Bism Dive Demo Solis Operating Manual

Bism Dive Demo Solis Operating Manual

Dive computer
Table of Contents

Advertisement

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Dive Demo Solis and is the answer not in the manual?

Questions and answers

Summary of Contents for Bism Dive Demo Solis

  • Page 2: Introduction

    If you have any queries regarding the Dive Computer or the informa- tion contained in this manual, please feel free to contact our company at the following address. Bism CORPORATION TOOK Bldg. 3F, 16-8, Tomizawa-cho, Nihonbashi, Chuo-ku, Tokyo 103-0006 Japan Phone: +81-3-5640-8126 Fax: +81-3-5640 -8131 E-mail: info@bism.co.jp...
  • Page 3: Important Information

    IMPORTANT INFORMATION Safety Precautions It is vital to safety that you use and maintain your Dive Computer correctly and have it inspected periodically. Carefully read and understand the advice on safety given in this manual before diving. We use a various symbols in this manual and on the product indication to have you use the product correctly and safely, and to prevent the danger and damage to the property of you and other people.
  • Page 4 IMPORTANT INFORMATION Danger ●Before use of this product, please recognize handling methods, warnings and cautions in this manual. In addition, please understand how to use it before you actually use it in the ocean. ●When the warnings of decompression stop violation and violation gauge are displayed, always cancel the diving of the day, and a symptom like decompression sickness appears, see a specialist doctor for the medical examination.
  • Page 5 IMPORTANT INFORMATION Warning ●Use other equipment as backup (a depth gauge, diver’s watch, etc.) with this product together when using this product. ●This product does not measure, display or control your remaining air in a tank. Use a pressure gauge to check your air supply.
  • Page 6 IMPORTANT INFORMATION Caution ●Please keep a record of the data memorized in this product in the notebook, etc. Memory data may be lost by trouble, repair and low battery of the product. ●When you watch the information displayed by this product, for the prevention of the unexpected injury and accident, please do it at the place where the safety is secured enough.
  • Page 7 IMPORTANT INFORMATION Caution ●Though magnetism does not affect the operation of the product, please be careful that it affects the precision if the product itself becomes magnetized. In addition, please also be careful that the extremely strong magnetism such as the medical equipment causes malfunction and damage of electronic parts.
  • Page 8: Table Of Contents

    CONTENTS  ◆Introduction ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ ∇Important Information  ・・・・・・・・・・・・・・・・・・・・・・・・・・  ◆Safety Precautions ・・・・・・・・・・・・・・・・・・・・・・・・・・・ ∇Contents ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ ∇Names of Parts, Main Functions and Special Features ・・・・・・・・・・・・ ∇Before Use ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・  ◆Confirmation of Charging Amount ・・・・・・・・・・・・・・・・・・・・・ ∇Charge by Light (Solar Charge) ・・・・・・・・・・・・・・・・・・・・・・  ◆How to Charge  ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・  ◆Shortage of and Out of Battery ・・・・・・・・・・・・・・・・・・・・・  ◆Charging Time ・ ・・・・・・・・・・・・・・・・・・・・・・・・・・・・  ◆Charging Level Warning ・・・・・・・・・・・・・・・・・・・・・・・・・...
  • Page 9 CONTENTS  ◆High Oxygen Accumulation Alarm (High O2 Alarm)・・・・・・・・・・・・・・  ◆High Partial Pressure of Oxygen Alarm (High PO2 Alarm)・・・・・・・・・・  ◆Violation Gauge Warning ・・・・・・・・・・・・・・・・・・・・・・・・・  Log Mode (LOG)・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・  ◆Enter the Log Mode・・・・・・・・・・・・・・・・・・・・・・・・・・・・  ◆Check a Log ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・  ◆Button Operation・・・・・・・・・・・・・・・・・・・・・・・・・・・・・  ◆Check a History ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ ∇Plan Mode (PLAN)・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・  ◆Check a Plan・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・...
  • Page 10 CONTENTS  ◆Summer Time (DST) Setting  ・・・・・・・・・・・・・・・・・・・・・・・ ∇Barometric Pressure and Temperature (BARO) ・・・・・・・・・・・・・・・・  ◆Barometric Pressure and Temperature Measuring  ・・・・・・・・・・・・・ ∇Illumination ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・  ◆Turn the Auto Light Switch On and Off  ・・・・・・・・・・・・・・・・・ ∇Other Settings ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・  ◆Turn the Button Operation Tone On and Off ・・・・・・・・・・・・・・・  ◆Illumination Duration Setting ・・・・・・・・・・・・・・・・・・・・・...
  • Page 11: Names Of Parts, Main Functions And Special Features

