Save the telephone numbers by SMS ................20 Command and verify the status of the relays by SMS ............23 Verify the current status of the Musitel unit by SMS ............25 Connecting the Musitel ...................... 26 Light signals ........................26 Commands by telephone calls ...................
GSM network. Caution : If by distraction you have inserted or taken the SIM card out while the Musitel was plugged into a power supply, you must, by using an ordinary GSM, make a phone call where the person being called answers. This will unblock the SIM card..
Musitel. This screen is used only for «Troubleshooting», for example to analyze the events when faults have been detected. As long as you are connected to the Musitel, either by USB cable or Modem, you can follow in real time, the commands received and the messages sent by the equipment.
To write the new configuration for the Musitel 742 To save the existing configuration on a file on the PC. To open a configuration file. To change the password. Default password : 1111 To compare the parameters with those of the Musitel 742 Page 5...
Alarm Inputs a) Choose the “Zones” tab Before modifying the Musitel configuration, it is wise to start by reading the existing configuration by using the icon a) Zone Normally Open = at the rest position, the input is “in the air”, Normally closed = at the rest position, the input is linked to the ground.
11.8 V or 23.6 V for more than 60 seconds. “Battery OK” : Sends an alarm when the battery voltage of the Musitel is at normal level, above 11.8 V or 23.6 V for more than 60 seconds.
“Phone numbers..” screen a) In case of alarm, the equipment can call 4 numbers to send either an SMS or a voice mail. b) Acknowledgement : requests the acknowledgment of the alarm, it concerns the voice messages received. If there is no acknowledgment of the alarm, the transmitter will continue to call.
Page 9
d) SMS forwarding : it is the number(s) to which the SMS received by the SIM card will be transferred. It can be useful for the pre-paid cards which receive SMS's with the available credit. e) Monitoring station Phone numbers : It is useful when used with Alarm Centers.
“Relay outputs” Screen The relays can be commanded either - by sending an SMS with or without an SMS confirmation in return; - by a telephone call from one of the 4 numbers previously saved; - by a telephone call from any phone number, protected by a password; - by relationship to the status of one or several alarm inputs;...
Page 11
Bi-stable function : If the chosen value is 255, the relay will work in the bi-stable function. Once the relay is activated it will not come back to its normal position automatically. In order to change its position, a command must be sent either by a telephone call or by an SMS.
“Alarm Settings” screen a) Arm/Disarm method Arm = arming. When the unit is “armed” all functions are active all the time. Disarm = desarming When the unit is “disarmed”, only the inputs checked for 24hr/24 will be active all the time. The other inputs will be active only when the unit is armed. Arming and disarming the unit allows monitoring the situation, for example, only when the building is empty.
Page 13
From 1 to 255 hours. 0 = no SMS. Test Report Time The first day of each month, at the chosen time, the Musitel 742 unit will send an SMS Test Report. After that, it will send SMS's regularly, every X hours, depending on the value entered for the “Test Report Frequency”.
• configure the Musitel 742 by a telephone call except for the users for which the “Caller ID” is “1 No pwd req” • configure the Musitel 742 by SMS except for the users for which the “Caller ID” is “1 - No pwd req”...
“Event list” screen Click on the “Event List” icon on the “Module status” screen Click on “start event log download” T1, T2, ... T4 are the telephone calls made to the numbers 1, 2, ...4. S1, S2, ... S4 are the SMS sent to the numbers 1, 2, ...4. C1, C2 are the telephone calls made to the Alarm Center.
Recording a voice message by using a telephone call 8 voice messages can be recorded for the 4 alarm inputs of the Musitel : Each input can have 2 voice messages, the odd number will be the alarm message and the even number will be the message for when the situation has come back to normal.
Page 17
Example : Ecoute du message vocal 4 (entrée Z2 - Restore) ! Enter the password: 91111# (password accepted: 3 beeps) ! Listening the existing voice message: 8004# (listen the message) If you wish to record message number 1 and then hear it: Call, then dial 91111# >then dial>...
Command and verify the status of the relays by a telephone call A simple telephone call to the Musitel SIM card number allows you to open or close the relay contacts. These commands can also be sent by SMS – see further on this manual.
91111# (password accepted: 3 beeps) ! Disarm the Musitel : 0# (3 beeps) 4. Status of the Musitel – Armed or Disarmed This function allows you to know if the Musitel is currently armed or disarmed Command Description Musitel Response...
Save the telephone numbers by SMS Several commands can be sent in one message, but the characters and # must be used to indicate the beginning and the end of each SMS ( for the beginning and # for the end). The different commands will be separated by a comma “,”..
Page 22
= Password = End of SMS To erase a GSM number to which the SMS received by the Musitel are forwarded: The SMS received by the unit's SIM card will no longer be forwarded to this GSM once it is erased.
Page 23
message shall be forwarded (1 ou 2) = separates the commands = Password 1111 = Password = End of SMS Page 23...
Command and verify the status of the relays by SMS Commands for the relays : Command SMS Description Activate relay 1, bi-stable mode. R1=ON, PWD=yyyy, CRQ# If needed, replace “yyyy” by the password. Request for a confirmation SMS R2=ON, PWD=yyyy, CRQ# Activate relay 2, bi-stable mode.
Page 25
The command will be: R1=ON, PWD=1111# (If the password is 1111). ! the command is sent by a number that is not saved in the Musitel. The user does not request a confirmation SMS. The command will be : R1=ON, PWD=1111, CRQ#...
Time left before deactivation of relay 1. R2=ON Permanent The relay is permanently active Time: 28.11.2009 14:18 Date and time of the internal Musitel clock GSM: 23 Value for the GSM network signal, values between 0 and 31. 31 = max.
Connecting the Musitel Supply 9 to 24 VDC Negative terminal of supply + common for alarm inputs Alarm input 1 Alarm input 2 Alarm input 3 Alarm input 4 NO1 relay R1 (open at rest) NO2 relay R2 (open at rest) Alarm inputs: NO = normaly open, on the rest position the input value is 1, the contact is “in the air”...
Status request Arm - Disarm 3 beeps = Disarm, 6 beeps = Arm GSM network signal request Deactivate relay 1 of the Musitel confirmation by 3 beeps Deactivate relay 2 of the Musitel confirmation by 3 beeps Activate relay 1 of the Musitel...
Add a user telephone number to contact in Ux=telephone number,PWD=yyyy# case of alarm. yyyy = password x = musitel user number 1,2,3 or 4. Ux=, PWD=yyyy# Erase a user. yyyy = password x = musitel user number 1,2,3 or 4.
Page 30
RESET, PWD=yyyy, CRQ# Cancels all existing values for all parameters and replaces them by the default values. yyyy = password PWD=yyyy yyyy = password Request for a confirmation Forces the update of the internal watch of the Musitel Page 30...
Need help?
Do you have a question about the 742 and is the answer not in the manual?
Questions and answers