do not fix problem, contact Customer Support.
  • Page 25: Specifications

    Specifications For Animal Use Only Method of BP Measurement: Oscillometric. Accuracy optimized for species (dog/cat) and blood pressure cuff site (forearm, tail, hind foot). Parameters Measured: Systolic, diastolic, mean arterial pressure (MAP), and heart rate (HR). Modes: Semi-Automatic with auto deflate Blood Pressure Range: 30-260 mmHg Heart Rate Range:...
  • Page 26: Warranty

    The Ramsey Medical petMAP is distributed and supported in the USA by: CardioCommand, Inc. 4920 W. Cypress St., Ste. 110 Tampa, FL 33607 www.cardiocommand.com 800-231-6370 or 813-289-5555 petMAP may also be purchased in both the USA and internationally from other selected distributors.
  • Page 27: Product Information

    Product Information petMAP™ System (includes 7 CritterCuffs sizes 2.0 - 5.5 cm) 1 Year Extended Service Warranty CritterCuff, 2.0 CritterCuff, 2.5 CritterCuff, 3.0 CritterCuff, 3.5 CritterCuff, 4.0 CritterCuff, 4.5 CritterCuff, 5.5 CritterCuff, 6.5 CritterCuff, 8.0 RamseyCuff, 10.0 RamseyCuff, 13.0...
  • Page 28 RAMSEY Medical, Inc. Tampa, FL 33607 petMAP, CritterCuff and RamseyCuff are registered trademarks of Ramsey Medical, Inc. Patents Pending Developed by: Ramsey Medical, Inc. Manufactured, Distributed and Serviced by: CardioCommand, Inc. 4920 W. Cypress St. Suite 110 Tampa, FL 33607...

Table of Contents