    NAMES OF PARTS, MAIN FUNCTIONS AND SPECIAL FEATURES DIVE DEMO SOLIS Buckle Retainer Belt M Button P Button Pressure sensor A Button L Button B Button...
  • Page 12 NAMES OF PARTS, MAIN FUNCTIONS AND SPECIAL FEATURES This product has 5 operation buttons. P Button M Button Upper left - M (Mode) button Upper right - P (Plan) button Lower right - L (Log) button Lower left - A (Adjust) button Lower center - B (Backlight) button A Button In this manual, they are described under the name of M but-...
  • Page 13 NAMES OF PARTS, MAIN FUNCTIONS AND SPECIAL FEATURES Functions as Dive computer This product has 4 kinds of dive computer modes. ○Dive Mode “DIVE” display No-decompression limit Safety stop Decompression diving Nitrox ○Surface Mode “TIME 1 and 2” display Desaturation time Surface time ○Log Mode “LOG”...
  • Page 14 NAMES OF PARTS, MAIN FUNCTIONS AND SPECIAL FEATURES □ Time accuracy ±15 seconds a month □ Sensor precision Bearing sensor Within ±10° Within ±2 ℃ Temperature sensor Pressure sensor ±1% + 0.5m □ Measuring interval Depth measurement 1 sec. Water temperature measurement 1 sec.
  • Page 15: Before Use

    BEFORE USE Before using this product, “charge” and “the setting of the time and date” are necessary. Please use it after charge it enough and set the display of time and date. Confi rmation of Charging Amount ■Charging status Please confi rm the charging status by “H”, “M” and “L” displays at the right side of the screen.
  • Page 16: Charge By Light (Solar Charge)

    BEFORE USE Charge by Light (Solar Charge) This product works with battery (rechargeable battery) which charges the electricity generated by solar panel. ●Solar panel is united with dial. ●When the dial gets enough light, it generates and charges. When you use it, please keep it in mind to expose the dial (solar panel) to light. How to charge When you take off the product, put it in a bright place getting light.
  • Page 17: Shortage Of And Out Of Battery

    CHARGE BY LIGHT (SOLAR CHARGE) Shortage of and Out of Battery DISPLAY CONDITION OF THIS PRODUCT CHARGING STATUS Good condition Normal condition When just a letter of "CHG" flashes, and other indication Just “CHG” flashes lights up as usual, it cannot move to the dive mode. You cannot use it in diving.
  • Page 18: Charging Time

    and “CHG” flashes some functions including the indication of the current time. When just "CHG" flashes, and all other indication Just “CHG” flashes Good condition Normal condition disappear, you cannot use all functions. (All lights out) CHARGE BY LIGHT (SOLAR CHARGE) When just a letter of "CHG"...
  • Page 19: Power Saving Function

    Watch Mode and Surface Mode Letter of “CHG” flashes Dive Mode "WARNING! ! BATT " is displayed 5 times as flowing, and at the same time, “M” icon at the right side of the screen flashes. Alarm sounds for six seconds. CHARGE BY LIGHT (SOLAR CHARGE) *The warning continues until the charging level becomes "H".
  • Page 20: Watch Mode

    WATCH MODE In Watch Mode, you can set and display the current time and a date. Display is switched by depressing the A button. Watch Mode 1 Watch Mode 2 Day of the week display Seconds display Seconds Day of the week Date A button Time...
  • Page 21: Home City And Summer Time Setting

