One-Touch™ Test Mode
To speed up installation and testing, One-Touch™ testing is provided which allows the controller
functionality to be tested at the controller or reader.
Test
Normal Operation
One-Touch™ View
Mode
One-Touch™ Active
Mode
Reader and Request to
Exit Test
Auxiliary and Lock
Relays Test
Tamper and Override
Test
RS-232 Test
(PAC 512 only)
Leave One-Touch™
Active Test mode
17474v4.0
Action
Hold down the One-Touch™
button for less than 2 seconds.
Present keys and press RTE
switches and observe LEDs.
Automatically exits after 2 minutes
Hold down the One-Touch™
button for 2 to 4 seconds.
Present a key to each reader (the
lock will activate).
Press the Request to Exit switch
(the lock will activate).
Open the door contact.
Present a key to a reader, press the
Request to Exit switch and open
the door contact simultaneously.
Remove link to 0V on tamper or
open circuit tamper switch.
Remove link to 0V on emergency
override or leave open circuit
tamper switch.
Remove the link between TAMP
and 0V on the Tamper & Override
terminal block.
Remove the link between OVRD
and 0V on the Tamper & Override
terminal block.
Link Tx and Rx on the RS-232
terminal block.
Hold down the One-Touch™
button for less than 2 seconds.
One-Touch™ Test mode will
automatically be timed out after 1
hour and on power down and up.
Observation
Controller
The green system
status LED flashes
at normal rate.
Door status LEDs
off.
The green system
status LED flashes
at normal rate.
Green on -valid key
has been
Red on - door open
presented to
Yellow on - RTE
reader
switch has been
Green flash -
pressed
invalid key has
been presented to
reader
The green system
status LED flashes
faster than normal.
The door green
LED flashes once
for SIGA, twice for
SIGB.
The door green
LED flashes three
times and the
yellow LED is lit.
The door green
LED flashes four
times and the red
LED is lit.
The appropriate auxiliary relay is activated.
Both auxiliary relay is activated.
The auxiliary relay is activated.
The auxiliary relay is activated but the door relays are uneffected.
Both auxiliary and lock relays are activated, the door opens and the lock operates.
The red and
green RS-232
LEDs are lit.
The green
system status
LED returns to
its normal flash
rate.
Reader
The normal operation
of the reader.
The normal operation
of the reader LED
changes, e.g. if
default is red, it turns
green.
The reader LED
flashes once for
SIGA, twice for SIGB.
The reader LED
flashes three times.
The reader LED
flashes four times.
There is no effect at the
reader.
The reader LED returns to
its normal operation.
5