Specifications/Performance - Honeywell IPT User Manual

Table of Contents

Advertisement

2.2 Specifications/Performance

Total Error Band
Supply Voltage
Current Consumption
Operating Temperature Range
Storage Temperature Range
Sample Rate
Long Term Stability
Pressure Ranges/Type
Pressure Units
Media Compatibility
(3)
Weight
Size
Interface
Output
Overpressure
Burst Pressure
Humidity Sensitivity of Pressure Ports
Electromagnetic Immunity/Emissions
Mechanical Shock
Thermal Variation
Vibration
ESD
RoHS Compliant (2011/65/EU)
(1)
Total Error is the sum of worst case linearity, repeatability, hysteresis, thermal effects, and calibration errors over the operating
temperature range. Accuracy is only achieved after applying the correction coefficients and algorithm as shown in section 3.2. (FS =
Full Scale) For total error calculations of differential units, "Full Scale" is the pressure difference between the minimum and maximum
pressures. For example, full scale for a 1 psid PPT is 2 psi (-1 to +1 psi).
(2)
After applying the correction coefficients stored in EEPROM, the resultant pressure reading is expressed in PSI (pounds per square
inch).
(3)
Not including any mounting hardware. Dimensions in section 2.3 do not include Humiseal 1A33 conformal coating which is typically
applied to the PWB assembly at a thickness of 1-3 mils.
(4)
Operation with a digital interface > 3.3V can damage the IPT and cause shifts in the ADC output.
(5)
IPT electronics require protection from humidity.
(6)
IPT requires shielding from EMI.
(1)
±0.04%FS absolute
±0.10%FS gauge, differential
±0.20%FS 1 psi gauge
4 to 12 VDC
6 mA typical, 7.5 mA max
-40 to 85°C (-40 to 185°F)
-55 to 125°C (-67 to 257°F)
See section 3.1.2
0.025%FS max per year typical
20, 50 psia
1, 2, 5, 10, 20 psig
1, 2, 5, 10, 20 psid
(2)
PSI
Non-condensing, non-corrosive,
non-combustible gases
~ 8.0 grams (absolute)
~ 9.7 grams (gauge, differential)
(3)
See section 2.3
(4)
3.3V SPI (mode 1,1)
SCLK ≤ 5 MHz
24-bit pressure value
16-bit temperature value
256 x 8 EEPROM configuration
3X FS
3X FS
DO-160E, Section 6.0, category A
(6)
DO-160E Section 7.0, Category A,
Figure 7.2, Operational Standard
Storage Temperature Cycling per
JESD22-104, Section 5.0: -55°C to
+125°C,
DO-160E Section 8, Category H,
Aircraft Type 2, Aircraft Zones 1 & 2.
Class 3A, Table III, MIL-STD-883G,
Method 3015.7, section 3.4
Yes
(5)
5