    HOME CITY SETTING AND THE TIME ADJUSTING Home City and Summer Time Setting 1) While in the Watch Mode, continue to depress the A button for more than 2 seconds. Release the button when a City Code and its city name are displayed as flowing following the display of “CITY”...
  • Page 22 HOME CITY SETTING AND THE TIME ADJUSTING Watch and Date Setting Please do not set the watch and date before setting Home City. 1) While in the Watch Mode, continue to depress A button for more than 2 seconds. Release the button when a City Code and its city name are displayed as flowing following the display of “CITY”...
  • Page 23 HOME CITY SETTING AND THE TIME ADJUSTING 3) In each setup item, depress P button (UP) or L button (DOWN) to change the setup. Display Item to Change Button TYO・・・Change the city code. ・・・・・・・・・・・・・・・・P or L button OFF・・・Switch the Summer Time (DST) and Standard Time. ・・・P button 12H・・・Switch the 12-hour and 24-hour format.
  • Page 24: Dive Mode (Dive)

    DIVE MODE (DIVE) DIVE MODE No button operation Surface Mode Watch Mode When you ascend to the depth of 1.5m When you ascend to the depth of 1.5m When you descend deeper than 1.5m for less than 20 seconds deeper than 1.5m for less than 20 seconds Page 32 Page 32 WATER...
  • Page 25: No-Decompression Diving

    DIVE MODE (DIVE) No-decompression Diving A Button M Button P Button M Button No button operation THE WATER Direction Depth Basic reading Screen Pagw 29 Pagw 28 No-decompression Limit Basic Screen Pagw 28 Pagw 28 Maximum Depth Watch Screen Screen Pagw 29 Pagw 30 Pagw 30...
  • Page 26 DIVE MODE (DIVE) In the Dive Mode, it displays important information necessary at the time of scuba diving. No-decompression limit Elapsed dive time Current depth Tissue Loading Bar Graph Oxygen Accumulation (O2) or (TLBG) Partial Pressure of Oxygen (PO2) Bar Graph This product enters to Dive Mode automatically within 20 seconds after entry and sensing pressure of the water equivalent to the depth of 1.5m.
  • Page 27 DIVE MODE (DIVE) When in no-decompression diving, the following information is displayed. ○No-decompression Limit (NDL)・・・Possible time to stay at the current depth as no-decompression. *Maximum 200 minutes. ○Current Depth (DEPTH)・・・・・・Current depth of water. It displays by 0.1m unit starting from 1.5m. *Maximum 99.9m.
  • Page 28: Current Depth

    DIVE MODE (DIVE) ■Basic screen No-decompression limit Basic screen of Dive Mode displays the following Elapsed dive time information  ・Elapsed dive time (Minutes) Current depth  ・No-decompression limit (Minutes)  ・Current depth  ・Tissue loading bar graph (TLBG) Tissue Loading Bar Graph Oxygen Accumulation (O2) or  ・Oxygen accumulation (O2) or (TLBG) Partial Pressure of Oxygen...
  • Page 29 DIVE MODE (DIVE) ■Depress M button to display digital compass reading screen. Current Time Digital compass reading screen displays the Direction Indicator following information.  ・Current time  ・Direction  ・Angle value Angle Value Depress P button for remeasurement. Depress M button to return to the basic screen. Please refer to page 60 as to directionreading.
  • Page 30: Safety Stop

    DIVE MODE (DIVE) ■Depress L button to display watch screen. Seconds Date Watch screen displays the following information.  ・Date  ・Seconds Time  ・Hour  ・Minutes Watch screen is displayed for 1 minute. After 1 minute, it goes back to the basic screen automatically.
  • Page 31 DIVE MODE (DIVE) When you ascend in a no-decompression diving condition after having descended to the depth deeper than 10m, 3-minute timer starts automatically from the depth of 6.5m and continues while you stay at the depth of 1.5m to 9.9m. We recommend that you perform “Safety Stop” until the 3-minute countdown is completed without ascending to the surface of the water.
  • Page 32: Surface Mode

    DIVE MODE (DIVE) Surface Mode Surface Mode is a display mode when residual nitrogen is still in the body tissue after diving. Desaturation Time Surface Interval Time Airplane Boarding Prohibition Indicator Current Time Tissue Loading Bar Graph Oxygen Accumulation (O2) or (TLBG) Partial Pressure of Oxygen (PO2) Bar Graph...
  • Page 33: Repetitive Diving

    DIVE MODE (DIVE) ●When nitrogen and oxygen remaining in the body tissue disappear, Surface Mode returns to Watch Mode automatically. ●Even a state with nitrogen and oxygen remaining in the body tissue, when it passes for 48 hours, the screen returns to the Watch Mode automatically. ●Airplane boarding prohibition indicator continues turning on for 24 hours after diving.
  • Page 34: Nitrox (Eanx) Diving

    DIVE MODE (DIVE) Nitrox (EANx) Diving ●EANx : Enriched Air Nitrox (Abbr. : Nitrox) The mixed gases which raised a ratio of oxygen than compressed air (Fraction of oxygen 21%) of usually use You can use this product to the diving using usually use compressed air with 21 % fraction of oxygen and EANx with 22 to 50% fraction of oxygen.
  • Page 35: Dive Mode (Decompression Dive)

    DIVE MODE (DECOMPRESSION DIVE) Dive Mode (Decompression Dive) Decompression Dive Warning The warning activates when the no-decompression time is exceeded and decompression stop becomes necessary. DECO Mark No-decompression Limit Elapsed Dive Time Current Depth Tissue Loading Bar Graph (TLBG) 1)DECO Mark lights up, Tissue Loading Bar Graph (TLBG) and Current Depth fl ash. 2)Alarm sounds for 6 seconds.
  • Page 36: Decompression Dive (Before Decompression Stop)

    DIVE MODE (DECOMPRESSION DIVE) Decompression Dive (Before Decompression Stop) When the screen switches to Decompression Dive (Before Decompression Stop), decompression stop depth is displayed. It displays the depth every 3m depending on the diving situation. (Decompression stop depth display, 3~33m) At the time of decompression dive (Before decompression stop), it displays the following information.
  • Page 37 DIVE MODE (DECOMPRESSION DIVE) ■Decompression Dive Screen (Before Decompression Stop) Decompression Stop Decompression dive basic screen of Dive Mode Depth (Before decompression stop) displays the Elapsed Dive Time following information.  ・Elapsed dive time (Minutes)  ・Decompression stop depth  ・Current depth  ・Tissue loading bar graph (TLBG)  ・Oxygen accumulation (O2) or partial Current Depth pressure of oxygen (PO2) bar graph...
  • Page 38 DIVE MODE (DECOMPRESSION DIVE) ■Depress A button to display maximum depth Current Water Temperature screen. Total Ascent Time Maximum depth screen displays the following information.  ・Current water temperature ・Total ascent time (TOTAL) ・Maximum depth Display goes back to the decompression dive basic screen (Before decompression stop)in 4 Maximum Depth seconds automatically.
  • Page 39: Decompression Dive (Under Decompression Stop)

    DIVE MODE (DECOMPRESSION DIVE) ■Depress L button to display watch screen. Seconds Date Watch screen displays the following information.  ・Date  ・Seconds Time  ・Hour  ・Minutes Watch screen is displayed for 1 minute. After 1 minute, it goes back to the decompression dive basic screen (Before decompression stop) automatically.
  • Page 40 DIVE MODE (DECOMPRESSION DIVE) At the time of decompression dive (Under decompression stop), it displays the following information. ○Decompression Stop Depth・・・・・Decompression stop depth is displayed every 3m depending on the diving situation. ○Decompression Stop Timer・・・・・ It displays the time necessary for decompression stop. ○DECO・・・・・・・・・・・・・・...
  • Page 41 DIVE MODE (DECOMPRESSION DIVE) ■Decompression Dive Screen Elapsed Dive Time Decompression (Under Decompression Stop) Stop Timer Decompression dive basic screen of Dive Mode (Under decompression stop) displays the following information.  ・Elapsed dive time (Minutes)  ・Decompression stop timer (Minutes)  ・Decompression stop depth Current Depth  ・Current depth  ・Tissue loading bar graph (TLBG)
  • Page 42 DIVE MODE (DECOMPRESSION DIVE) ■ Depress A button to display maximum depth Current Water Temperature screen. Total Ascent Time Maximum depth screen displays the following information. ・Current water temperature ・Total ascent time (TOTAL) ・Maximum depth Display goes back to the decompression dive Maximum Depth basic screen (Under decompression stop) in 4 seconds automatically.
  • Page 43 DIVE MODE (DECOMPRESSION DIVE) ■ Depress L button to display watch screen. Seconds Watch screen displays the following information. Date ・Date ・Seconds ・Hour Time ・Minutes Watch screen is displayed for 1 minute. After 1 minute, it goes back to the decompression dive basic screen (Under decompression stop) automatically.
  • Page 44: Warning While Diving

    WARNING WHILE DIVING Warning While Diving Ascent Rate Warning It monitors ascent rate and gives warning when the ascent rate exceeds the specifi ed rate. The specifi ed rate is 10m/minute. No-decompression Limit Elapsed Dive Time Ascent Rate Warning (SLO) ●When the ascent rate exceeds 10m/minute, warning of “SLO”...
  • Page 45: Decompression Stop Violation Warning

    WARNING WHILE DIVING Decompression Stop Violation Warning When you are in the depth within the range of -0.5<Decompression stop depth<+1.0m, it performs countdown. When the depth becomes -0.5m less than the decompression stop depth while under decompression stop, it gives warning.
  • Page 46: High Oxygen Accumulation Alarm (High O2 Alarm)

    WARNING WHILE DIVING High Oxygen Accumulation Alarm (High O2 Alarm) The warning activates when the oxygen accumulation exceeds acceptable range. 1. Oxygen accumulation (O2) and partial pressure of oxygen (PO2) bar graph fl ash. 2. Alarm sounds for 6 seconds. 3.
  • Page 47: Violation Gauge Warning

    WARNING WHILE DIVING Violation Gauge Warning Violation gauge warning activates when applied to the following conditions; When the depth exceeds 99.9m. When the elapsed dive time exceeds 599 minutes. When decompression is needed at the depth of deeper than 33m while decompression diving. When decompression stop time or total ascent time exceeds 99 minutes, while decompression diving.
  • Page 48: Log Mode (Log)

    LOG MODE ( LOG ) Log Mode Watch Mode Surface Mode A Button L Button P Button M Button (for more than 2 seconds)
  • Page 49: Enter The Log Mode

    LOG MODE ( LOG ) Log can be used in Watch Mode and Surface Mode. It displays logs of 30 dives from the newest one. Since a simple diving profile can be checked, you can get to know the depth change according to the dive time elapsed.
  • Page 50: Check A Log

    LOG MODE ( LOG ) Check a Log Log consists of five screens. ○LOG Log No. ・・・Number is given to each dive in order. Dive date・・・Year, month and date of dive. Dive No.・・・Number showing the order of diving on the day. Entry time・・・Time dive started.
  • Page 51: Button Operation

    LOG MODE ( LOG ) Button Operation ■ LOG When you enter the Log Mode, the newest diving log is displayed. Log No. Log screen displays the following information. ・Log No. Alternate display of ・Dive date Dive No. year/month and date ・Dive No.
  • Page 52 LOG MODE ( LOG ) ■ L-2 L-2 screen displays the following information. Average Depth ・Maximum depth Maximum Depth ・Average depth ・Warning occurred Depress A button to display “L-3” screen. ●When it displays the depth in the Log Mode, if the depth is less than 50m, it becomes 0.2m unit, and is deeper than 50m, it becomes 0.4m unit.
  • Page 53 LOG MODE ( LOG ) ■ L-3 L-3 screen displays the following information. ・Fraction of oxygen used Depress A button to display “PROF” screen. Fraction of Oxygen Used...
  • Page 54 LOG MODE ( LOG ) ■ Dive Profi le (PROF) Time Graph Ended Dive profi le (PROF) screen displays the Graph Time Graph Started following information. ・Time graph ended ・Graph ・Alternate display of time graph started and maximum depth. Depress A button to display “LOG” screen. Alternate Display of Depth and Time ●Whenever you depress the P button, data is updated at intervals of 30 seconds, and the time graph started and the time graph ended progress.
  • Page 55: Check A History

    LOG MODE ( LOG ) Check a History Total Dive Time Total Number of Dive Maximum Depth 1. Enter the Log Mode. ・Depress L button once at the time of Watch Mode or Surface Mode. ・”LOG” is displayed on a screen and it switches to Log Mode in about 1 second. ・The newest log is displayed when it switches to Log Mode.
  • Page 56: Plan Mode (Plan)

    PLAN MODE ( PLAN ) Plan Mode In Plan Mode, no-decompression limit corresponding to the safety factor in compressed air and Nitrox (EANx) diving can be checked. Setup of fraction of oxygen (FO2) and the safety factor is performed in Plan Mode. No-decompression Limit Scheduled Dive Depth Check a Plan...
  • Page 57: Safety Factor Setting

    PLAN MODE ( PLAN ) Safety Factor Setting Safety factor can be selected from 3 steps of levels. Default value is SF- 0. The safety factor becomes high in order of SF- 0, SF-1 and SF-2. Safety Factor Fraction of Oxygen (FO2) 1.
  • Page 58: Fraction Of Oxygen (Fo2) Setting

    PLAN MODE ( PLAN ) Fraction of Oxygen (FO2) Setting 1. Enter the Plan Mode. ・Depress P button once at the time of Watch Mode or Surface Mode. ・”PLAN” is displayed on a screen and it switches to Plan Mode in about 1 second. 2.
  • Page 59: Altitude Diving And Fresh Water Diving

    ALTITUDE DIVING AND FRESH WATER DIVING Warning ●When performing altitude diving, no-decompression limit (NDL) becomes shorter than the one at sea level of 0m. Please reconfirm NDL in the low state of barometric pressure which passed 15 minutes or more after you ascend to the high place. Otherwise, you may get decompression sickness.
  • Page 60: Direction Reading (Comp)

    DIRECTION READING ( COMP ) It measures direction with the bearing sensor built in this product. Direction abbreviations (16 directions) and angle value are displayed. ・In order to measure correctly, please refer to “Calibrate Bearing Sensor” and “Precautions at Digital Compass Measurement”. ・It can be used in Watch Mode, Surface Mode and Dive Mode.
  • Page 61: Digital Compass Measurement

    DIRECTION READING ( COMP ) Digital Compass Measurement 1. When you depress M button once at the time of Watch Mode or Surface Mode, it switches to Digital Compass Mode. ・”COMP” is displayed and it switches to Digital Compass Mode in about 1 second. 2.
  • Page 62 DIRECTION READING ( COMP ) ■Bidirectional Calibration 1.Continue to depress A button for more than 2 seconds in Digital Compass Mode. ・Release the button if “CALIBRATION” “-1-“ is displayed after “SET” “Hold” flashes “CALIBRATION” is displayed as flowing. 2. epress L button. ・It starts to calibrate the first direction.
  • Page 63: Precautions At Digital Compass Measurement

    DIRECTION READING ( COMP ) Precautions at Digital Compass Measurement ●Magnetic north and True north. True North There are two kinds of geography terms showing north, magnetic north Magnetic North and true north. ・Magnetic north : north which compass (bearing magnetic needle) indicates. West East ・True north : the direction of the North Pole point.
  • Page 64: Stopwatch (Stw)

    STOPWATCH ( STW ) The stopwatch measures elapsed time up to 999 hours, 59 minutes, 59.9 seconds by 1/10 second unit. When a measuring range is exceeded, it returns to 0 and continues measurement. Stopwatch can be used at the time of Watch Mode and Surface Mode. Current Time Hour 1/10 Second...
  • Page 65: Time Measurement

    STOPWATCH ( STW ) Time Measurement ■ To perform an elapsed time operation P button P button L button P button P button Restart Stop Reset Start Stop ■ To pause at a split time L button L button L button P button L button Reset release...
  • Page 66: Timer (Tmr)

    TIMER (TMR) You can set up a timer from 1 minute to 24 hours. When it reaches the time you selected, time up alert sounds for 10 seconds. Timer can be used at the time of Watch Mode and Surface Mode. Current Time Hour Minutes...
  • Page 67: Setting A Timer

    TIMER (TMR) Setting a Timer 1. Continue to depress A button for more than 2 seconds.  ・Release the button if “Hour” display of Timer flashes after “SET” “Hold” flashes, 2. Depress M button to select “Hour” or “Minutes”. ・The one you selected flashes. 3.
  • Page 68: Alarm・Hourly Time Signal (Alm)

    ALARM / HOURLY TIME SIGNAL (ALM) Four usual alarms and one snooze alarm can be set up. In the case of usual alarm, when the time reaches the time preset, alarm sounds for about 10 seconds. In the case of snooze alarm, when the time reaches the time preset, alarm sounds for about 10 seconds, and repeats it 7 times in every 5 minutes.
  • Page 69: Setting An Alarm Time

    ALARM / HOURLY TIME SIGNAL (ALM) Setting an Alarm Time 1. Depress P button (UP) or L button (DOWN) to find alarm number to set up while in Alarm Mode. P button AL-3 AL-1 AL-2 L button AL-4 ( Snooze ) ( Time Signal ) 2.
  • Page 70: Turn Alarm On And Off

    ALARM / HOURLY TIME SIGNAL (ALM) Turn Alarm On and Off 1. Depress P button (UP) or L button (DOWN) to find alarm number to set up while in Alarm Mode. 2. Depress A button to turn alarm or time signal on and off. ・When any alarm (one or multiple among five) is turned on, “ALM”...
  • Page 71: World Time (Wt)

    WORLD TIME ( WT ) You can view the current time in one of 48 cities (31 time zones) around the world. The city that is selected in the World Time Mode is called the “World Time City”. Please refer to City Code Table as to the City Code. (p. 88) Selected World Time City Current Time Summer Time...
  • Page 72: View The Time In Another Time Zone

    WORLD TIME ( WT ) View the Time in Another Time Zone Depress P button (UP) or L button (DOWN) to select a City Code while in World Time Mode. ・It displays current time of the selected city. ・Continue to depress P button or L button for fast forward. Summer Time (DST) Setting 1.
  • Page 73: Barometric Pressure And Temperature (Baro)

    BAROMETRIC PRESSURE AND TEMPERATURE (BARO) It displays current barometric pressure and temperature. Temperature Barometric Pressure (hPa) Barometric Pressure and Temperature Measuring While in the Watch Mode or the Surface Mode, depress M button six times to enter the Barometer/Thermometer Mode. ・”BARO”...
  • Page 74: Illumination

    ILLUMINATION The display is illuminated for easy reading in the dark. Also, auto light switch turns on illumination automatically when you angle it in the dark. ●Turn on illumination manually. P Button M Button ・Depress B button to turn on illumination. Illumination is disabled while an alarm is sounding.
  • Page 75: Turn The Auto Light Switch On And Off

    ILLUMINATION Turn the Auto Light Switch On and Off While in the Watch Mode or the Surface Mode, continue to depress B button for more than 3 seconds. ・Dot display indicates “LT” while the auto light switch is turned on. ・Dot display indicates “OFF”...
  • Page 76: Other Settings

    OTHER SETTINGS Other than time settings, you can change the following settings. ・Button operation tone ・Illumination duration ・Turn power saving on and off ・Unit setting ・DISP screen setting 12/24 Hour SUMMER TIME Home City Seconds ( DST ) Format DISP Hour Screen Unit...
  • Page 77: Turn The Button Operation Tone On And Off

    OTHER SETTINGS Turn the Button Operation Tone On and Off You can turn the button operation tone on or off as desired. 1. While in the Watch Mode or the Surface Mode, continue to depress A button for more than 2 seconds.
  • Page 78: Illumination Duration Setting

    OTHER SETTINGS Illumination Duration Setting You can select the illumination duration. 1. While in the Watch Mode or the Surface Mode, continue to depress A button for more than 2 seconds.  ・Release the button when a City Code and its city name are displayed as flowing following the display of “CITY”...
  • Page 79 OTHER SETTINGS DISP Screen Setting You can set up DISP screen. You can select “Current Depth” or “No-decompression Limit” as the basic screen of Dive Mode. 1. While in the Watch Mode or the Surface Mode, continue to depress A button for more than 2 seconds.
  • Page 80: Unit Setting

    OTHER SETTINGS Unit Setting You can change unit of temperature and depth when you set the Home City in any place other than Tokyo (TYO). When you select Tokyo (TYO) as the Home City, you cannot change the unit. The unit of temperature is Celsius and the one of depth is meter when you select Tokyo (TYO) as the Home City.
  • Page 81: Troubleshooting

    TROUBLESHOOTING SITUATIONS CAUSES AND MEASURES Display is weak. At the time of low temperature, display may become weak. Please leave it as it is to see how it is going for a while. When a situation does not improve, please consult with your original dealer. Inside of the glass When cooled suddenly, the inside of glass may mist.
  • Page 82 TROUBLESHOOTING SITUATIONS CAUSES AND MEASURES The current time Your Home City setting may be wrong. Check your Home City setting. display is off by hours. Please refer to “Home City and Summer Time Setting” (Page 21). The current time Check your summer time (DST) setting and adjust it if necessary. display is off by one Please refer to “Home City and Summer Time Setting”...
  • Page 83 TROUBLESHOOTING SITUATIONS CAUSES AND MEASURES Different compass Magnetism generated by nearby high-tension wires is interfering with measurements give detection of terrestrial magnetism. Move away from the high-tension different results at the wires and try it again. same place. TV, personal computer, speakers, or some other object is interfering Correct compass with terrestrial magnetism detection.
  • Page 84: Maintenance

    MAINTENANCE ■How to maintain this product. You wear a Dive Computer directly on your body like clothing. In order to use it for a long time, please wipe off any dirt, sweat and water, etc. frequently with a soft cloth. Use this product by keeping it always clean.
  • Page 85: Service After The Sales

    SERVICE AFTER THE SALES ■Precautions when you ask for repair. ・ As the all log data currently recorded in the product may be eliminated when it is repaired, please copy the data in a logbook etc. ・ When you send it to repair, please specify your request of repair, your name, your address and telephone number, and send it to your original dealer.
  • Page 86: Specifications

    SPECIFICATIONS □ Time accuracy : ±15 seconds a month Basic functions : Hour, minutes, seconds, year, month, day, day of the week, a.m./p.m. (P), 24- hour format, full auto-calendar (up to year 2099) □ Sensor precision Bearing sensor Within ±10° Temperature sensor : Within ±2℃...
  • Page 87 SPECIFICATIONS □ Alarm : Time alarm 4usual alarms 1 snooze alarm Setting unit : Hour, minutes Alarm sounds for 10 seconds. Hourly time signal : Electronic sound reports twice every hour on the hour. □ Other : LED light. Selectable illumination duration. Full Auto Light. Power Saving Battery power indicator.
  • Page 88: City Code Table

    CITY CODE TABLE Please confirm the time zone you need on the map. UTC Offset / GMT Differential City Code Table City Code City UTC Offset / GMT Differential Lisbon London Madrid Paris Rome Berlin Stockholm Athens Cairo...
  • Page 89 CITY CODE TABLE City Code City UTC Offset / GMT Differential Jerusalem Moscow Jeddah Tehran +3.5 Dubai Kabul +4.5 Karachi Delhi +5.5 Kathmandu +5.75 Dhaka Yangon +6.5 Bangkok Singapore Hong Kong +8 Beijing Taipei Seoul Tokyo Adelaide +9.5 Guam Sydney Noumea Wellington Pago Pago...
  • Page 90 CITY CODE TABLE City Code City UTC Offset / GMT Differential St. Johns -3.5 Rio De Janeiro Fernando de Noronha Praia ●As of December, 2012, though the time difference (UTC offset) of Moscow has been changed to “+4”, it does not correspond with this product. Please use it by setting summer time (DST) forward for 1 hour.
  • Page 91 memo...
  • Page 92 memo...
  • Page 93 memo...
  • Page 94 memo...
  • Page 95 memo...
  • Page 96 memo...
  • Page 97 memo...
  • Page 98 memo...
  • Page 99 memo...

Table of Contents